{"product_id":"cutler-hammer-ch215-2-pole-15a-240v","title":"Cutler \u0026 Hammer CH215 2-Pole 15A 240V","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe CUTLER \u0026amp; HAMMER CH215 is a 15A, two-pole miniature circuit breaker designed for residential and light commercial applications. This plug-on breaker installs into Type CH load centers and accepts #14-8 AWG wiring. Rated at 10 kAIC at 120\/240V, it features a common trip mechanism to ensure both poles open simultaneously. It is HACR rated for HVAC equipment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for residential and light commercial applications\u003c\/li\u003e\n  \u003cli\u003ePlug-on breaker installs into Type CH load centers\u003c\/li\u003e\n  \u003cli\u003eAccepts #14-8 AWG wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe Cutler-Hammer CH215 is a 15A 2-pole circuit breaker with a 10kA interrupt rating at 120\/240V, suitable for CH load centers.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CUTLER \u0026amp; HAMMER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: CH215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: CH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: CH215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 15A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Eaton CH Load Centers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: (1) 14-8 AWG (Cu\/Al), (2) 14-10 AWG (Cu\/Al)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 14 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Padlock Attachment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: UL 489, CSA C22.2, HACR\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: CSA, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: 60C to 75C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction Features\u003c\/strong\u003e: Common Trip, HACR Rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Eaton Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL Listed and CSA Certified\u003c\/strong\u003e: true\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 15 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e: 75 deg C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: Common\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120\/240 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 14 to 10 AWG, 14 to 6 AWG, 14 to 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: CH215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: CH215\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: Does Not Apply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition\u003c\/strong\u003e: Used\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CUTLER \u0026 HAMMER","offers":[{"title":"Default Title","offer_id":51203779985714,"sku":"CH215","price":30.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/307130245.jpg?v=1779705062","url":"https:\/\/voomisupply.com\/products\/cutler-hammer-ch215-2-pole-15a-240v","provider":"Voomi Supply","version":"1.0","type":"link"}