{"product_id":"eaton-fh86-a200-b100-heater","title":"Eaton FH86 A200\/B100 heater","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Eaton FH86 A200\/B100 heater is designed for use with A200 starter sizes 3 and 4, and is compatible with 3-phase systems. This A200 heater features a NEMA design and provides both thermal and fast trip functionality. It supports ambient full load current range of 74-78A and non-comp full load current range of 68-72A.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUsed with A200 Starter Sizes 3 \u0026amp; 4, 3-Phase Only\u003c\/li\u003e\n  \u003cli\u003eNEMA design\u003c\/li\u003e\n  \u003cli\u003eThermal and fast trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe Eaton FH86 heater is ideal for thermal overload protection in magnetic motor starters and motor controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: EATON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: FH86\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Malaysia\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number\u003c\/strong\u003e: FH86\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 786678671024\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 2.1 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 0.8 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 1.3 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CSA Certified  UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Catalog\u003c\/strong\u003e: FH86\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Heater\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial features\u003c\/strong\u003e: Used with A200 Starter Sizes 3 \u0026amp; 4, 3-Phase Only\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: A200 Heater\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed with\u003c\/strong\u003e: Used with A200 Starter Sizes 3 \u0026amp; 4, 3-Phase Only\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDesign\u003c\/strong\u003e: NEMA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull load current range\u003c\/strong\u003e: Ambient 74-78 A, Non-Comp 68-72 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverload relay\u003c\/strong\u003e: Type A and B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip type\u003c\/strong\u003e: Thermal and fast trip\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Eaton Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily\u003c\/strong\u003e: A200 Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Overload Relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart #\u003c\/strong\u003e: FH86\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Eaton\/Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: A200\/B100\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 68-72\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL, CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e: Thermal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength (in)\u003c\/strong\u003e: 2.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth (in)\u003c\/strong\u003e: 1.3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight (in)\u003c\/strong\u003e: 0.8\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: A200 Starter Sizes 3 and 4, 3-Phase, Thermal Overload Relays, Magnetic Motor Starters and Motor Controls\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: NEMA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNema Size\u003c\/strong\u003e: 3, 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMpn\u003c\/strong\u003e: FH86\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGtin\u003c\/strong\u003e: 786678671024\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"EATON","offers":[{"title":"Default Title","offer_id":51149551501618,"sku":"FH86","price":101.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305955970.jpg?v=1778596843","url":"https:\/\/voomisupply.com\/products\/eaton-fh86-a200-b100-heater","provider":"Voomi Supply","version":"1.0","type":"link"}