{"product_id":"abb-pam3015-ld-ctr-mcb-150a-30-60","title":"Abb PAM3015 Ld Ctr MCB 150A 30\/60","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB PAM3015 is a ReliaHome load center designed for fast installation and reliability. It works seamlessly with residential circuit breakers. This single-phase load center has a 150 A amperage, 60 circuits, and an interrupt rating of 22kAIC. It features a NEMA 1 enclosure for indoor use.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for fast installation\u003c\/li\u003e\n  \u003cli\u003eReliable performance\u003c\/li\u003e\n  \u003cli\u003eOptimizes stock with seamless integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe ABB PAM3015 load center ensures reliable power distribution in residential settings with its easy installation and seamless integration.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: PAM3015\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Load Centers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrouping\u003c\/strong\u003e: Single Phase - USA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e# Branch Circuit \u0026lt;250A\u003c\/strong\u003e: 30\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\" Space\u003c\/strong\u003e: 30\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/2\" Space\u003c\/strong\u003e: 0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 150 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Style\u003c\/strong\u003e: Plug-On Neutral\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoor\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e: NEMA 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Installed Ground Kit\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeed\u003c\/strong\u003e: Either\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput\/Output Voltage\u003c\/strong\u003e: 120\/240V ac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 22 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity Rating\u003c\/strong\u003e: 22kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Center Type\u003c\/strong\u003e: P-Series (PON)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeter Socket Options: 200 Amp Main Breaker Installed\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeter Socket Options: High Amp Mode\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e: NEMA 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo of Circuits\u003c\/strong\u003e: 60\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1 Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eService \u0026amp; Voltage\u003c\/strong\u003e: 1 Phase, 3 Wire, 120\/240V ac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWires\u003c\/strong\u003e: 3 Wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL\/CUL Listing\u003c\/strong\u003e: UL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: P-Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e: 3-Wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e: 60\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 150 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120, 240 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaker Type\u003c\/strong\u003e: Main Circuit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e: 30\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber Of Feeders\u003c\/strong\u003e: Either\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e: 120\/240V ac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC\u003c\/strong\u003e: 39121101\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":51150462976306,"sku":"PAM3015","price":239.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305950024.png?v=1778612721","url":"https:\/\/voomisupply.com\/products\/abb-pam3015-ld-ctr-mcb-150a-30-60","provider":"Voomi Supply","version":"1.0","type":"link"}