{"product_id":"cutler-hammer-bq240250-br-thermal-magnetic-circuit-breaker-40-50a","title":"Cutler \u0026 Hammer BQ240250 BR Thermal Magnetic Circuit Breaker 40\/50A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Cutler \u0026amp; Hammer BQ240250 is a 4-pole tandem thermal magnetic circuit breaker rated at 120\/240 volts and 40\/50 amps. It is designed for space-saving power distribution in residential and commercial applications requiring multiple 240V circuits. The plug-on design installs into Eaton BR, Bryant, Challenger, and Westinghouse load centers.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e4-pole tandem circuit breaker\u003c\/li\u003e\n  \u003cli\u003eRated at 120\/240 volts and 40\/50 amps\u003c\/li\u003e\n  \u003cli\u003eFor use with all type BD duplex and BQ quadplex\u003c\/li\u003e\n  \u003cli\u003eListed for HACR applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis Cutler Hammer circuit breaker delivers reliable protection and efficient power distribution in a compact design.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CUTLER \u0026amp; HAMMER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BQ240250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CUTLER \u0026amp; HAMMER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: BQ240250\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Thermal Magnetic Circuit Breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: HACR\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: BQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 40\/50A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: QUAD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 120\/240VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial Classification\u003c\/strong\u003e: Quadplex\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Eaton BR Load Centers, Bryant Load Centers, Westinghouse Load Centers, Challenger Load Centers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 14-4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 14 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Padlock Attachment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccessories\u003c\/strong\u003e: Rejection Tab\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No. 5, Federal Specification W-C375, UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: CSA, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: 60C to 75C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction Features\u003c\/strong\u003e: HACR Rated, Independent Trip, Rejection Tab\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 1.4 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 3.1 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 3.2 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliances\u003c\/strong\u003e: Federal Specifications Classification W-C375\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Thermal magnetic circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed with\u003c\/strong\u003e: Type BR Loadcenters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: (1) Two-Pole 40A, (1) Two-Pole 50A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage rating\u003c\/strong\u003e: 120\/240 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: T194\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit breaker type\u003c\/strong\u003e: BQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: Plug-on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt rating\u003c\/strong\u003e: 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMain circuit breaker\u003c\/strong\u003e: BQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire size\u003c\/strong\u003e: #14-4 AWG Cu\/Al\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of poles\u003c\/strong\u003e: Four-pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial features\u003c\/strong\u003e: Includes rejection tab feature\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame Type\u003c\/strong\u003e: BQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 40 AMPERE (OUTSIDE POLE), 50 AMPERE (CENTER POLE, INDEPENDENT TRIP POLE)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 14 TO 4 AWG (ALUMINUM\/COPPER)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e: 10 KILOAMPERE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: For Heating, Air Conditioning, and Refrigeration (HACR)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo. Of Poles\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size Range\u003c\/strong\u003e: 14 to 4AWG Cu\/Al\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: 60 to 75 Deg C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: Meet UL 489, CSA, NEMA standards, Federal Spec Classification W-C 375 b\/GEN.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVolts\u003c\/strong\u003e: 240\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmps\u003c\/strong\u003e: 50\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CUTLER \u0026 HAMMER","offers":[{"title":"Default Title","offer_id":51202925265202,"sku":"BQ240250","price":127.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/307130314.jpg?v=1779701976","url":"https:\/\/voomisupply.com\/products\/cutler-hammer-bq240250-br-thermal-magnetic-circuit-breaker-40-50a","provider":"Voomi Supply","version":"1.0","type":"link"}