{"product_id":"aci-a-fls-06-a-freeze-stat-fls-6-feet-capillary-automatic-reset-4-wires-2-circuits","title":"Aci A\/FLS-06-A Freeze Stat (FLS), 6 feet Capillary, Automatic Reset, 4 Wires, 2 Circuits","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ACI A\/FLS-06-A freeze stat is a low limit controller designed for HVAC equipment needing low-temperature cutout protection to prevent cooling coils from freezing. It should be mounted between heating and cooling coils on the supply side of the fan unit and responds to the lowest temperature sensed along any 1 foot section of the sensing element.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAvailable with 6, 10, and 20 foot length capillaries\u003c\/li\u003e\n  \u003cli\u003eAdjustable set-point\u003c\/li\u003e\n  \u003cli\u003eManual reset and automatic reset versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis freeze stat protects heating and cooling coils and features a low temperature limit switch for applications where temperature stratification may occur.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ACI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A\/FLS-06-A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Switching\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan Switching\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Low Limit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDifferential\u003c\/strong\u003e: 1.8F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControls Outputs\u003c\/strong\u003e: 2 Sets SPDT Contacts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Element\u003c\/strong\u003e: Vapor-filled, copper capillary tube\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Rating\u003c\/strong\u003e: 250 VAC, 15 (8) A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint Range\u003c\/strong\u003e: 14\n\n to 54\n\nF (-10\n\n to 12\n\nC) field adjustable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint Differential\u003c\/strong\u003e: 1.8\n\nF (1.0\n\nC), fixed for auto reset\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSetpoint Safety Lock\u003c\/strong\u003e: 35.6\n\nF (2.0\n\nC) factory set; field adjustable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Rating\u003c\/strong\u003e: NEMA 1 IP40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 14\n\n to 194\n\nF (-10\n\n to 65\n\nC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e: 0 to 95%, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermostat Type\u003c\/strong\u003e: Self-contained, electromechanical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Media\u003c\/strong\u003e: Temperature in air\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Trip Point Range\u003c\/strong\u003e: 15\n\nF to 55\n\nF (-9\n\nC to 13\n\nC); Factory set with Stop at 35\n\nF(1.7\n\nC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Options\u003c\/strong\u003e: Model Dependent: Manual or Automatic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproximate Switching Differential\u003c\/strong\u003e: Auto Reset only: Approximately 5\n\nF (2.8\n\nC), Non-adjustable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Form\u003c\/strong\u003e: 4 Wires, 2 Circuits (Two simultaneously switching contacts (Circuits))\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Type\u003c\/strong\u003e: Line to M2 (Main): Open on Temperature Drop\nLine to M1 (Auxiliary\/Alarm): Close on Temperature Drop\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Connections\u003c\/strong\u003e: Screw Terminals; Copper wire only rated to 90\n\nC (194\n\nF) minimum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Response\u003c\/strong\u003e: To lowest temperature sensed along any 14 to 16\n\n (35.6 to 40.6 cm) length of sensing element\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Capillary Material\u003c\/strong\u003e: Copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Capillary Length\u003c\/strong\u003e: Model Dependent: 6' (1.83m), 10' (3.05m), 20' (6.10m), 50' (15.24m)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Capillary Diameter\u003c\/strong\u003e: 0.125\n\n (3.18 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: NEMA 1 (IP10)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e: Steel, galvanized\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Knockouts\u003c\/strong\u003e: conduit knockout\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: 0 to 140\n\nF (-18 to 60\n\nC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e: -40 to 158\n\nF (-40 to 70\n\nC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensing Capillary Overload Temperature\u003c\/strong\u003e: 400\n\nF (204.4\n\nC) maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating RH Range\u003c\/strong\u003e: 0 to 95% RH, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReset Functionality\u003c\/strong\u003e: Auto Reset\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapillary Length\u003c\/strong\u003e: 6'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ACI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComponent\u003c\/strong\u003e: Freeze Stat\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Automation Components Inc (ACI)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A\/FLS-06-A\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ACI","offers":[{"title":"Default Title","offer_id":51161754304818,"sku":"A\/FLS-06-A","price":482.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/306248834.jpg?v=1778880744","url":"https:\/\/voomisupply.com\/products\/aci-a-fls-06-a-freeze-stat-fls-6-feet-capillary-automatic-reset-4-wires-2-circuits","provider":"Voomi Supply","version":"1.0","type":"link"}