{"product_id":"abb-su201m-k3-miniature-circuit-breaker-1p-3a-480v","title":"Abb SU201M-K3 Miniature Circuit Breaker 1P 3A 480V","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB SU201M-K3 is a single-pole miniature circuit breaker (MCB) rated for 3 amps with a K-curve trip characteristic and a 10 kA interrupting capacity. It is listed under UL 489 and rated for use at 480 volts and 277 volts, making it suitable for both line-to-line and line-to-neutral applications in North American electrical distribution systems. The K-curve characteristic means it tolerates higher inrush currents before tripping, which is appropriate for loads with significant startup surge. Licensed electricians install this device in panelboards, load centers, and control panel assemblies where branch-circuit overcurrent protection is required.\u003c\/p\u003e\n\u003cp\u003eThis MCB is used in commercial and light industrial electrical distribution applications where a single-pole breaker is needed on a 480V or 277V system. Typical installations include lighting branch circuits, control circuits, and other single-phase loads that require UL 489 listed overcurrent protection. Its K-curve rating makes it well suited to motor control or transformer-fed circuits where high inrush current at startup would otherwise cause nuisance tripping on a standard B or C curve device.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eK-curve trip characteristic for high-inrush load applications\u003c\/li\u003e\n  \u003cli\u003e10 kA interrupting capacity at rated voltage\u003c\/li\u003e\n  \u003cli\u003eSingle-pole design rated for 3 amps continuous\u003c\/li\u003e\n  \u003cli\u003eDual voltage rating: 480 volts line-to-line and 277 volts line-to-neutral\u003c\/li\u003e\n  \u003cli\u003eUL 489 listed for branch-circuit overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation single-pole MCB for UL 489 listed panelboard and control panel applications requiring a K-curve breaker at 480V or 277V.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed electrician in accordance with the National Electrical Code (NEC) and applicable local codes. De-energize the panel or distribution assembly completely before installing or replacing the breaker. Verify that the bus system and panelboard are rated and approved for use with DIN-rail or snap-in MCBs of this type before installation. Do not exceed the breaker ampere rating when sizing branch-circuit conductors.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmpere Rating\u003c\/strong\u003e: 3 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 480 volts \/ 277 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Curve\u003c\/strong\u003e: K\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eListing\u003c\/strong\u003e: UL 489\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SU201M-K3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51383092379954,"sku":"SU201M-K3","price":49.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/312673307.png?v=1782587875","url":"https:\/\/voomisupply.com\/products\/abb-su201m-k3-miniature-circuit-breaker-1p-3a-480v","provider":"Voomi Supply","version":"1.0","type":"link"}