{"product_id":"carrier-bs2aan000299-80-afue-299000-btu-h-gas-fired-steam-boiler-299000-btu-h","title":"Carrier BS2AAN000299 80% AFUE 299000 Btu\/h Gas-Fired Steam Boiler (299000 Btu\/h)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eCarrier BS2AAN000299 is a cast-iron gas-fired steam boiler with a maximum input of 299,000 Btu\/h and 80% AFUE. The compact, factory-packaged unit includes factory-installed wiring and controls (except room thermostat), thermal-pin cast-iron sections with steel push nipples, titanium composite burners, and an integral draft system. Sections are hydrostatically tested and the casing is insulated with fiberglass for improved operating efficiency. It is CSA certified for natural gas and field convertible to propane with a factory kit.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMaximum input 299,000 Btu\/h; 80% AFUE; thermal-pin cast-iron sections with steel push nipples.\u003c\/li\u003e\n  \u003cli\u003eTitanium composite burners, integral draft system, and electronic combustion\/ignition; operates on 110â125 V, 60 Hz.\u003c\/li\u003e\n  \u003cli\u003eFactory-supplied safety controls including automatic gas valve and intermittent pilot; CSA certified for natural gas; compatible with Category 1 venting and automatic vent damper.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003e299,000 Btu\/h gas-fired steam boiler with cast-iron sections, titanium burners, factory-installed controls, CSA certification, and propane convertibility.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CARRIER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BS2AAN000299\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Carrier\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: BS2AAN000299\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Gas-fired steam boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: BS2 (Comfort)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 80%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Input (Btu\/h)\u003c\/strong\u003e: 299,000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel\u003c\/strong\u003e: Natural gas (field convertible to propane with factory kit)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 110-125 V, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombustion \/ Ignition\u003c\/strong\u003e: Natural draft; electronic combustion\/ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Material\u003c\/strong\u003e: Thermal-pin cast-iron sections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Titanium composite burners\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSection Seal\u003c\/strong\u003e: Steel push nipples\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDraft\u003c\/strong\u003e: Integral draft system (no external draft diverter required)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCasing\u003c\/strong\u003e: Insulated fiberglass casing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Controls\u003c\/strong\u003e: Automatic gas valve and intermittent pilot; protection against overheating, pressure build-up, and low-water operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CSA certified for natural gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Venting\u003c\/strong\u003e: Category 1 venting; compatible with factory-supplied automatic vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure (Water)\u003c\/strong\u003e: 50 psig\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure (Steam)\u003c\/strong\u003e: 15 psig\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSection Hydrostatic Test\u003c\/strong\u003e: Sections hydrostatically tested at factory; individual sections to 125 psig; assembled sections tested to 75 psig\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (H x D x W)\u003c\/strong\u003e: 36.375 in x 26.5 in x 30.75 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Connection Size\u003c\/strong\u003e: 1\/2 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Connection Type\u003c\/strong\u003e: NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting \/ Installation\u003c\/strong\u003e: Floor standing; suitable for installation on combustible floors with optional combustible floor base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CARRIER","offers":[{"title":"Default Title","offer_id":51620971807026,"sku":"BS2AAN000299","price":3019.01,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/6506775316d1ac8789655ee49e4f0316_7753c51a-84f7-4a48-a92a-5eb86a9b68f3.png?v=1787348176","url":"https:\/\/voomisupply.com\/products\/carrier-bs2aan000299-80-afue-299000-btu-h-gas-fired-steam-boiler-299000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}