{"product_id":"cutler-hammer-bab2070-thermal-magnetic-circuit-breaker-70-a","title":"Cutler \u0026 Hammer BAB2070 Thermal Magnetic Circuit Breaker 70 A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe CUTLER \u0026amp; HAMMER BAB2070 is a thermal magnetic circuit breaker. This Quicklag industrial thermal-magnetic circuit breaker features bolt-on mounting and is rated for 70 A. It is suitable for use in commercial to light industrial applications, providing overcurrent safety. HACR rated for air conditioning, heating, and refrigeration applications.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBolt-on mounting\u003c\/li\u003e\n  \u003cli\u003eHACR rated\u003c\/li\u003e\n  \u003cli\u003e10 kAIC interrupt rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe BAB2070 circuit breaker ensures a direct power feed and energy efficiency, and is a reliable choice for various applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CUTLER \u0026amp; HAMMER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BAB2070\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Name\u003c\/strong\u003e: Eaton BAB thermal magnetic circuit breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Number\u003c\/strong\u003e: BAB2070\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 786679302705\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth\u003c\/strong\u003e: 3.6 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 3.7 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 2.2 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Notes\u003c\/strong\u003e: HACR rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Thermal magnetic circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit breaker type\u003c\/strong\u003e: BAB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Method\u003c\/strong\u003e: Bolt-on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of poles\u003c\/strong\u003e: Two-pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Quicklag industrial thermal-magnetic circuit breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 70 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt rating\u003c\/strong\u003e: 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: Non-Interchangeable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage rating\u003c\/strong\u003e: 120\/240 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial features\u003c\/strong\u003e: Bolt-on mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Eaton Cutler-Hammer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem model number\u003c\/strong\u003e: CHBAB2070\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120\/240VAC, 24VDC, 48VDC, 62.5VDC, 80VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWattage\u003c\/strong\u003e: 8400 watts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem Package Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Bolt-On Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwitch Style\u003c\/strong\u003e: Electromechanical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncluded Components\u003c\/strong\u003e: CHBAB2070\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBatteries Included?\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBatteries Required?\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 70 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: Generation - Conventional Energy - Conventional EnergyGeneration - Renewable Energy - Alternative EnergyOtherMarine Vessels and Equipment - Marine Vessels and Equipment - OtherDatacenters - IT Space: CI and Hyper ConvergedResidential Bldgs \u0026amp; Facilities - Residential Bldgs \u0026amp; Facilities - Other\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 2 Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip\u003c\/strong\u003e: Fixed Trip\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL, CSA. CE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Bolt-on\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Commercial\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 8 To 1\/0 AWG (Aluminum\/Copper, Load)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal\u003c\/strong\u003e: Extended Tang Line Terminal, Box Lug Load Terminal Terminal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: BAB BA, QBHW\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Quicklag[R]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 120\/240VAC, 5kA @ 24VDC, 5kA @ 48VDC, 5kA @ 62.5VDC, 5kA @ 80VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 8-1\/0 AWG (Al\/Cu)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 1\/0 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccessories\u003c\/strong\u003e: Extended Tang Line Terminal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: HACR, UL 489, CSA C22.2 No. 5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: 40C\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CUTLER \u0026 HAMMER","offers":[{"title":"Default Title","offer_id":51207351206194,"sku":"BAB2070","price":130.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/307130230.jpg?v=1779727653","url":"https:\/\/voomisupply.com\/products\/cutler-hammer-bab2070-thermal-magnetic-circuit-breaker-70-a","provider":"Voomi Supply","version":"1.0","type":"link"}