{"product_id":"first-company-413005-30hx5-hx-series-dx-air-handler-30000-btu-h","title":"First Company 413005 30HX5 Hx Series Dx Air Handler 30000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRST COMPANY 413005 30HX5 is a horizontal ceiling-mount direct-expansion air handler from the HX Series, rated at 30,000 BTU\/h cooling capacity and designed for operation on a 240-volt power source. The unit uses R-410A refrigerant and features a permanent split capacitor (PSC) blower motor, aluminum fin coil construction with copper tubing, and a 3\/8-inch liquid line connection paired with a 7\/8-inch suction line. It ships ready for installation with a 20 x 20 x 1 inch filter. Licensed HVAC technicians install and service this unit as part of a split-system cooling installation.\u003c\/p\u003e\n\u003cp\u003eThis air handler is intended for horizontal ceiling applications in residential and light commercial settings where overhead unit placement is required. The HX Series configuration suits confined-space installations such as attic platforms, dropped ceilings, and suspended ceiling framing. The 30,000 BTU\/h capacity positions this unit for spaces typically in the 1,200 to 1,500 square foot range depending on local load calculations. It is matched with a compatible outdoor condensing unit and refrigerant line set sized to the factory-specified connections.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e30,000 BTU\/h cooling capacity for mid-size residential or light commercial spaces\u003c\/li\u003e\n  \u003cli\u003e240-volt power source with 25\/30-amp fuse requirement\u003c\/li\u003e\n  \u003cli\u003eR-410A refrigerant system — no ozone-depleting refrigerants\u003c\/li\u003e\n  \u003cli\u003ePermanent split capacitor blower motor for reliable, efficient airflow\u003c\/li\u003e\n  \u003cli\u003eAluminum fin and copper tubing coil construction for durable heat transfer\u003c\/li\u003e\n  \u003cli\u003e3\/8-inch liquid line and 7\/8-inch suction line connections for standard line set compatibility\u003c\/li\u003e\n  \u003cli\u003eIncludes 20 x 20 x 1 inch filter for immediate field installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style horizontal ceiling DX air handler for use with R-410A split-system condensing units. Refer to the manufacturer sizing and matchup documentation to confirm compatible outdoor unit pairings before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and EPA Section 608 refrigerant handling regulations. De-energize the circuit and lock out the disconnect before beginning any work on the unit. Ensure the ceiling or platform structure can support the weight of the fully installed handler, and verify that refrigerant line set sizing matches the factory-specified 3\/8-inch liquid and 7\/8-inch suction connections. Do not pressurize the refrigerant circuit without a proper nitrogen leak check and system evacuation per manufacturer procedures.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e: 30,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Source\u003c\/strong\u003e: 240 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Rating\u003c\/strong\u003e: 25\/30 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Line Size\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction Line Size\u003c\/strong\u003e: 7\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Size\u003c\/strong\u003e: 20 x 20 x 1 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Permanent Split Capacitor (PSC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil Construction\u003c\/strong\u003e: Aluminum fin with copper tubing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e: Horizontal ceiling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRST COMPANY\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 413005 30HX5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRST COMPANY","offers":[{"title":"Default Title","offer_id":51621073944882,"sku":"413005 30HX5","price":1010.38,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/ebc886e2b4760724672430e8eb81744d_1308ea95-1f83-4957-9889-1f101a9ba7b7.jpg?v=1787349305","url":"https:\/\/voomisupply.com\/products\/first-company-413005-30hx5-hx-series-dx-air-handler-30000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}