{"product_id":"belimo-22dtm-51-duct-co2-humidity-and-temp-sensor","title":"Belimo 22DTM-51 Duct CO2, Humidity And Temp. Sensor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe BELIMO 22DTM-51 is an active sensor for measuring CO2, temperature, and humidity in ducts. It features dual channel CO2 technology and provides 0 to 5 VDC, 0 to 10 VDC active output signals. The sensor comes in a NEMA 4X enclosure and includes a CO2 gas conduit adaptor.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eActive sensor for measuring CO2, temperature, and humidity\u003c\/li\u003e\n  \u003cli\u003eDual Channel CO2 Technology\u003c\/li\u003e\n  \u003cli\u003eCO2 Gas, Conduit Adaptor, Field Selectable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis duct sensor is ideal for monitoring air quality in various applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: BELIMO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 22DTM-51\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Duct Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 4X\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Lead\u003c\/strong\u003e: 5-7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: 7 Inch Probe\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensors Application\u003c\/strong\u003e: Gas Specialty, Humidity, Temperature\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage Signal Range\u003c\/strong\u003e: 0 To 5 V, 0 To 10 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem Number\u003c\/strong\u003e: 22DTM-51\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Belimo\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Configuration\u003c\/strong\u003e: Duct\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor\u003c\/strong\u003e: CO2 Carbon Dioxide\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Type\u003c\/strong\u003e: CO2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage AC\/DC\u003c\/strong\u003e: AC\/DC 24 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e: Terminals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasured Values\u003c\/strong\u003e: CO2, Temperature, Humidity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 0...5 V, 0...10 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring Range CO2\u003c\/strong\u003e: Default setting: 0...2000 ppm\nWith A-22G-A05: 0...5000 ppm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring Range Humidity\u003c\/strong\u003e: 0...100% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring Range Temperature\u003c\/strong\u003e: 40...140°F [4...60°C]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage [Range]\u003c\/strong\u003e: 3 x 0...5 V, 0...10 V, min. resistance 10 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput signal active note\u003c\/strong\u003e: output 0...5\/10 V with jumper adjustable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Length\u003c\/strong\u003e: 7\" [180 mm]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: 22DTM-51\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition\u003c\/strong\u003e: New\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0 - 2,000 ppm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Greenhouse,Laboratory,Food \u0026amp; Beverage,IAQ,Parking Garage,Agricultural\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e: 24 VAC, ±10%, 2.9 VA  (15...24 VDC, ±10%,\n    1.5 W)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range (CO2)\u003c\/strong\u003e: 0 to 2000 ppm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range (Humidity)\u003c\/strong\u003e: 0 to 100% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature\u003c\/strong\u003e: 32°F to 120°F [0°C to 50°C]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy (CO2)\u003c\/strong\u003e: ±75 ppm; \u0026gt;750 ppm: ±10% of measuring value\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy (Humidity)\u003c\/strong\u003e: ±2% between 10 to 90% RH @ 70°F [21°C]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy (Temperature)\u003c\/strong\u003e: ±1% of measuring range @ 70°F [21°C]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 85% RH non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 32°F to  120°F [0°C to 50°C]\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Output\u003c\/strong\u003e: DC 0-5V, DC 0-10V,  4-20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Technology\u003c\/strong\u003e: NDIR (non-dispersive  infrared) with\n    stainless steel wire mesh filter, dual channel calibration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.26 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: IEC\/EN, ISO 9001, UL 2043, UL 50\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 5 years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Gas Detection Duct\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Sheet\u003c\/strong\u003e: https:\/\/www.belimo.com\/mam\/general-documents\/datasheets\/en-us\/belimo_22DTM-51.._datasheet_en-us.pdf (Download)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e: https:\/\/www.belimo.com\/mam\/global\/technical-documentation\/installation_instructions\/belimo_22DC-.._22DTC-.._22DTM-.._22DCV-.._22DCM-.._22DCK-.._installation-instructions.pdf (Download)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay name 2\u003c\/strong\u003e: Installation Instructions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIn_stock\u003c\/strong\u003e: true\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMargin\u003c\/strong\u003e: 30\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eP21 delete flag\u003c\/strong\u003e: false\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct category\u003c\/strong\u003e: Gas \u0026amp; Specialty Sensors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct subcategory\u003c\/strong\u003e: Gas Detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestricted class id\u003c\/strong\u003e: NULL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestricted item\u003c\/strong\u003e: false\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: Belimo\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort desc\u003c\/strong\u003e: Duct Sensor CO2 \/ Humidity \/ Temperature, Air, 24 V AC\/DC, 7 Inch Probe, Terminals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSku\u003c\/strong\u003e: BEL-22DTM51\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrategic_value\u003c\/strong\u003e: 47\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupplier part number\u003c\/strong\u003e: 22DTM-51\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Air Quality Duct Sensor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra store sync us\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVendor enabled\u003c\/strong\u003e: Y\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eYorkland id\u003c\/strong\u003e: 22DTM-51\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"BELIMO","offers":[{"title":"Default Title","offer_id":51161805979954,"sku":"22DTM-51","price":714.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/306249442.jpg?v=1778882422","url":"https:\/\/voomisupply.com\/products\/belimo-22dtm-51-duct-co2-humidity-and-temp-sensor","provider":"Voomi Supply","version":"1.0","type":"link"}