{"product_id":"fluke-2538803-116-digital-hvac-multimeter","title":"Fluke 2538803 116 Digital HVAC Multimeter","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FLUKE 2538803 116 Digital HVAC Multimeter is designed for HVAC professionals to troubleshoot equipment. It features a built-in thermometer for temperatures up to 400°C (752°F) and microamps for flame sensor testing. This multimeter measures resistance, continuity, frequency, and capacitance. A large white LED backlight ensures visibility in poorly lit areas. It is independently tested for safe use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for HVAC professionals to troubleshoot equipment.\u003c\/li\u003e\n  \u003cli\u003eIncludes a built-in thermometer for temperature measurements up to 400°C (752°F).\u003c\/li\u003e\n  \u003cli\u003eProvides microamps to test flame sensors and measures resistance, continuity, frequency, and capacitance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis multimeter is designed for HVAC professionals, offering temperature measurement, flame sensor testing, and essential electrical measurements with CAT III 600 V safety.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FLUKE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 2538803\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Voltage to Earth Ground\u003c\/strong\u003e: 600 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay Type\u003c\/strong\u003e: Digital\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Display Counts\u003c\/strong\u003e: 6,000 counts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Display Update Rate\u003c\/strong\u003e: 4 per second\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBar Graph Segments\u003c\/strong\u003e: 33 segments\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBar Graph Update Rate\u003c\/strong\u003e: 32 per second\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -10°C to +50°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +60°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Type\u003c\/strong\u003e: 9 volt Alkaline, IEC 6LR61\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Life\u003c\/strong\u003e: 400 hours typical, without backlight\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Millivolts Range\u003c\/strong\u003e: 600.0 mV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Millivolts Resolution\u003c\/strong\u003e: 0.1 mV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Millivolts Accuracy\u003c\/strong\u003e: ±(0.5% + 2 counts)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Volts Range\u003c\/strong\u003e: 6.000 V, 60.00 V, 600.00 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Volts Resolution\u003c\/strong\u003e: 0.001 V, 0.01 V, 0.1 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Volts Accuracy\u003c\/strong\u003e: ±(0.5% + 2 counts)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Volts Range\u003c\/strong\u003e: 600.0 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Volts Resolution\u003c\/strong\u003e: 0.1 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Volts Accuracy (DC, 45-500 Hz)\u003c\/strong\u003e: 2.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Volts Accuracy (500 Hz-1 kHz)\u003c\/strong\u003e: 4.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Millivolts True RMS Range\u003c\/strong\u003e: 600.0 mV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Millivolts True RMS Resolution\u003c\/strong\u003e: 0.1 mV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Millivolts True RMS Accuracy (DC, 45-500 Hz)\u003c\/strong\u003e: 1.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Millivolts True RMS Accuracy (500 Hz-1 kHz)\u003c\/strong\u003e: 2.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Volts True RMS Range\u003c\/strong\u003e: 6.000 V, 60.00 V, 600.0 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Volts True RMS Resolution\u003c\/strong\u003e: 0.001 V, 0.01 V, 0.1 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Volts True RMS Accuracy (DC, 45-500 Hz)\u003c\/strong\u003e: 1.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Volts True RMS Accuracy (500 Hz-1 kHz)\u003c\/strong\u003e: 2.0% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuity Range\u003c\/strong\u003e: 600 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuity Resolution\u003c\/strong\u003e: 1 Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuity Detection\u003c\/strong\u003e: Beeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of 500 µs or longer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Range (Low)\u003c\/strong\u003e: 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Resolution (Low)\u003c\/strong\u003e: 0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Accuracy (Low)\u003c\/strong\u003e: 0.9% + 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Range (High)\u003c\/strong\u003e: 40.00 MΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Resolution (High)\u003c\/strong\u003e: 0.01 MΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOhms Accuracy (High)\u003c\/strong\u003e: 5% + 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiode Test Range\u003c\/strong\u003e: 2.00 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiode Test Resolution\u003c\/strong\u003e: 0.001 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiode Test Accuracy\u003c\/strong\u003e: 0.9% + 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance Range (Low)\u003c\/strong\u003e: 1000 nF, 10.00 µF, 100.0 µF, 9999 µF, 100 µF to 1000 µF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance Resolution (Low)\u003c\/strong\u003e: 1 nF, 0.01 µF, 0.1 µF, 1 µF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance Accuracy (Low)\u003c\/strong\u003e: 1.9% + 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance Range (High)\u003c\/strong\u003e: \u0026gt; 1000 µF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacitance Accuracy (High)\u003c\/strong\u003e: 5% + 20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLo-Z Capacitance Range\u003c\/strong\u003e: 1 nF to 500 µF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLo-Z Capacitance Accuracy\u003c\/strong\u003e: 10% + 2 typical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Range (°C)\u003c\/strong\u003e: -40°C to 400°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Resolution (°C)\u003c\/strong\u003e: 0.1°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy (°C)\u003c\/strong\u003e: 1% + 10\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Range (°F)\u003c\/strong\u003e: -40°F to 752°F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Resolution (°F)\u003c\/strong\u003e: 0.2°F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy (°F)\u003c\/strong\u003e: 1% + 18\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Microamps True RMS Range (45-500 Hz)\u003c\/strong\u003e: 600.0 µA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Microamps True RMS Resolution (45-500 Hz)\u003c\/strong\u003e: 0.1 µA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Microamps True RMS Accuracy (45-500 Hz)\u003c\/strong\u003e: 1.5% + 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Microamps Range\u003c\/strong\u003e: 600.0 µA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Microamps Resolution\u003c\/strong\u003e: 0.1 µA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Microamps Accuracy\u003c\/strong\u003e: 1.0% + 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Range (V or A input)\u003c\/strong\u003e: 99.99 Hz, 999.9 Hz, 9.999 kHz, 50.00 kHz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Resolution (V or A input)\u003c\/strong\u003e: 0.01 Hz, 0.1 Hz, 0.001 Hz, 0.01 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Accuracy (V or A input)\u003c\/strong\u003e: 0.1% + 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge Protection\u003c\/strong\u003e: 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Multimeter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\/Usage\u003c\/strong\u003e: HVAC Professional\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Ranging\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: 116F\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":51306908221746,"sku":"2538803","price":360.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309540446.jpg?v=1781302199","url":"https:\/\/voomisupply.com\/products\/fluke-2538803-116-digital-hvac-multimeter","provider":"Voomi Supply","version":"1.0","type":"link"}