{"product_id":"eaton-chb215-ch-thermal-magnetic-circuit-breaker-15a","title":"Eaton CHB215 CH Thermal Magnetic Circuit Breaker 15A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Eaton CHB215 is a thermal magnetic circuit breaker designed for reliable circuit protection. This two-pole breaker is rated at 15A and 120\/240V, with a 10 kAIC interrupt rating. It is suitable for use with CH Loadcenters and offers thermal-magnetic protection for commercial applications, safeguarding against overloads and short circuits.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo-pole breaker with 15A amperage rating\u003c\/li\u003e\n  \u003cli\u003eOperates on 120\/240V systems\u003c\/li\u003e\n  \u003cli\u003eFeatures a 10 kAIC interrupt capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eProvides reliable thermal-magnetic protection for commercial and industrial applications. Designed for easy installation and maintenance.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: EATON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: CHB215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number\u003c\/strong\u003e: CHB215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 782113112404\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 3.75 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 3.5 IN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 1.5 IN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL 489, CSA C22.2 No. 5, Federal Specification W-P-131a, CSA, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Notes\u003c\/strong\u003e: Requires extra pole space\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Thermal magnetic circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed with\u003c\/strong\u003e: CH Loadcenters, Type PB Panelboards, Type PH Panelboards, Meter Panels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 15 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage rating\u003c\/strong\u003e: 120\/240 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit breaker type\u003c\/strong\u003e: CHB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt rating\u003c\/strong\u003e: 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire size\u003c\/strong\u003e: #14-8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of poles\u003c\/strong\u003e: Two-pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Circuit breaker, Type CHB Standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Eaton \/ Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: CHB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 15A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Type PB Panelboards, Type PH Panelboards, Meter Panels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 14-8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 14 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Padlock Attachment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No. 5, Federal Specification W-P-131a\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: CSA, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: 40C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Name\u003c\/strong\u003e: Type CHB Circuit Breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\u003c\/strong\u003e: 3.75 IN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x L)\u003c\/strong\u003e: 3.5\" x 1.5\" x 3.75\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVolts AC\u003c\/strong\u003e: 120, 240\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmps\u003c\/strong\u003e: 15\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Bolt On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating AC\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator Type\u003c\/strong\u003e: Handle\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Type\u003c\/strong\u003e: Box Lug\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 3-3\/4 x 1-1\/2 x 3-1\/2 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Bolted-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e: 60 to 75 deg C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: LI\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"EATON","offers":[{"title":"Default Title","offer_id":51150613184818,"sku":"CHB215","price":270.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305957050.jpg?v=1778614339","url":"https:\/\/voomisupply.com\/products\/eaton-chb215-ch-thermal-magnetic-circuit-breaker-15a","provider":"Voomi Supply","version":"1.0","type":"link"}