{"product_id":"aci-a-rh2-cp-r-room-humidity-sensor-w-10k-ii-temp","title":"Aci A\/RH2-CP-R Room Humidity Sensor w\/10K II Temp","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ACI A\/RH2-CP-R is a room relative humidity sensor with 10K Type II temperature sensing. It features a thermoset polymer capacitive sensing element with a hydrophobic filter for moisture resistance. DIP switches allow selection of the desired output signal, and it can be powered by AC or DC power sources.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePopular room housing\u003c\/li\u003e\n  \u003cli\u003eFive-year warranty\u003c\/li\u003e\n  \u003cli\u003e24 VDC or 24 VAC power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis sensor is designed for humidification, dehumidification, and monitoring indoor space humidity in various applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ACI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A\/RH2-CP-R\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Room\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: 2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Sensor Type\u003c\/strong\u003e: 10K Type II\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material\u003c\/strong\u003e: Poly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Element\u003c\/strong\u003e: 10K Type 2 Thermistor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e: 4 - 20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: NEMA 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: 24 VAC,24 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Humidification,Dehumidification,Monitoring Indoor Space Humidity,Clean Rooms,Hospitals,Process Control,Laboratories,Museums,Schools,Office Buildings,Data Centers,ESD (Anti-Static) Control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMount\u003c\/strong\u003e: Room\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRH Supply Voltage (Reverse Polarity Protected)\u003c\/strong\u003e: 4-20 mA \/\t0-5 VDC \/ \t0-10 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRH Output Signal\u003c\/strong\u003e: 2-wire:\n4 - 20 mA (Factory Default) \/\n3-wire:\n0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRH Measurement Range\u003c\/strong\u003e: 0-100%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating RH Range\u003c\/strong\u003e: 0 to 95% RH, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRH Stability | Repeatability | Sensitivity\u003c\/strong\u003e: Less than 2% drift \/ 5 years | 0.5% RH | 0.1% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Thermistor Resistive Output @ 77°F (25°C) (Lead Wire Colors) Non-Linear NTC\u003c\/strong\u003e: RHx-CP Series (Type II): 10KΩ (White\/Green)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Type\u003c\/strong\u003e: Wall Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Element\u003c\/strong\u003e: 2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Ouput\u003c\/strong\u003e: 4-20 mA, 0-5 VDC, or 0-10 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Element\u003c\/strong\u003e: 10K Type II\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCO2 Element\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint\u003c\/strong\u003e: No Setpoint\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverride\u003c\/strong\u003e: No Override\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Plastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 122669\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ACI-Automation Components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: RH with Resistive Temperature Output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily Series\u003c\/strong\u003e: ACI-Automation Components HVAC Sensors, RH with Resistive Temperature Output Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e: Room, 2pct.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput\u003c\/strong\u003e: 15-40 VDC, 18-28 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 0-100 % RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComments\u003c\/strong\u003e: 4-20mA Default - 0-5 VDC or 0-10 VDC Output Selectable via Dip Switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGross Weight\u003c\/strong\u003e: 0 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC Code\u003c\/strong\u003e: 41110000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Automation Components Inc (ACI)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: EA\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ACI","offers":[{"title":"Default Title","offer_id":51162082509106,"sku":"A\/RH2-CP-R","price":319.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/306248990.png?v=1778890112","url":"https:\/\/voomisupply.com\/products\/aci-a-rh2-cp-r-room-humidity-sensor-w-10k-ii-temp","provider":"Voomi Supply","version":"1.0","type":"link"}