{"product_id":"bapi-ba-10k-2-h300-d-bb2-duct-humidity-transmitter","title":"Bapi BA\/10K-2-H300-D-BB2 Duct Humidity Transmitter","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe BAPI BA\/10K-2-H300-D-BB2 is a combination humidity and temperature transmitter designed for duct-mount installation in commercial and industrial HVAC systems. It uses a 10K Type 2 thermistor for temperature sensing and delivers humidity readings at 3 percent accuracy. The output is field-selectable between 0 to 5 VDC and 4 to 20 mA, allowing integration with a wide range of building automation and control systems. Power requirements are 24 VAC or 24 VDC. The unit is housed in a BAPI Box 2 polycarbonate enclosure rated NEMA 4 and IP66 for reliable performance in demanding environments. Licensed HVAC controls technicians and building automation specialists are the typical installers.\u003c\/p\u003e\n\u003cp\u003eThis transmitter is suited for duct applications across a broad range of facilities and system functions including humidification, dehumidification, supply air, discharge air, return air, and economizer control. It is also specified for clean rooms, data centers, process control environments, schools, hospitals, and office buildings where accurate humidity and temperature monitoring in the airstream is required. The duct-mount configuration places the sensing element directly in the airflow for responsive, representative readings.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e3 percent humidity accuracy for reliable sensing in critical environments\u003c\/li\u003e\n  \u003cli\u003eInterchangeable output: field-selectable 0 to 5 VDC or 4 to 20 mA\u003c\/li\u003e\n  \u003cli\u003e10K Type 2 thermistor provides simultaneous temperature sensing\u003c\/li\u003e\n  \u003cli\u003eOperates on 24 VAC or 24 VDC power\u003c\/li\u003e\n  \u003cli\u003eNEMA 4 and IP66 rated polycarbonate enclosure resists moisture and dust\u003c\/li\u003e\n  \u003cli\u003eBAPI Box 2 housing simplifies wiring access and field installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for duct-mount installation in commercial and industrial HVAC systems requiring combined humidity and temperature sensing. Compatible with building automation systems and controllers that accept 0 to 5 VDC or 4 to 20 mA analog inputs. Suitable for humidification, dehumidification, supply, discharge, return air, economizer, clean room, data center, process control, school, hospital, and office building applications.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed HVAC controls technician or building automation specialist familiar with low-voltage sensing circuits. Power down the air handling unit and de-energize the control panel before wiring. Select the desired output signal (0 to 5 VDC or 4 to 20 mA) prior to installation per the manufacturer wiring instructions. Follow NEC requirements for low-voltage control wiring and ensure the duct penetration is properly sealed around the probe to prevent air leakage.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Accuracy\u003c\/strong\u003e: 3 percent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 0 to 5 VDC or 4 to 20 mA (interchangeable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Element\u003c\/strong\u003e: 10K Type 2 Thermistor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: 24 VAC or 24 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMount Type\u003c\/strong\u003e: Duct\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: NEMA 4, IP66\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Polycarbonate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: Humidification, Dehumidification, Supply Air, Discharge Air, Return Air, Economizers, Clean Rooms, Data Centers, Process Control, Schools, Hospitals, Office Buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: BAPI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BA\/10K-2-H300-D-BB2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BAPI","offers":[{"title":"Default Title","offer_id":51283897680178,"sku":"BA\/10K2H300DBB2","price":227.11,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309279088.jpg?v=1781062681","url":"https:\/\/voomisupply.com\/products\/bapi-ba-10k-2-h300-d-bb2-duct-humidity-transmitter","provider":"Voomi Supply","version":"1.0","type":"link"}