{"product_id":"eaton-dil-swd-32-002-manual-auto-contactor-module-for-use-with-dilmc7-dilmc32-dilm38-dila-dilmp20-contactors","title":"Eaton DIL-SWD-32-002 Manual\/Auto Contactor Module For Use With DILM(C)7\/DILM(C)32\/DILM38\/DILA\/DILMP20 Contactors","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe EATON DIL-SWD-32-002 is a manual\/auto contactor module designed to reduce panel and machine wiring complexity. It consolidates complex circuit wiring into a single cable. Connecting components over SmartWire-DT is fast and simple, streamlining testing and reducing installation, commissioning, and troubleshooting.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for use with DILM(C)7, DILM(C)32, DILM38, DILA, and DILMP20 Contactors\u003c\/li\u003e\n  \u003cli\u003e1 Contact per Module\u003c\/li\u003e\n  \u003cli\u003eBlue LED for status indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe DIL-SWD-32-002 contactor module simplifies machine wiring with SmartWire-DT, saving time and money during installation and maintenance.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: EATON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: DIL-SWD-32-002\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Manual\/Auto\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SWDT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e: 1 Contact\/Module, Front Mount, Blue LED\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuitable For Use With\u003c\/strong\u003e: DILM(C)7\/DILM(C)32\/DILM38\/DILA\/DILMP20 Contactors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC\u003c\/strong\u003e: 32101513\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number\u003c\/strong\u003e: 118561\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Code\u003c\/strong\u003e: DIL-SWD-32-002\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAN\u003c\/strong\u003e: 4015081168316\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 72 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 38 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 45 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Weight\u003c\/strong\u003e: 0.037 kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL 508  IEC\/EN 60947  UL  EN 50178  CE  CSA File No.: 2324643  CSA Class No.: 3211-07  UL File No.: E29184  IEC\/EN 61131-2  UL Category Control No.: NKCR  CSA-C22.2 No. 14-05  IEC\/EN 60947-4-1  CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Accessory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectric connection type\u003c\/strong\u003e: Spring clamp connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating mode\u003c\/strong\u003e: Address allocation via Rotary switch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl mode\u003c\/strong\u003e: Address allocation via Rotary switch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable length\u003c\/strong\u003e: \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent consumption\u003c\/strong\u003e: 40 mA, SmartWire-DT network\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput current at signal 1\u003c\/strong\u003e: 3 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of inputs (digital)\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of outputs (digital)\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current\u003c\/strong\u003e: 0.5 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e: II\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePollution degree\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct category\u003c\/strong\u003e: SmartWire-DT slave\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: Other bus systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage type\u003c\/strong\u003e: DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstant acceleration\u003c\/strong\u003e: 1 g, 8.4 - 150 Hz, according to IEC\/EN 61131-2, Vibrations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstant amplitude\u003c\/strong\u003e: 3,5 mm, 5 - 8.4 Hz, according to IEC\/EN 61131-2, Vibrations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDrop and topple\u003c\/strong\u003e: 50 mm Drop height, Drop to IEC\/EN 60068-2-31\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight of fall (IEC\/EN 60068-2-32) - max\u003c\/strong\u003e: 0.3 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting position\u003c\/strong\u003e: As DILM7 to DILM38\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock resistance\u003c\/strong\u003e: 15 g, Mechanical, according to IEC\/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient operating temperature - min\u003c\/strong\u003e: -25 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient operating temperature - max\u003c\/strong\u003e: 60 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient storage temperature - min\u003c\/strong\u003e: -30 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient storage temperature - max\u003c\/strong\u003e: 70 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental conditions\u003c\/strong\u003e: Condensation: prevent with appropriate measures\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative humidity\u003c\/strong\u003e: 5 - 95 % (non-condensing, IEC\/EN 60068-2-30)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir discharge\u003c\/strong\u003e: 8 kV, according to IEC 61131-2, level 3, ESD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurst impulse\u003c\/strong\u003e: 1 kV, SmartWire-DT cable, according to IEC\/EN 61131-2, Level 3  1 kV, Signal cable, according to IEC\/EN 61131-2, Level 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact discharge\u003c\/strong\u003e: 4 kV, according to IEC\/EN 61131-2, Level 2, ESD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic fields\u003c\/strong\u003e: 3 V\/m at 1.4 - 2 GHz (according to IEC\/EN 61131-2:2008)  10 V\/m at 80 - 1000 MHz (according to IEC\/EN 61131-2:2008)  1 V\/m at 2.0 - 2.7 GHz (according to IEC\/EN 61131-2:2008)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRadiated RFI\u003c\/strong\u003e: 10 V (IEC\/EN 61131-2:2008, Level 3)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRadio interference class\u003c\/strong\u003e: Class A (EN 55011)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal capacity\u003c\/strong\u003e: 0.2 - 1.5 mm² (24 - 16 AWG), solid  0.25 - 1.5 mm², flexible with ferrule\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated operational voltage\u003c\/strong\u003e: 15 V DC (auxiliary contact)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage at DC - min\u003c\/strong\u003e: 15 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage at DC - max\u003c\/strong\u003e: 15 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePick-up current\u003c\/strong\u003e: 125 mA (for DILM 7-9)  188 mA (for DILM 12-15)  500 mA (for DILM 17-38)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower consumption\u003c\/strong\u003e: 3 W for DILM 7-9 (Pick-up power)  4.5 W for DILM 12-15 (Sealing power)  12 W for DILM 17-38 (Pick-up power)  3 W for DILM 7-9 (Sealing power)  4.5 W for DILM 12-15 (Pick-up power)  0.5 W for DILM 17-38 (Sealing power)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing current\u003c\/strong\u003e: 188 mA, SmartWire-DT network for DILM 12-15  21 mA, SmartWire-DT network for DILM 17-38  125 mA, SmartWire-DT network for DILM 7-9\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing\u003c\/strong\u003e: Address set automatically\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection to SmartWire-DT\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type\u003c\/strong\u003e: SWD: Plug, 8-pole  Push in terminals, Auxiliary contact  External device plug SWD4-8SF2-5, SmartWire-DT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED indicator\u003c\/strong\u003e: Status indication of SmartWire-DT network: Green and orange LED\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStation\u003c\/strong\u003e: SmartWire-DT slave, SmartWire-DT network\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of auxiliary contacts\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExplosion safety category for dust\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExplosion safety category for gas\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotential isolation\u003c\/strong\u003e: Connection auxiliary contact: no\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEquipment heat dissipation, current-dependent Pvid\u003c\/strong\u003e: 0 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat dissipation capacity Pdiss\u003c\/strong\u003e: 0 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat dissipation per pole, current-dependent Pvid\u003c\/strong\u003e: 0 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated operational current for specified heat dissipation (In)\u003c\/strong\u003e: 0 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatic heat dissipation, non-current-dependent Pvs\u003c\/strong\u003e: 0.8 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.2 Corrosion resistance\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.3.1 Verification of thermal stability of enclosures\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.3.2 Verification of resistance of insulating materials to normal heat\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.3.3 Resist. of insul. mat. to abnormal heat\/fire by internal elect. effects\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.4 Resistance to ultra-violet (UV) radiation\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.5 Lifting\u003c\/strong\u003e: Does not apply, since the entire switchgear needs to be evaluated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.6 Mechanical impact\u003c\/strong\u003e: Does not apply, since the entire switchgear needs to be evaluated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.2.7 Inscriptions\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.3 Degree of protection of assemblies\u003c\/strong\u003e: Does not apply, since the entire switchgear needs to be evaluated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.4 Clearances and creepage distances\u003c\/strong\u003e: Meets the product standard's requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.5 Protection against electric shock\u003c\/strong\u003e: Does not apply, since the entire switchgear needs to be evaluated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.6 Incorporation of switching devices and components\u003c\/strong\u003e: Does not apply, since the entire switchgear needs to be evaluated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.7 Internal electrical circuits and connections\u003c\/strong\u003e: Is the panel builder's responsibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.8 Connections for external conductors\u003c\/strong\u003e: Is the panel builder's responsibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.9.2 Power-frequency electric strength\u003c\/strong\u003e: Is the panel builder's responsibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.9.3 Impulse withstand voltage\u003c\/strong\u003e: Is the panel builder's responsibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.9.4 Testing of enclosures made of insulating material\u003c\/strong\u003e: Is the panel builder's responsibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.10 Temperature rise\u003c\/strong\u003e: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.11 Short-circuit rating\u003c\/strong\u003e: Is the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.12 Electromagnetic compatibility\u003c\/strong\u003e: Is the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10.13 Mechanical function\u003c\/strong\u003e: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard \u0026amp; Approvals\u003c\/strong\u003e: ARRA Compliant, BAA Compliant, CE Certified, CSA Certified, RoHS Compliant, UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"EATON","offers":[{"title":"Default Title","offer_id":51150087881010,"sku":"DIL-SWD-32-002","price":117.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305958690.jpg?v=1778605682","url":"https:\/\/voomisupply.com\/products\/eaton-dil-swd-32-002-manual-auto-contactor-module-for-use-with-dilmc7-dilmc32-dilm38-dila-dilmp20-contactors","provider":"Voomi Supply","version":"1.0","type":"link"}