{"product_id":"fluke-fluke-922-airflow-meter-250-to-16000-ft-per-min","title":"Fluke FLUKE-922 Airflow Meter 250 to 16000 Ft Per Min","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FLUKE FLUKE-922 is a handheld airflow meter designed for HVAC professionals who need accurate velocity and pressure readings across a wide measurement range. It captures air velocity from 250 to 16,000 feet per minute and measures both airflow and differential pressure in a single instrument. Built-in humidity sensing and a data logging function make it suitable for commissioning, balancing, and diagnostic work on air distribution systems. The unit operates across a process temperature range of 32 degrees F to 122 degrees F. Auto power off extends battery life during long service days. Weighing 1.68 pounds, it is light enough for extended single-hand use on ladders and in tight mechanical spaces.\u003c\/p\u003e\u003cp\u003eThe FLUKE-922 is used in commercial and residential HVAC applications where duct balancing, air handler performance verification, and ventilation compliance testing are required. It is well suited for TAB (testing, adjusting, and balancing) work, exhaust fan performance checks, filter static pressure drop measurements, and fume hood velocity verification. The dual-port pitot-tube input accepts the included rubber hoses for differential pressure readings, making it a practical tool for technicians who need both velocity and static pressure data without carrying separate instruments.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAir velocity range of 250 to 16,000 feet per minute for wide coverage across residential and commercial duct systems\u003c\/li\u003e\n\u003cli\u003eDifferential pressure measurement alongside airflow in one device\u003c\/li\u003e\n\u003cli\u003eBuilt-in humidity sensing with 2.5% accuracy\u003c\/li\u003e\n\u003cli\u003eData logging capability for recording and comparing readings across multiple test points\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy of 1% over a 32 degrees F to 122 degrees F operating range\u003c\/li\u003e\n\u003cli\u003eAuto power off function preserves battery life during intermittent use\u003c\/li\u003e\n\u003cli\u003eCE Certified and N10140 listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use with pitot tube-style airflow measurement setups in HVAC duct systems. Includes two rubber hoses for differential pressure port connections. Compatible with standard pitot tube probes used in duct traversal and static pressure testing applications.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation and use should be performed by a qualified HVAC technician or TAB professional familiar with air measurement procedures. Before connecting hoses to pressure ports, ensure the system fan is off and duct access points are safely accessible. Follow the included users manual for zeroing procedures and probe insertion technique to ensure accurate differential pressure readings. The FLUKE-922 is a measurement instrument, not a permanently installed component, so no wiring or power-down of electrical panels is required for normal field use.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Air Velocity\u003c\/strong\u003e: 250 feet per minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Air Velocity\u003c\/strong\u003e: 16,000 feet per minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Process Temperature\u003c\/strong\u003e: 32 degrees F (0 degrees C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Process Temperature\u003c\/strong\u003e: 122 degrees F (50 degrees C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e: 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Accuracy\u003c\/strong\u003e: 2.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasures\u003c\/strong\u003e: Airflow, Pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Sensing\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Power Off\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.68 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes\u003c\/strong\u003e: Fluke 922 Airflow Meter, (2) Rubber Hoses, (4) AA Batteries 1.5V Alkaline, Users Manual, Soft Carrying Case, Wrist Strap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE Certified, N10140\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUNSPSC Code\u003c\/strong\u003e: 41114400\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FLUKE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: FLUKE-922\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":51540879049010,"sku":"FLUKE-922","price":1237.52,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/6fe730f2220d6850653ce71dddc3ae9f.jpg?v=1785865260","url":"https:\/\/voomisupply.com\/products\/fluke-fluke-922-airflow-meter-250-to-16000-ft-per-min","provider":"Voomi Supply","version":"1.0","type":"link"}