{"product_id":"cambridge-lee-industries-061212200b-line-set-20-ft","title":"Cambridge-lee Industries 061212200B Line Set 20 Ft","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe CAMBRIDGE-LEE INDUSTRIES 061212200B is a pre-insulated copper refrigerant line set designed for connecting outdoor condensing units to indoor air handlers in split-type refrigeration and air conditioning systems. The set includes a 3\/8 inch liquid line and a 3\/4 inch suction line, both with plain end connections, running a total length of 20 feet. The suction line is wrapped in 3\/4 inch black polyethylene hard shell insulation rated for UV exposure and approved for use with R-410A refrigerant. Both lines are manufactured from copper to ASTM B743\/B88 material standards. Licensed HVAC technicians install this line set as part of new system installations or replacement work on split system equipment.\u003c\/p\u003e\n\u003cp\u003eThis line set is suited for use in ductless mini-split systems, variable refrigerant flow commercial systems, and traditional split system air conditioners and heat pumps. The 20-foot run length fits a wide range of standard residential and light commercial installation distances between the outdoor unit and indoor evaporator. The insulation is marked every foot to assist with accurate measurement and routing during installation. The rugged, anti-tear exterior simplifies pulling the line set through walls, chases, and conduit without damaging the insulation jacket.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e3\/8 inch liquid line and 3\/4 inch suction line in a single pre-paired assembly\u003c\/li\u003e\n  \u003cli\u003e3\/4 inch black polyethylene hard shell insulation rated for UV resistance\u003c\/li\u003e\n  \u003cli\u003eR-410A approved insulation for compatibility with current refrigerant systems\u003c\/li\u003e\n  \u003cli\u003eAnti-tear exterior reduces insulation damage during installation pulls\u003c\/li\u003e\n  \u003cli\u003eInsulation marked every foot for easy field measurement\u003c\/li\u003e\n  \u003cli\u003ePlain end x plain end connections for field brazing or flaring to fit system requirements\u003c\/li\u003e\n  \u003cli\u003eMeets ASTM E84\/C1427 and UL applicable standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with ductless mini-split systems, VRF commercial systems, and split system air conditioners and heat pumps. Suitable for R-410A refrigerant applications.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed HVAC technician holding an EPA Section 608 refrigerant handling certification. Disconnect and lock out all electrical power to both the indoor and outdoor units before beginning line set connections. Plain end connections require field brazing or mechanical flaring; follow applicable local mechanical codes and manufacturer specifications for joint type and leak testing procedures. Ensure the line set is properly supported and protected against physical damage after installation to maintain insulation integrity.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Line Diameter\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction Line Diameter\u003c\/strong\u003e: 3\/4 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 20 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Thickness\u003c\/strong\u003e: 3\/4 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Material\u003c\/strong\u003e: Black Polyethylene Hard Shell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Material\u003c\/strong\u003e: Copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnd Connection\u003c\/strong\u003e: Plain End x Plain End\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant Compatibility\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Standard\u003c\/strong\u003e: ASTM B743\/B88\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplicable Standards\u003c\/strong\u003e: ASTM E84\/C1427, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Ductless Mini-Split System, VRF Commercial System, Split System Air Conditioner and Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CAMBRIDGE-LEE INDUSTRIES\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 061212200B\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CAMBRIDGE-LEE INDUSTRIES","offers":[{"title":"Default Title","offer_id":51284041662770,"sku":"061212200B","price":187.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309278369.jpg?v=1781066969","url":"https:\/\/voomisupply.com\/products\/cambridge-lee-industries-061212200b-line-set-20-ft","provider":"Voomi Supply","version":"1.0","type":"link"}