{"product_id":"bryant-288bnv048000-heat-pump-18-seer-4-0-tons","title":"Bryant 288bnv048000 Heat Pump 18 Seer 4.0 Tons","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe BRYANT 288bnv048000 is a variable-capacity heat pump designed for residential split-system applications. It uses inverter-driven technology with a rotary compressor to deliver variable-stage operation, stepping down to 25% capacity to match current load conditions. Nominal cooling capacity is 44,000 BTU\/h with a rated SEER of 18 and a nominal HSPF of 8.2. The brushless DC condenser fan motor and TXV metering on the cooling side combine to support efficient operation across a broad range of ambient conditions. Licensed HVAC technicians handle installation and commissioning of this outdoor unit.\u003c\/p\u003e\u003cp\u003eThis unit is sized for 4-ton nominal residential cooling and heating applications. It operates as a single-phase system at standard residential voltage. The minimum heating ambient temperature rating of 35 to 39 degrees F makes it suitable for climates that see moderate winter lows. Enhanced dehumidification capability during cooling mode makes it a practical choice for humid climates where humidity control is a priority alongside sensible cooling.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVariable-stage rotary compressor with inverter control — operates down to 25% capacity for low-load efficiency\u003c\/li\u003e\n\u003cli\u003e18 SEER rated efficiency with a nominal HSPF of 8.2\u003c\/li\u003e\n\u003cli\u003eTXV metering on cooling side and EXV metering on heating side for precise refrigerant control\u003c\/li\u003e\n\u003cli\u003eBrushless DC condenser fan motor with variable-speed operation for reduced sound levels\u003c\/li\u003e\n\u003cli\u003eMaximum sound level of 73 decibels at rated conditions\u003c\/li\u003e\n\u003cli\u003eLouver-style coil guard protects the outdoor coil on all sides\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style variable-capacity outdoor heat pump unit for use with compatible Bryant or carrier-platform indoor air handlers and furnace coil systems in residential split-system configurations.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician holding an EPA Section 608 certification for refrigerant handling. Shut off all electrical power at the disconnect and breaker before making any connections. Line connections use sweat fittings on both the liquid and suction lines; follow standard nitrogen-purge and leak-test procedures before evacuation and charge. Consult local mechanical codes and the manufacturer installation instructions for clearance, pad, and electrical disconnect requirements.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Tonnage\u003c\/strong\u003e: 4.0 tons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 44,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cooling Capacity\u003c\/strong\u003e: 46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Cooling Capacity\u003c\/strong\u003e: 44,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Heating Capacity\u003c\/strong\u003e: 50,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Heating Capacity\u003c\/strong\u003e: 31,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER\u003c\/strong\u003e: 18\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal EER\u003c\/strong\u003e: 9.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal HSPF\u003c\/strong\u003e: 8.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal COP\u003c\/strong\u003e: 3.22\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum COP\u003c\/strong\u003e: 3.58\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type\u003c\/strong\u003e: Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Stage\u003c\/strong\u003e: Variable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Single\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Voltage\u003c\/strong\u003e: 197 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e: 253 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor RLA\u003c\/strong\u003e: 23.9 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e: 31.4 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor FLA\u003c\/strong\u003e: 1.32 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Fan Motor Type\u003c\/strong\u003e: Brushless DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Fan Motor HP\u003c\/strong\u003e: 1\/3 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Fan Motor Speed\u003c\/strong\u003e: Variable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Diameter\u003c\/strong\u003e: 20 to 24 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal CFM\u003c\/strong\u003e: 4,500 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetering Device (Cooling)\u003c\/strong\u003e: TXV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetering Device (Heating)\u003c\/strong\u003e: EXV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Line Size\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Line Fitting\u003c\/strong\u003e: Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Line Size\u003c\/strong\u003e: 1-1\/8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Line Fitting\u003c\/strong\u003e: Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Heating Ambient Temperature\u003c\/strong\u003e: 35 to 39 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Sound Level\u003c\/strong\u003e: 73 decibels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Guard Type\u003c\/strong\u003e: Louver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fins Per Inch\u003c\/strong\u003e: 20 FPI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 33.38 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 33.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 43.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 237 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: BRYANT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 288bnv048000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CARRIER","offers":[{"title":"Default Title","offer_id":51138749432114,"sku":"288BNV048000","price":3427.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533117.png?v=1778781529","url":"https:\/\/voomisupply.com\/products\/bryant-288bnv048000-heat-pump-18-seer-4-0-tons","provider":"Voomi Supply","version":"1.0","type":"link"}