{"product_id":"appleton-lb77-conduit-outlet-body-2-1-2-in-form-7","title":"Appleton LB77 Conduit Outlet Body 2-1\/2 in Form 7","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe APPLETON LB77 is a Form 7 LB-configuration conduit outlet body designed for use with 2-1\/2 inch rigid and IMC conduit systems. The body is constructed from zinc electroplated, chromate, and epoxy powder coated Grayloy iron, providing corrosion resistance in demanding environments. It features a 102 cubic inch internal capacity, two hubs positioned at 90 degrees, and threaded installation. The cover is secured using a wedge-lock clip design with captive pan-head stainless steel cover screws, and a neoprene gasket is included for wet location use. Licensed electricians and conduit installers working on commercial and industrial wiring systems handle installation of this fitting.\u003c\/p\u003e\n\u003cp\u003eThe LB77 is used in conduit runs that require a 90-degree change of direction with back-access for pulling conductors, splicing, or maintenance. Its flat-back design provides greater cubic content for easier wire pulling and more room for splicing, and fits flush against flat surfaces for a stable mount. The body is approved for use in wet locations when installed with the cast cover and gasket. It is listed under UL 514A\/514B and CSA C22.2, and meets NEMA FB-1 standards. This fitting is compatible with rigid steel conduit and IMC conduit installations in both commercial and industrial applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eLB configuration with 90-degree hub orientation and back-access opening for conductor pulling and splicing\u003c\/li\u003e\n  \u003cli\u003e102 cubic inch capacity supports conductor fill requirements in larger conduit runs\u003c\/li\u003e\n  \u003cli\u003eWedge-lock clip cover design allows easy removal without damaging the conduit body; cover screws and clips are captive\u003c\/li\u003e\n  \u003cli\u003eSmooth, rounded integral hub bushings protect conductor insulation during pulling\u003c\/li\u003e\n  \u003cli\u003eAccurately tapped, tapered threads provide tight, rigid joints and reliable ground continuity\u003c\/li\u003e\n  \u003cli\u003eApproved for wet location use; UL 514A\/514B and CSA C22.2 listed, NEMA FB-1 compliant\u003c\/li\u003e\n  \u003cli\u003eForm 7 design is dimensionally interchangeable with other Form 7 and FM7 bodies, gaskets, and covers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use on 2-1\/2 inch rigid steel conduit and IMC conduit with threaded installation. Form 7 dimensions are fully interchangeable with other FM7 and Form 7 conduit body units, gaskets, and covers from competing manufacturers.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation is performed by a licensed electrician in accordance with the NEC and applicable local codes. De-energize all circuits before opening the conduit body for conductor work. Use appropriate thread sealant rated for conduit fittings when making up threaded joints, and verify hub engagement meets code-required thread count. Do not overtighten cover screws; the wedge-lock clip system is designed to secure the cover without excessive torque.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: LB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eForm Type\u003c\/strong\u003e: Form 7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHub Size\u003c\/strong\u003e: 2-1\/2 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Hubs\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHub Location\u003c\/strong\u003e: 90 Degree\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccess Opening\u003c\/strong\u003e: Back\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Capacity\u003c\/strong\u003e: 102 cubic inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBody Dimensions\u003c\/strong\u003e: 10.5 inches L x 5.13 inches H\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Type\u003c\/strong\u003e: Threaded\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed On\u003c\/strong\u003e: Rigid\/IMC Conduit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBody Material\u003c\/strong\u003e: Zinc Electroplated\/Chromate\/Epoxy Powder Coated Grayloy Iron\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGasket Material\u003c\/strong\u003e: Neoprene\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCover Screw Material\u003c\/strong\u003e: Stainless Steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: UL 514A\/514B, CSA C22.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplicable Standard\u003c\/strong\u003e: NEMA FB-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Weight\u003c\/strong\u003e: 8.8 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Dimensions\u003c\/strong\u003e: 13 inches L x 6.5 inches W x 6.5 inches H\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: MX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: APPLETON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: LB77\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"APPLETON","offers":[{"title":"Default Title","offer_id":51283976552754,"sku":"LB77","price":182.43,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309279208.jpg?v=1781064793","url":"https:\/\/voomisupply.com\/products\/appleton-lb77-conduit-outlet-body-2-1-2-in-form-7","provider":"Voomi Supply","version":"1.0","type":"link"}