{"product_id":"american-standard-auhmb060acv3vb-modulating-gas-furnace","title":"American Standard AUHMB060ACV3VB Modulating Gas Furnace","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMERICAN STANDARD AUHMB060ACV3VB is a modulating natural gas furnace rated at 60,000 BTU\/h input and 57,000 BTU\/h output, delivering 97.3% AFUE efficiency for residential heating applications. It uses a variable-speed ECM blower motor and 3-stage modulating operation to match heat output precisely to load demand, reducing temperature swings and cycling noise. The unit is configured for upflow or horizontal-left installation and supports both direct-vent and non-direct-vent venting arrangements. Licensed HVAC technicians install and commission this furnace as part of a split or packaged system replacement or new construction install.\u003c\/p\u003e\n\u003cp\u003eThis furnace is suited for residential forced-air systems where high-efficiency, variable-capacity heating is specified. The modulating burner and variable-speed blower allow the unit to operate across a wide range of heating loads, making it appropriate for both smaller zones and whole-home applications. Airflow capability ranges from 791 to 1,063 CFM at 0.1 inch WG in heating mode and 832 to 1,326 CFM at 0.1 inch WG in cooling mode, supporting multi-season system configurations. It belongs to the AUHM-Modulating family from American Standard Heating and Air Conditioning.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e97.3% AFUE modulating operation for high-efficiency natural gas heating\u003c\/li\u003e\n  \u003cli\u003e3-stage burner with variable-speed ECM blower motor for precise load matching\u003c\/li\u003e\n  \u003cli\u003eUpflow and horizontal-left orientation supports flexible installation layouts\u003c\/li\u003e\n  \u003cli\u003eCompatible with both direct-vent and non-direct-vent flue configurations\u003c\/li\u003e\n  \u003cli\u003eWide airflow range: 791 to 1,326 CFM depending on mode and static pressure\u003c\/li\u003e\n  \u003cli\u003e2-inch diameter vent connection accommodates standard venting materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003ePart of the AUHM-Modulating family from American Standard Heating and Air Conditioning. Designed as an upflow or horizontal-left modulating natural gas furnace for residential forced-air systems requiring direct-vent or non-direct-vent installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54 or ANSI Z223.1), and the manufacturer installation instructions. Disconnect all electrical power and shut off the gas supply at the service valve before beginning any service or installation work. Verify vent pipe diameter, length, and termination clearances meet code requirements for the chosen venting method before startup. Do not attempt to convert this unit to LP gas without a manufacturer-approved conversion kit installed by a qualified technician.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBTU\/h Input\u003c\/strong\u003e: 60,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBTU\/h Output\u003c\/strong\u003e: 57,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 97.3% \/ 96.5%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency Rating\u003c\/strong\u003e: 90% +\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 115 VAC, 60 Hz, 1-Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull Load Amps (FLA)\u003c\/strong\u003e: 6.4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Horsepower\u003c\/strong\u003e: 1\/2 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow (Heating)\u003c\/strong\u003e: 791 to 1,063 CFM at 0.1 inch WG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow (Cooling)\u003c\/strong\u003e: 832 to 1,326 CFM at 0.1 inch WG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStaging\u003c\/strong\u003e: 3-Stage Modulating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Upflow \/ Horizontal Left\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting\u003c\/strong\u003e: Direct Vent \/ Non-Direct Vent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel Type\u003c\/strong\u003e: Natural Gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 3 Ton\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Family\u003c\/strong\u003e: AUHM-Modulating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: AMERICAN STANDARD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: AUHMB060ACV3VB\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMERICAN STANDARD","offers":[{"title":"Default Title","offer_id":51525257953586,"sku":"AUHMB060ACV3VB","price":3232.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/04e79038eaf58ffef1ea47df3f3cd9df.jpg?v=1785468662","url":"https:\/\/voomisupply.com\/products\/american-standard-auhmb060acv3vb-modulating-gas-furnace","provider":"Voomi Supply","version":"1.0","type":"link"}