{"product_id":"cooper-bussmann-bp-frn-r-30id-30a-250v-class-rk5-indicating-fuse","title":"Cooper Bussmann BP\/FRN-R-30ID 30A 250V Class RK5 Indicating Fuse","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe COOPER BUSSMANN BP\/FRN-R-30ID is a 30-amp, 250-volt indicating fuse rated for Class RK5 service. It uses a dual-element, time-delay design that tolerates motor inrush current while still providing current-limiting protection against sustained overloads and short circuits. A key field feature is the indicating label: if the fuse opens, the label darkens, giving technicians a fast visual confirmation of fuse status without removing the fuse or using a meter. This pack contains two fuses and is suitable for use by licensed electricians and qualified maintenance personnel working on commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp\u003eThese fuses are suited for AC power distribution applications including service mains, feeders, and branch circuits. The dual-element time-delay characteristic makes them appropriate for motor branch circuits where inrush current would nuisance-trip a standard fuse. They also serve transformer and other inductive load circuits, as well as lighting and heating loads. The carded two-pack format is intended for service and replacement work where a spare on hand is standard practice.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eIndicating label darkens visually when fuse has opened — no meter required for quick status check\u003c\/li\u003e\n  \u003cli\u003eDual-element, time-delay construction tolerates motor inrush without sacrificing short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCurrent-limiting Class RK5 rating provides downstream component protection during fault events\u003c\/li\u003e\n  \u003cli\u003eRated 30 amps at 250 volts for AC power distribution service\u003c\/li\u003e\n  \u003cli\u003eUL Listed\u003c\/li\u003e\n  \u003cli\u003eSold as a two-pack on a card for convenient replacement inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use in AC power distribution system mains, feeders, branch circuits, motor branch circuits, transformer and inductive load circuits, and lighting and heating non-inductive load circuits requiring a Class RK5 time-delay fuse rated 30A at 250V.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation and replacement of current-limiting fuses must be performed by a licensed electrician in accordance with the National Electrical Code (NEC) and all applicable local codes. De-energize and lock out the circuit at the disconnect or panel before handling any fuse or fuseholder. Verify the replacement fuse ampere rating, voltage rating, and class match the fuseholder and circuit requirements before installing. Never substitute a higher-ampere or different-class fuse to restore service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmpere Rating\u003c\/strong\u003e: 30A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 250V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Class\u003c\/strong\u003e: RK5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Type\u003c\/strong\u003e: Dual Element, Time Delay, Current Limiting, Indicating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Quantity\u003c\/strong\u003e: 2 fuses per pack\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 2.375 inches L x 1.375 inches W x 0.25 inches H\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.3 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e: Carded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: COOPER BUSSMANN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BP\/FRN-R-30ID\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BUSSMANN","offers":[{"title":"Default Title","offer_id":51558973210930,"sku":"BP\/FRN-R-30ID","price":124.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/def2ec649070146e4c3d6c6c3eaaebf0.jpg?v=1786424505","url":"https:\/\/voomisupply.com\/products\/cooper-bussmann-bp-frn-r-30id-30a-250v-class-rk5-indicating-fuse","provider":"Voomi Supply","version":"1.0","type":"link"}