{"product_id":"amana-dhp093j50ba-ptac-heat-pump-9200-btu-5-0-kw-r32","title":"Amana DHP093J50BA Ptac Heat Pump 9200 Btu 5.0 Kw R32","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMANA DHP093J50BA is a packaged terminal air conditioner (PTAC) with an integrated heat pump and electric backup heat strip, designed for through-the-wall installation in residential and commercial spaces such as hotels, apartments, and assisted living facilities. Operating on 208\/230 volt, 30 amp power, the unit delivers 9,200 to 9,300 BTU\/h of cooling at an EER of 11.4 and 7,900 to 8,100 BTU\/h of heat pump heating. A 5.0 kW electric backup heat strip provides up to 15,000 BTU\/h when the heat pump alone cannot meet the load. R32 refrigerant reduces Global Warming Potential compared to R410A. Licensed HVAC technicians perform this installation.\u003c\/p\u003e\n\u003cp\u003eThe DHP093J50BA fits a standard 42-inch PTAC sleeve and is suited for single-room climate control in hotels, motels, and multi-family residential buildings. Three fan speeds plus a fan-only mode give occupants flexibility. The unit supports control directly from the front panel or via a wired wall thermostat. Front Desk Control configuration allows temperature limiting for hospitality applications, restricting the minimum and maximum setpoints while still allowing guest adjustment. Automatic Emergency Heat switches to electric resistance heat if the heat pump compressor fails or if heating demand exceeds heat pump capacity. This replaces the DHP093A50AA, which used R410A refrigerant.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e11.4 EER cooling efficiency at both 208 and 230 volts\u003c\/li\u003e\n  \u003cli\u003eR32 refrigerant with lower Global Warming Potential than R410A\u003c\/li\u003e\n  \u003cli\u003e5.0 kW electric backup heat strip provides up to 15,000 BTU\/h at 230 volts\u003c\/li\u003e\n  \u003cli\u003eAutomatic Emergency Heat activates if compressor fails or heating load exceeds heat pump capacity\u003c\/li\u003e\n  \u003cli\u003eEvaporator Freeze Protection cycles the compressor off and fan on to prevent ice buildup\u003c\/li\u003e\n  \u003cli\u003eCondensate dispersion system directs excess moisture onto the outdoor coil for evaporation\u003c\/li\u003e\n  \u003cli\u003eWashable front-access filters and concealed front-panel screw for tamper resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eFits a standard 42-inch PTAC sleeve with interior dimensions of 42 inches wide by 16-1\/16 inches high by 14-1\/8 inches deep. Required wall cutout is 42-1\/4 inches wide by 16-1\/4 inches high. Sleeve and rear grille are not included and must be ordered separately. Directly replaces the DHP093A50AA R410A unit.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation instructions. Verify the dedicated 30 amp, 208\/230 volt circuit is de-energized before handling any electrical connections. A sleeve and rear grille are required for new installations and are not supplied with the unit. Do not operate the unit without a properly sized sleeve, as this affects both performance and structural integrity of the wall opening.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e: 9,200 BTU\/h at 208 volts \/ 9,300 BTU\/h at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEER\u003c\/strong\u003e: 11.4 at 208 volts and 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Pump Capacity\u003c\/strong\u003e: 7,900 BTU\/h at 208 volts \/ 8,100 BTU\/h at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectric Heat Strip\u003c\/strong\u003e: 4.8 kW at 208 volts \/ 5.0 kW at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectric Heating Capacity\u003c\/strong\u003e: 12,200 BTU\/h at 208 volts \/ 15,000 BTU\/h at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP (Heat Pump)\u003c\/strong\u003e: 3.4 at 208 volts and 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 208\/230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Cord\u003c\/strong\u003e: 30 amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Amps\u003c\/strong\u003e: 4.6 at 208 volts \/ 4.2 at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Watts\u003c\/strong\u003e: 810 at 208 volts \/ 820 at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectric Heating Amps\u003c\/strong\u003e: 20.1 at 208 volts \/ 22.3 at 230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R32\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow (CFM)\u003c\/strong\u003e: 300 low \/ 363 high\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDehumidification\u003c\/strong\u003e: 1.14 pints per hour\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan Speeds\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Type\u003c\/strong\u003e: Electronic\/Digital\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFresh Air Intake\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Size Required\u003c\/strong\u003e: 42 inches wide by 16-1\/16 inches high by 14-1\/8 inches deep\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWall Cutout Dimensions\u003c\/strong\u003e: 42-1\/4 inches wide by 16-1\/4 inches high\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 99.21 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ETL \/ AHRI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Star\u003c\/strong\u003e: No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: AMANA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: DHP093J50BA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMANA","offers":[{"title":"Default Title","offer_id":51284159496498,"sku":"DHP093J50BA","price":1395.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309279844.jpg?v=1781070108","url":"https:\/\/voomisupply.com\/products\/amana-dhp093j50ba-ptac-heat-pump-9200-btu-5-0-kw-r32","provider":"Voomi Supply","version":"1.0","type":"link"}