{"product_id":"carlin-combustion-technology-48245s-control-4x4-45-sec","title":"Carlin Combustion Technology 48245S Control 4X4 45-Sec","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe CARLIN COMBUSTION TECHNOLOGY 48245S is a burner primary control designed for constant\/intermittent duty. It is used on EZ1\/EZ2\/EZ3\/EZ66\/99FRD\/100CRD\/102CRD oil burners and features a 45-second trial for ignition and smart ignition. This control serves as a direct replacement for 3-wire primary controls and incorporates Safety Monitoring Circuit (SMC) Technology.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePrimary Control\u003c\/li\u003e\n  \u003cli\u003eConstant\/Intermittent Duty\u003c\/li\u003e\n  \u003cli\u003eUsed On EZ1\/EZ2\/EZ3\/EZ66\/99FRD\/100CRD\/102CRD Oil Burner\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eFeatures a 45-second trial for ignition and smart ignition. Compatible with thermostat\/aquastat.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CARLIN COMBUSTION TECHNOLOGY\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 48245S\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem\u003c\/strong\u003e: Primary Control, Constant\/Intermittent Duty\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdditional Information\u003c\/strong\u003e: Trial for Ignition 45 Second; Includes Smart Ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCATALOG NUMBER\u003c\/strong\u003e: 48245S\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: HVAC\/R \u0026amp; Fans\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e: Burner Primary Control; Item Primary Control, Constant\/Intermittent Duty; Used On EZ1\/EZ2\/EZ3\/EZ66\/99FRD\/100CRD\/102CRD Oil Burner; Trial for Ignition 45 Second; Includes Smart Ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Name\u003c\/strong\u003e: Carlin Combustion Technology\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 48245S\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC Code\u003c\/strong\u003e: 40101800\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed On\u003c\/strong\u003e: EZ1\/EZ2\/EZ3\/EZ66\/99FRD\/100CRD\/102CRD Oil Burner\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrial for Ignition\u003c\/strong\u003e: 45 Second\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncludes\u003c\/strong\u003e: Smart Ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Oil Control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTFI (secs)\u003c\/strong\u003e: Selectable 45 or 15\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre purge\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePost purge\u003c\/strong\u003e: N\/A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRecycles\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Intermittent Smart Ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Input (From Limit Circuit)\u003c\/strong\u003e: 120 vac, 60 Hz, 10 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Load\u003c\/strong\u003e: 10 FLA, 60 LRA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnitor Load\u003c\/strong\u003e: 120 vac, 60 Hz, 500 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Limits\u003c\/strong\u003e: +32ºF to +140ºF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e: -40ºF to +185ºF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermostat Anticipator Current\u003c\/strong\u003e: 0.1 A, AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgencies\u003c\/strong\u003e: UL \u0026amp; ULC Recognized Component United States \u0026amp; Canada\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (From Limit Circuit)\u003c\/strong\u003e: 120 vac, 60 Hz, 10 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CARLIN\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CARLIN COMBUSTION TECHNOLOGY","offers":[{"title":"Default Title","offer_id":50971637907762,"sku":"48245S","price":95.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/296439737.jpg?v=1773381042","url":"https:\/\/voomisupply.com\/products\/carlin-combustion-technology-48245s-control-4x4-45-sec","provider":"Voomi Supply","version":"1.0","type":"link"}