{"product_id":"first-company-60hcxq4010apb00aaf-air-handler-5-ton-120v","title":"First Company 60HCXQ4010APB00AAF Air Handler 5 Ton 120V","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRST COMPANY 60HCXQ4010APB00AAF is a single-piece, multi-position hot water air handler rated at 5 nominal tons and designed for upflow and horizontal installations. It ships with a factory-installed circulating pump, automatic pump timer, and blower delay controls, making it a largely pre-assembled unit ready for field connection. The PSC motor operates on 120 volts with 24-volt control wiring, delivering a nominal airflow of 2,000 CFM. The slide-out hot water coil assembly and easy-access check valve simplify service calls. Licensed HVAC technicians install this unit in residential and light-commercial hydronic systems where forced-air distribution is paired with a hot water heat source.\u003c\/p\u003e\n\u003cp\u003eThis air handler is suited for hydronic heating applications in residential and light-commercial settings. The upflow and horizontal configuration options give installers flexibility in mechanical room layouts. The unit includes a convertible horizontal drain pan, primary and secondary drains, a factory-installed manual air purge valve, and a blower door safety switch. R-410A refrigerant compatibility makes it appropriate for cooling coil configurations within applicable system designs. No TXV is included with this unit. A factory-installed filter and 20-amp maximum fuse sizing round out the standard installation requirements.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory-installed circulating pump with automatic pump timer and blower delay controls\u003c\/li\u003e\n  \u003cli\u003ePSC motor rated at 120 volts with 24-volt control circuit\u003c\/li\u003e\n  \u003cli\u003eNominal 2,000 CFM airflow; 1,930 CFM high at 0.3 inches ESP\u003c\/li\u003e\n  \u003cli\u003eSlide-out hot water coil assembly for simplified coil removal and service\u003c\/li\u003e\n  \u003cli\u003eConvertible horizontal drain pan with primary and secondary drain connections\u003c\/li\u003e\n  \u003cli\u003eEasy-access check valve and factory-installed manual air purge valve\u003c\/li\u003e\n  \u003cli\u003eBlower door safety switch included; factory-installed filter standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation air handler for upflow and horizontal multi-position hydronic forced-air systems compatible with R-410A refrigerant.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation instructions. Disconnect and lock out all electrical power before beginning any wiring or service work on the unit. Ensure hydronic supply and return lines are properly flushed before connecting to the factory-installed pump to prevent debris damage. Verify that supply voltage matches the 120-volt motor requirement and that circuit protection does not exceed the 20-amp maximum fuse size.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Tons\u003c\/strong\u003e: 5 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Type\u003c\/strong\u003e: PSC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmps at 240V\u003c\/strong\u003e: 8 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Amps\u003c\/strong\u003e: 16 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Fuse Size\u003c\/strong\u003e: 20 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal CFM\u003c\/strong\u003e: 2,000 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCFM at 0.5 inches ESP\u003c\/strong\u003e: 1,820 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCFM High at 0.3 inches ESP\u003c\/strong\u003e: 1,930 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Upflow \/ Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTXV Included\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Connection\u003c\/strong\u003e: 1\/2 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction Fitting\u003c\/strong\u003e: 7\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 52 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 25.25 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 26.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 270 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRST COMPANY\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 60HCXQ4010APB00AAF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRST COMPANY","offers":[{"title":"Default Title","offer_id":51347425296690,"sku":"60HCXQ4010APB00AAF","price":11686.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/renderImage_bbcf46f3-976c-47c5-a260-541dcd83157f.jpg?v=1782104567","url":"https:\/\/voomisupply.com\/products\/first-company-60hcxq4010apb00aaf-air-handler-5-ton-120v","provider":"Voomi Supply","version":"1.0","type":"link"}