{"product_id":"aciq-ac-i-60ac14-ac-i-4860acl-21-g96vtn0802120-5-ton-80-000-btu-hvac-system-replaces-59tp6b080v21-20","title":"Aciq AC-I-60AC14 \/ AC-I-4860ACL-21 \/ G96VTN0802120 5 Ton 80,000 BTU HVAC System (Replaces 59TP6B080V21--20)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eAciq AC-I-60AC14 \/ AC-I-4860ACL-21 \/ G96VTN0802120 is a matched HVAC system that combines a 5 ton R32 condenser, a 21\" cased multi-positional evaporator coil, and an 80,000 BTU 96% AFUE variable-speed two-stage gas furnace. The condenser is pre-charged for R32 with a rotary compressor and single-stage operation. The furnace provides variable-speed ECM blower control and multi-positional installation for upflow, downflow, or horizontal configurations.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCondenser: AC-I-60AC14, 60,000 BTU (5 Ton), 13.8 SEER2, rotary compressor, pre-charged R32\u003c\/li\u003e\n  \u003cli\u003eCoil: AC-I-4860ACL-21, 21\" cased A-coil, factory-installed TXV, rated for 3.5â5 ton systems with 3\/8\" liquid and 3\/4\" suction lines\u003c\/li\u003e\n  \u003cli\u003eFurnace: G96VTN0802120, 80,000 BTU input, 96% AFUE, two-stage burner, variable-speed ECM blower, multi-positional\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eComplete matched R32 HVAC package with 5 ton condenser (13.8 SEER2), 21\" cased TXV evaporator coil, and 96% AFUE multi-positional gas furnace; designed for professional installation and R32 compatibility.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ACIQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: AC-I-60AC14 \/ AC-I-4860ACL-21 \/ G96VTN0802120\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Aciq\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel \/ Package\u003c\/strong\u003e: AC-I-60AC14 \/ AC-I-4860ACL-21 \/ G96VTN0802120\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem type\u003c\/strong\u003e: Matched condenser, evaporator coil, and gas furnace system\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser model\u003c\/strong\u003e: AC-I-60AC14\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser cooling capacity\u003c\/strong\u003e: 60,000 BTU (5 Ton)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser SEER2\u003c\/strong\u003e: 13.8\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser EER2\u003c\/strong\u003e: 11.7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser decibel level\u003c\/strong\u003e: 60 dBA (approx.)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser refrigerant type\u003c\/strong\u003e: R32 (A2L)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser refrigerant charge\u003c\/strong\u003e: 102.29 oz.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser compressor type\u003c\/strong\u003e: Rotary\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser stages\u003c\/strong\u003e: Single stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser electrical\u003c\/strong\u003e: 208\/230 V, 1 Phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser breaker requirements\u003c\/strong\u003e: Max 50 Amps, Min 33 Amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser dimensions (H x W x D)\u003c\/strong\u003e: 32.87\" x 29.13\" x 29.13\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser weight\u003c\/strong\u003e: 193 lb\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil model\u003c\/strong\u003e: AC-I-4860ACL-21\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil tonnage rating\u003c\/strong\u003e: 3.5 to 5 Ton\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil style\u003c\/strong\u003e: A-Coil (cased)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil cabinet width\u003c\/strong\u003e: 21\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil refrigerant\u003c\/strong\u003e: R32\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil liquid line size\u003c\/strong\u003e: 3\/8\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil suction line size\u003c\/strong\u003e: 3\/4\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil factory metering device\u003c\/strong\u003e: TXV (factory-installed)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil dimensions (H x W x D)\u003c\/strong\u003e: 27.80\" x 21.00\" x 21.02\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil weight\u003c\/strong\u003e: 87 lb\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace model\u003c\/strong\u003e: G96VTN0802120\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace heating BTU (input)\u003c\/strong\u003e: 80,000 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace AFUE\u003c\/strong\u003e: 96%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace blower motor\u003c\/strong\u003e: Variable speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace burner stages\u003c\/strong\u003e: Two-stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace maximum CFM\u003c\/strong\u003e: 2005\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace electrical\u003c\/strong\u003e: 120 V, 1 Phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace configuration\u003c\/strong\u003e: Multi-positional (Upflow \/ Downflow \/ Horizontal)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace exhaust flue requirement\u003c\/strong\u003e: Plastic \/ PVC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace dimensions (H x W x D)\u003c\/strong\u003e: 35.00\" x 21.00\" x 29.50\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFurnace weight\u003c\/strong\u003e: 156 lb\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAHRI certificate number (furnace)\u003c\/strong\u003e: 213148556\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel type\u003c\/strong\u003e: Natural Gas (field-convertible to Propane with optional LP kit)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnergy Star\u003c\/strong\u003e: Yes (furnace listed as Energy Star)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRequirements\u003c\/strong\u003e: Compatible indoor equipment required for R32 condenser; refrigerant leakage detection system required for R32 A2L refrigerant pairing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEquivalent \/ replacement models\u003c\/strong\u003e: Carrier 59TP6B080V21--20; Tempstar F96VTN0802120A; Bryant 926TB60080V21\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ACIQ","offers":[{"title":"Default Title","offer_id":51506779619634,"sku":"AC-I-60AC14 \/ AC-I-4860ACL-21 \/ G96VTN0802120","price":4725.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/315467193.jpg?v=1784930559","url":"https:\/\/voomisupply.com\/products\/aciq-ac-i-60ac14-ac-i-4860acl-21-g96vtn0802120-5-ton-80-000-btu-hvac-system-replaces-59tp6b080v21-20","provider":"Voomi Supply","version":"1.0","type":"link"}