{"product_id":"cambridge-lee-industries-061008500b-line-set-50-ft","title":"Cambridge-lee Industries 061008500B Line Set 50 Ft","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe CAMBRIDGE-LEE INDUSTRIES 061008500B is a pre-insulated copper line set designed for connecting the indoor and outdoor units of split-system and ductless mini-split HVAC systems. It ships in a 50-foot length with a 3\/8-inch liquid line and a 5\/8-inch suction line, both terminated with plain ends for field flaring or brazing. The suction line is wrapped in 1\/2-inch black polyethylene hard-shell insulation rated for UV exposure and approved for use with R-410A refrigerant. Insulation is marked every foot for quick measurement during rough-in. Licensed HVAC technicians handle the installation of this component in residential and light commercial applications.\u003c\/p\u003e\n\u003cp\u003eThis line set is suitable for ductless mini-split systems, VRF commercial systems, and conventional split-system air conditioners and heat pumps. The rugged, anti-tear exterior reduces the risk of insulation damage during the pull-through process in wall chases, conduit, or tight building cavities. Plain-end terminations allow the installer to cut to the required length and prepare connections on site using standard flaring or brazing methods. The material meets ASTM B743 and B88 specifications for ACR copper tubing.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e50-foot length accommodates standard residential and light commercial line runs\u003c\/li\u003e\n  \u003cli\u003e3\/8-inch liquid line and 5\/8-inch suction line in a single pre-insulated assembly\u003c\/li\u003e\n  \u003cli\u003e1\/2-inch black polyethylene hard-shell insulation rated for UV resistance\u003c\/li\u003e\n  \u003cli\u003eR-410A approved insulation suitable for current-generation refrigerant systems\u003c\/li\u003e\n  \u003cli\u003eRugged anti-tear exterior designed for easier pulling through conduit or wall cavities\u003c\/li\u003e\n  \u003cli\u003eInsulation marked every foot for accurate field measurement and cutting\u003c\/li\u003e\n  \u003cli\u003ePlain end x plain end termination for field flaring or brazing to system connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with ductless mini-split systems, VRF commercial systems, and split-system air conditioners and heat pumps using R-410A refrigerant. Plain-end terminations are compatible with standard ACR flaring and brazing procedures.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed HVAC technician holding an EPA Section 608 refrigerant handling certification. Confirm the system is recovered and de-pressurized before cutting or connecting any refrigerant lines. Plain ends require proper field flaring or brazing per the equipment manufacturer's instructions and applicable mechanical codes. Insulation joints and cut ends should be sealed with compatible foam tape or insulation wrap to prevent condensation and UV degradation after installation.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Line Diameter\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction Line Diameter\u003c\/strong\u003e: 5\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 50 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Thickness\u003c\/strong\u003e: 1\/2 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Material\u003c\/strong\u003e: Black Polyethylene Hard Shell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTubing Material\u003c\/strong\u003e: Copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnd Connection\u003c\/strong\u003e: Plain End x Plain End\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant Compatibility\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUV Resistance\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Specification\u003c\/strong\u003e: ASTM B743\/B88\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplicable Standard\u003c\/strong\u003e: ASTM E84\/C1427, UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Ductless Mini-Split System, VRF Commercial System, Split System Air Conditioner and Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: CAMBRIDGE-LEE INDUSTRIES\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 061008500B\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CAMBRIDGE-LEE INDUSTRIES","offers":[{"title":"Default Title","offer_id":51284073283890,"sku":"061008500B","price":325.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309278386.jpg?v=1781067854","url":"https:\/\/voomisupply.com\/products\/cambridge-lee-industries-061008500b-line-set-50-ft","provider":"Voomi Supply","version":"1.0","type":"link"}