{"product_id":"abb-su201m-c2-ul489-mcb-1p-c-2a-480","title":"Abb SU201M-C2 UL489 MCB 1P C 2A 480","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB SU201M-C2 is a miniature circuit breaker with a rated current of 2 Amps. This 1-pole breaker has an interrupt rating of 10 kA and a C trip curve. It is suitable for voltages up to 277\/Y480 VAC and 48\/96 VDC. Designed for DIN rail mounting with finger-safe and multi-function terminals, it is UL 489 and CSA 22.2 No. 5 compliant.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMiniature Circuit Breaker\u003c\/li\u003e\n  \u003cli\u003eRated Current 2 Amps\u003c\/li\u003e\n  \u003cli\u003e1 Pole\u003c\/li\u003e\n  \u003cli\u003eInterrupt Rating 10 kA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe ABB SU201M-C2 is ideal for branch circuit protection and provides energy limiting circuit protection.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SU201M-C2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Denmark\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 17.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 111 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 69 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 2 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 277\/480 VAC, 96 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 2 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: CSA 22.2 No. 5,EN 60947-2,UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: Branch Circuit Protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Screw\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Size\u003c\/strong\u003e: 16-4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 1 Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e: -25 to 55 degrees C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 55 degrees C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e: 3 Degree of Pollution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel \/ MPN\u003c\/strong\u003e: 2CDS271337R0024\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: CIRCUIT_BREAKER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: (277 V AC) \/ (48 V DC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 2 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial Features\u003c\/strong\u003e: SU201M-C2 Miniature Circuit Breaker C-Char.; 10kA; 2A; 1P UL489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e: C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth [Specifications]\u003c\/strong\u003e: 69 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards [Specifications]\u003c\/strong\u003e: CSA, IEC, UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurve Type [Specifications]\u003c\/strong\u003e: C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. AIR Rating [Specifications]\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Voltage Rating [Specifications]\u003c\/strong\u003e: 230\/277V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating [Specifications]\u003c\/strong\u003e: 48V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection [Specifications]\u003c\/strong\u003e: Busbar; Failsafe Bi-directional Cylinder-lift Terminal; Double Clamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Mounting Style [Specifications]\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: UL 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCharacteristic\u003c\/strong\u003e: C Curve\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 1-15 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SU201M-C2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SU200M Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection\u003c\/strong\u003e: Screw Connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 18 to 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: IP20\/IP40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN Rail Mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature\u003c\/strong\u003e: -25 to 55 deg C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVolts DC\u003c\/strong\u003e: 48\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: SU200M\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily Series\u003c\/strong\u003e: ABB Circuit Breakers, SU200M Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Voltage\u003c\/strong\u003e: 240 VAC, 277\/480 VAC, 48 VDC, 96 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Curve\u003c\/strong\u003e: C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Unit\u003c\/strong\u003e: Fixed Thermal \/ Fixed Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNeutral Pole\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch\u003c\/strong\u003e: Optional\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShunt Trip\u003c\/strong\u003e: Optional\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUndervoltage Release\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm Switch\u003c\/strong\u003e: Optional\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL Standard\u003c\/strong\u003e: 489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Type\u003c\/strong\u003e: AC\/DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber in Pack\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":50943792677170,"sku":"SU201M-C2","price":188.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/294639843.jpg?v=1772478743","url":"https:\/\/voomisupply.com\/products\/abb-su201m-c2-ul489-mcb-1p-c-2a-480","provider":"Voomi Supply","version":"1.0","type":"link"}