{"product_id":"bryant-280anv024000-variable-speed-heat-pump-2-ton-20-seer","title":"Bryant 280anv024000 Variable Speed Heat Pump 2 Ton 20 Seer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe BRYANT 280anv024000 is a 2-ton variable-speed outdoor heat pump designed for split-system residential HVAC installations. Rated at up to 20.5 SEER and a maximum COP of 4.7, it delivers both cooling and heating through a communicating inverter-driven scroll compressor. The unit operates on single-phase 208\/230-volt power and uses R-410A refrigerant. An ECM condenser fan motor with variable-speed control reduces energy draw during part-load conditions. TXV metering handles the cooling cycle and an EXV manages the heating cycle. Sound-blanket construction keeps max sound output at 71 decibels. Licensed HVAC technicians perform installation and commissioning.\u003c\/p\u003e\u003cp\u003eThis heat pump suits residential split-system installations where high-efficiency, variable-speed performance is required. Its communicating control interface allows integration with compatible Bryant system controls and thermostats. The unit is configured for vertical mounting and accepts sweat connections on both the 3\/8-inch liquid line and the 7\/8-inch suction line. Nominal airflow is rated at 2,700 CFM. Heating performance extends down to a minimum ambient temperature of 0 to 29 degrees F, making it suitable for cold-climate residential applications. Louver-style coil guards protect the outdoor coil fins, which are spaced at 20 fins per inch.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eVariable-speed inverter-driven scroll compressor for part-load efficiency\u003c\/li\u003e\n\u003cli\u003eUp to 20.5 SEER cooling efficiency rating\u003c\/li\u003e\n\u003cli\u003eMaximum COP of 4.7 for heating performance\u003c\/li\u003e\n\u003cli\u003eECM condenser fan motor rated at 1\/3 HP and 256 RPM nominal\u003c\/li\u003e\n\u003cli\u003eCommunicating system control capability for integrated Bryant system operation\u003c\/li\u003e\n\u003cli\u003eSound blanket included; maximum sound level 71 decibels\u003c\/li\u003e\n\u003cli\u003eTXV cooling metering device and EXV heating metering device\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use in communicating split-system heat pump configurations requiring a 2-ton, R-410A outdoor unit with variable-speed operation and 208\/230-volt single-phase power supply.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation instructions. Disconnect and lock out all electrical power before servicing. Refrigerant handling requires EPA Section 608 certification. Liquid and suction line connections are sweat-type; follow accepted brazing practices and leak-test the system before charging. Verify that the indoor air handler and thermostat are compatible with the communicating control interface before startup.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 24,000 BTU\/h (2 Tons)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cooling Capacity\u003c\/strong\u003e: 25,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Heating Capacity\u003c\/strong\u003e: 23,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Heating Capacity\u003c\/strong\u003e: 23,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum SEER\u003c\/strong\u003e: 20.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum SEER\u003c\/strong\u003e: 18.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum COP\u003c\/strong\u003e: 4.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal CFM\u003c\/strong\u003e: 2,700 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 208\/230 volts, Single Phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity (MCA)\u003c\/strong\u003e: 23.5 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Circuit Breaker\u003c\/strong\u003e: 30 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor RLA\u003c\/strong\u003e: 16.5 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLRA\u003c\/strong\u003e: 20-24 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor FLA\u003c\/strong\u003e: 2.8 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Motor Type\u003c\/strong\u003e: ECM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Motor HP\u003c\/strong\u003e: 1\/3 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser Motor Nominal RPM\u003c\/strong\u003e: 256 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Diameter\u003c\/strong\u003e: 26 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type\u003c\/strong\u003e: Scroll, Inverter-Driven\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetering Device (Cooling)\u003c\/strong\u003e: TXV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetering Device (Heating)\u003c\/strong\u003e: EXV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Line Size\u003c\/strong\u003e: 3\/8 inches (Sweat)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Line Size\u003c\/strong\u003e: 7\/8 inches (Sweat)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Heating Ambient Temperature\u003c\/strong\u003e: 0-29 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Sound Level\u003c\/strong\u003e: 71 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Guard Type\u003c\/strong\u003e: Louver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fins Per Inch\u003c\/strong\u003e: 20 FPI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Pressure Switch\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccumulator\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound Blanket\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Length\u003c\/strong\u003e: 37.00 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 37.12 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 50.00 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 365.5 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: BRYANT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 280anv024000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CARRIER","offers":[{"title":"Default Title","offer_id":51138384560434,"sku":"280ANV024000","price":3341.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533119.png?v=1778781299","url":"https:\/\/voomisupply.com\/products\/bryant-280anv024000-variable-speed-heat-pump-2-ton-20-seer","provider":"Voomi Supply","version":"1.0","type":"link"}