{"product_id":"aci-a-fs-3-spdt-freeze-stat-manual-reset-10ft","title":"Aci A\/FS-3 Spdt Freeze Stat - Manual Reset 10ft","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ACI A\/FS-3 SPDT Freeze Stat is a low limit controller designed for HVAC equipment needing low-temperature cutout protection to prevent cooling coils from freezing. It should be mounted between the heating and cooling coils on the supply side of the fan unit. It responds to the lowest temperature sensed along any 1 foot section of the sensing element.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 6, 10, and 20 foot length capillaries\u003c\/li\u003e\n  \u003cli\u003eAdjustable set-point\u003c\/li\u003e\n  \u003cli\u003eManual reset and automatic reset versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe ACI SPDT Freeze Stat has manual and automatic reset versions, as well as models that feature one or two sets of SPDT contacts. Numerous capillary lengths are also available.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ACI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A\/FS-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Type\u003c\/strong\u003e: Manual\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Low Temp Cutout Controller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Type\u003c\/strong\u003e: Copper Remote Bulb\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e: SPDT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint Range\u003c\/strong\u003e: 14-54 F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Temperature\u003c\/strong\u003e: 131 F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapillary Length\u003c\/strong\u003e: 10 FT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Switching\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan Switching\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Low Limit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDifferential\u003c\/strong\u003e: 1.8F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControls Outputs\u003c\/strong\u003e: 1 Set SPDT Contacts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Element\u003c\/strong\u003e: Vapor-filled, copper capillary tube\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e: A\/FS-1, -3, -5:\none SPDT Form 1C Relay\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Rating\u003c\/strong\u003e: 250 VAC, 15 (8) A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Rating\u003c\/strong\u003e: NEMA 1 IP40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 14\nto 194\n0F (-10\nto 65\n0C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e: 0 to 95%, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 106291\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ACI-Automation Components\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: FS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily Series\u003c\/strong\u003e: ACI-Automation Components Controllers, FS Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e: Spdt W\/Man Reset 14-54Degf 10ft.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Voltage\u003c\/strong\u003e: 250 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: Switch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint Temp Range\u003c\/strong\u003e: 14-54 \n0F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Element\u003c\/strong\u003e: Vapor Filled Copper Capillary\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e: Terminal with wire-retaining screws\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasured Values\u003c\/strong\u003e: Temperature in air\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput signal frost protection switch note\u003c\/strong\u003e: 1 x SPDT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwitch\u003c\/strong\u003e: (1)SPDT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Functionality\u003c\/strong\u003e: Manual Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ACI","offers":[{"title":"Default Title","offer_id":51161887605042,"sku":"A\/FS-3","price":345.81,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/306248952.jpg?v=1778885033","url":"https:\/\/voomisupply.com\/products\/aci-a-fs-3-spdt-freeze-stat-manual-reset-10ft","provider":"Voomi Supply","version":"1.0","type":"link"}