{"product_id":"eaton-faz-c0-5-3-na-faz-branch-protector-0-5a","title":"Eaton FAZ-C0.5\/3-NA FAZ Branch Protector 0.5A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe EATON FAZ-C0.5\/3-NA is a FAZ branch protector, which is a UL 489 industrial miniature circuit breaker. This three-pole supplementary protector is suitable for applications where medium levels of inrush current are expected. It features screw terminals and a C curve for circuit protection.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for medium inrush startup currents to protect small transformers and pilot devices.\u003c\/li\u003e\n  \u003cli\u003eFeatures a visual trip indicator and a common trip mechanism for enhanced operational safety.\u003c\/li\u003e\n  \u003cli\u003eMounts onto standard DIN rail systems, ideal for high-density industrial control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe EATON FAZ-C0.5\/3-NA branch protector provides precise thermal-magnetic protection for commercial applications. It has a 10kA interrupting rating at 480Y\/277VAC.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: EATON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: FAZ-C0.5\/3-NA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Name\u003c\/strong\u003e: Eaton FAZ branch protector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number\u003c\/strong\u003e: FAZ-C0.5\/3-NA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAN\u003c\/strong\u003e: 4015081021130\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 2.1 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 4.13 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 2.97 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL 489  CSA Std. C22.2 No. 235\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Notes\u003c\/strong\u003e: Positioned for medium inrush startup currents to provide protection for small transformers and pilot devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Branch protector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminals\u003c\/strong\u003e: Screw\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: UL 489 Industrial miniature circuit breaker - supplementary protector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 0.5 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit protection\u003c\/strong\u003e: C curve\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency rating\u003c\/strong\u003e: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt rating\u003c\/strong\u003e: 14 kAIC  10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage rating\u003c\/strong\u003e: 277\/480V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Suitable for applications where medium levels of inrush current are expected\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecondary brand\u003c\/strong\u003e: Moeller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMain function\u003c\/strong\u003e: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct series \/ family name\u003c\/strong\u003e: xEffect\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub-range name\u003c\/strong\u003e: FAZ-NA-L\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctions\u003c\/strong\u003e: Branch Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current\u003c\/strong\u003e: 0.5A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Voltage (DC)\u003c\/strong\u003e: 48Vdc (UL; single pole + neutral)\n96Vdc (UL; 2 poles in series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage (AC)\u003c\/strong\u003e: 240Vac (UL\/CSA; multi-pole)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type\u003c\/strong\u003e: Screw-clamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping curve\u003c\/strong\u003e: C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort circuit breaking rating\u003c\/strong\u003e: 10kA (UL489 \/ CSA 22.2 No. 5-02)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSize in modules (1 module = 18mm)\u003c\/strong\u003e: 3 Module(s)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting mode\u003c\/strong\u003e: DIN-rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet Height (mm)\u003c\/strong\u003e: 105 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet Width (mm)\u003c\/strong\u003e: 53.1 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual position indicator\u003c\/strong\u003e: contact position indicator red-green\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load)\u003c\/strong\u003e: 20 000 operations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU\u003c\/strong\u003e: 190643\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer product status\u003c\/strong\u003e: Commercialized\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s)\u003c\/strong\u003e: IEC60947-2\nUL489\nCSA C22.2 No. 5-02\nCE\nBGV A3\nOVE EN-6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating (Amps)\u003c\/strong\u003e: 500mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Eaton Electrical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating - AC\u003c\/strong\u003e: 480 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: FAZ-NA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating - DC\u003c\/strong\u003e: 96 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e: Bulk\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator Type\u003c\/strong\u003e: Lever\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Status\u003c\/strong\u003e: Active\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIllumination\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaker Type\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval Agency\u003c\/strong\u003e: ABS, CCC, CSA C22.2 No 235, UL489, VDE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Eaton \/ Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: FAZ-C0.5\/3-NA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 0.5A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 240VAC, 480Y\/277VAC, 96VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 240VAC, 10kA @ 480Y\/277VAC, 10kA @ 96VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: DIN Rail Systems, Industrial Control Panels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 18-6 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 6 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 18 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No. 5, IEC 60947-2, UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: ABS, CE, CSA, DNV, IEC, Lloyd's, RoHS, UL, VDE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: -25C to 75C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction Features\u003c\/strong\u003e: Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator, RoHS Compliant, Common Trip\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"EATON","offers":[{"title":"Default Title","offer_id":51150343635250,"sku":"FAZ-C0.5\/3-NA","price":467.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305978797.jpg?v=1778609886","url":"https:\/\/voomisupply.com\/products\/eaton-faz-c0-5-3-na-faz-branch-protector-0-5a","provider":"Voomi Supply","version":"1.0","type":"link"}