{"title":"FIRE-LITE","description":null,"products":[{"product_id":"honeywell-lcd-80f-honeywell-lcd-80f-remote-fire-annunciator","title":"Fire-Lite LCD-80F Remote Annunciator 24 V DC (80-character)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Fire-Lite LCD-80F is a remote annunciator for Fire-Lite fire alarm control panels (FACP) that mirrors panel display information on an 80-character backlit LCD. It reports device type identifiers, individual point alarm\/trouble\/supervisory status, zone and custom alpha labels, and shows time and date. The unit connects via EIA-485 (up to 32 annunciators), may be powered by the host FACP or a 24 V DC supply, includes control switches and system status LEDs, and uses plug-in terminal blocks for installation; it can be located up to 6,000 ft (1,828.8 m) from the host panel.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e80-character backlit LCD showing device type identifiers, individual point status, zone and custom alpha labels, and time\/date\u003c\/li\u003e\n  \u003cli\u003eEIA-485 connectivity supporting up to 32 annunciators; powered from host FACP or remote 24 V DC\u003c\/li\u003e\n  \u003cli\u003eControl switches (acknowledge, signal silence, drill, reset with enable key), system status LEDs, plug-in terminal blocks, semi-flush or surface mount options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003e80-character backlit LCD; EIA-485 connectivity for up to 32 annunciators; 24 V DC power options; semi-flush or surface mount; UL, FM, CSFM and MEA certifications\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: LCD-80F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Fire-Lite\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell International, Inc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: LCD-80F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Remote Annunciator \/ Annunciator Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: 80-character backlit LCD\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay Details\u003c\/strong\u003e: Device type identifiers, individual point alarm\/trouble\/supervisory status, zone and custom alpha labels, time and date field\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Options\u003c\/strong\u003e: Powered from host FACP or remote 24 V DC power supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Switches\u003c\/strong\u003e: System acknowledge, signal silence, drill, reset (reset operable via enable key)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e: System status LEDs for power, alarm, trouble, supervisory, alarm silenced\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Sounder\u003c\/strong\u003e: Local piezo sounder with alarm and trouble resound\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnectivity\u003c\/strong\u003e: EIA-485 terminal port\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnnunciators Per FACP\u003c\/strong\u003e: Up to 32 annunciators\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Distance From FACP\u003c\/strong\u003e: 6,000 ft (1,828.8 m)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgramming Required\u003c\/strong\u003e: No programming required\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Plug-in terminal blocks for ease of installation and service\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Options\u003c\/strong\u003e: Semi-flush to minimum 2.188 inch three-gang electrical box or surface mount with SBB-3 surface backbox\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H inches)\u003c\/strong\u003e: 5.8 x 4 x 2.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e: Fire-Lite MS-9200UD Series, MS-9600 Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL Listed; FM Approved; CSFM; MEA Listed; ULC; NYFD; Seismic\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":50129706582322,"sku":"LCD-80F","price":2102.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/50356c280677bd6834c4956abc286fcc.jpg?v=1790976911"},{"product_id":"fire-lite-hw-av-lte-m-2-commercial-fire-clss-dual-path-ethernet-cellular-at-t-verizon-lte-m-alarm-communicator","title":"FIRE-LITE HW-AV-LTE-M-2 Commercial Fire CLSS Dual-Path Ethernet Cellular AT\u0026T Verizon LTE-M Alarm Communicator","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE HW-AV-LTE-M-2 is a commercial fire CLSS dual-path Ethernet cellular alarm communicator compatible with universal fire alarm control panels. It uses AT\u0026amp;T and Verizon LTE-M cellular networks. The communicator is UL and ETL listed, ensuring compliance with safety standards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-path Ethernet cellular communication\u003c\/li\u003e\n  \u003cli\u003eCompatible with universal fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eUtilizes AT\u0026amp;T and Verizon LTE-M networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC Code\u003c\/strong\u003e: 46191505\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard Information\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: HW-AV-LTE-M-2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":50996644217138,"sku":"HW-AV-LTE-M-2","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/ce84e05af894f9bc80d08bf89cdd2c71.jpg?v=1790920029"},{"product_id":"fire-lite-bg-12lx-dual-action-addressable-pull-station-with-key-locking-feature","title":"FIRE-LITE BG-12LX Dual Action Addressable Pull Station Key Locking","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE BG-12LX is a dual-action pull station with an addressable interface for Fire-Lite's addressable fire alarm control panels (FACPs). The control panel can display the exact location of the activated manual station. It connects with two wires to one of the control panel SLC loops and features key locking.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintenance personnel can open the station for inspection and address setting without causing an alarm condition\u003c\/li\u003e\n  \u003cli\u003eBuilt-in bicolor LED, flashes in normal operation and latches steady red when in alarm\u003c\/li\u003e\n  \u003cli\u003eHandle latches in down position and the word ACTIVATED appears to clearly indicate the station has been operated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAddressable interface\u003c\/li\u003e\n  \u003cli\u003eDual-action design\u003c\/li\u003e\n  \u003cli\u003eKey locking\u003c\/li\u003e\n  \u003cli\u003eMeets ADA guidelines\u003c\/li\u003e\n  \u003cli\u003eSurface or semi-flush mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: PC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e: 120�F (48.9�C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrint\/Message\u003c\/strong\u003e: Pull Down, Push In\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: Red\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNational Stock Number\u003c\/strong\u003e: 6350-01-582-5247\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard Information\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BG-12LX\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":50996970357042,"sku":"BG-12LX","price":170.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/cbd3149c61b7e48fe7f1d9a7c9229322.jpg?v=1790920155"},{"product_id":"fire-lite-h365-addressable-heat-detector-with-base","title":"Fire-lite h365 Addressable Heat Detector with Base","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE h365 is an addressable heat detector designed for use in intelligent fire alarm systems. It monitors for abnormal temperature conditions using both fixed temperature and rate-of-rise detection technologies, providing reliable response to rapid and gradual heat buildup scenarios. The detector communicates with the control panel over a two-wire signaling line circuit and occupies a single device address, enabling precise alarm location identification across the protected area. A low-profile housing keeps the unit unobtrusive in finished interiors, and the sensing chamber is designed to resist contamination for stable long-term performance. The unit ships with its mounting base included.\u003c\/p\u003e\n\u003cp\u003eThe h365 is suited for commercial and light industrial applications where intelligent heat detection is required. Typical installations include office buildings, educational facilities, hospitality environments, and industrial spaces. It integrates into intelligent life safety infrastructures that use addressable signaling line circuits, allowing the control panel to pinpoint the exact device location at alarm. The detector fits into a standard base that supports secure locking and straightforward removal during routine inspection or maintenance cycles.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDual detection technology: fixed temperature and rate-of-rise sensing for response to both slow and fast heat buildup\u003c\/li\u003e\n  \u003cli\u003eAddressable operation over a two-wire signaling line circuit with single device address assignment\u003c\/li\u003e\n  \u003cli\u003eLow-profile housing suitable for finished commercial and institutional interiors\u003c\/li\u003e\n  \u003cli\u003eContamination-resistant sensing chamber supports stable long-term operation\u003c\/li\u003e\n  \u003cli\u003eIntegrated status indicator provides clear standby and alarm state visibility\u003c\/li\u003e\n  \u003cli\u003eIncludes mounting base with secure locking and tool-assisted removal for maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style addressable heat detector for use with intelligent fire alarm control panels that support two-wire signaling line circuit devices.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the signaling line circuit at the control panel before connecting or removing the detector. Assign the device address according to the system documentation before mounting the detector into the base. Verify normal standby status on the control panel after installation and before returning the system to service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection Technology\u003c\/strong\u003e: Fixed temperature and rate-of-rise\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Type\u003c\/strong\u003e: Two-wire signaling line circuit (SLC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing\u003c\/strong\u003e: Single device address, addressable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Profile\u003c\/strong\u003e: Low-profile\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: h365\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51524572053810,"sku":"H365","price":93.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/d020a6cf0f3ddf9ab8c439e0d533c0ec.jpg?v=1785452045"},{"product_id":"fire-lite-sd365r-addressable-photoelectric-smoke-detector","title":"Fire-lite sd365r Addressable Photoelectric Smoke Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE sd365r is an addressable, plug-in photoelectric smoke detector with remote test capability, designed for use with DNR and DNRW remote test accessories. It is part of the SD365 Series, which features an enhanced optical sensing chamber engineered to detect smoke from a wide range of combustion sources in compliance with current fire code standards. The sd365r is suited for installation in commercial and residential life-safety systems where addressable detection and remote testing access are required. Licensed fire alarm technicians and low-voltage contractors handle installation and commissioning.\u003c\/p\u003e\u003cp\u003eThe sd365r fits into addressable fire alarm systems using the LiteSpeed protocol or CLIP protocol depending on the finish selected. The white finish version supports LiteSpeed protocol only, while the ivory finish version supports both CLIP and LiteSpeed protocols. This makes the sd365r adaptable across a range of addressable fire alarm control panel configurations. It is typically installed in ceilings of commercial buildings, schools, healthcare facilities, and multi-unit residential structures where code requires addressable detection with remote test functionality.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAddressable plug-in design for compatibility with addressable fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eEnhanced optical sensing chamber for detection of smoke from a broad range of combustion sources\u003c\/li\u003e\n\u003cli\u003eRemote test capability for use with DNR and DNRW remote test accessories\u003c\/li\u003e\n\u003cli\u003eAvailable in white (LiteSpeed protocol only) and ivory (CLIP and LiteSpeed protocols)\u003c\/li\u003e\n\u003cli\u003eContemporary low-profile design suitable for visible installation in finished spaces\u003c\/li\u003e\n\u003cli\u003ePart of the SD365 Series, which includes photo-only and photo-thermal variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eThe sd365r is designed for use with DNR and DNRW remote test accessories and is compatible with addressable fire alarm systems supporting LiteSpeed protocol (white finish) or both CLIP and LiteSpeed protocols (ivory finish).\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel circuit before connecting or removing the detector head from its base. Verify protocol compatibility between the detector finish selected and the addressable control panel before installation. Follow the manufacturer wiring and address-setting documentation provided with the panel and detector.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Type\u003c\/strong\u003e: Photoelectric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: LiteSpeed (white); CLIP and LiteSpeed (ivory)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-in addressable base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Test\u003c\/strong\u003e: Compatible with DNR and DNRW accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SD365\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sd365r\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525244584242,"sku":"SD365R","price":110.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/e00e0851f0b393109f975b9ca0c7fbea.jpg?v=1785468311"},{"product_id":"fire-lite-sb-io-surface-back-box-for-bg-12-pull-station","title":"Fire-lite sb-io Surface Back Box for BG-12 Pull Station","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE sb-io is a surface-mount back box designed for use with the BG-12 manual pull station. This enclosure provides a proper mounting surface for the pull station in locations where flush or recessed installation is not practical. Constructed as a plastic enclosure, the sb-io supports both indoor and outdoor installation environments. Fire alarm technicians and life safety contractors install this back box as part of a code-compliant pull station assembly, ensuring the BG-12 is securely mounted and properly positioned for occupant access.\u003c\/p\u003e\n\u003cp\u003eThe sb-io is suited for surface-mount applications in commercial and light industrial facilities where the BG-12 manual pull station is part of the fire alarm system. Typical installations include locations with exposed conduit runs or masonry walls where recessed mounting is not feasible. The enclosure accommodates indoor and outdoor environments, making it a practical solution for covered exterior locations such as building egress points, stairwells, and covered walkways.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSurface-mount design for locations where flush installation is not practical\u003c\/li\u003e\n  \u003cli\u003eCompatible with the BG-12 manual pull station\u003c\/li\u003e\n  \u003cli\u003eRated for both indoor and outdoor installation environments\u003c\/li\u003e\n  \u003cli\u003ePlastic construction for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eSupports code-compliant pull station mounting per NFPA 72 installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with the FIRE-LITE BG-12 manual pull station as a surface-mount back box enclosure.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or qualified life safety contractor in accordance with NFPA 72 and applicable local codes. Disable the fire alarm control panel or place it in test mode before beginning installation to prevent unwanted alarms. Secure the back box to the mounting surface before attaching the BG-12 pull station, and verify all conduit entries are properly sealed for outdoor installations.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Type\u003c\/strong\u003e: Surface mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment Rating\u003c\/strong\u003e: Indoor and outdoor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Plastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Device\u003c\/strong\u003e: BG-12 manual pull station\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sb-io\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525369168178,"sku":"SB-IO","price":28.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/17efe2c218509eb855bac4768204dba9.jpg?v=1785471915"},{"product_id":"fire-lite-flt-mdf-300-dual-addressable-monitor-module","title":"Fire-lite flt-mdf-300 Dual Addressable Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE flt-mdf-300 is a dual addressable monitor module designed for intelligent, two-wire fire alarm systems. It supervises and monitors initiating device circuits (IDCs), supporting dry-contact input devices such as conventional heat detectors, manual pull stations, and two-wire smoke detectors. The module provides two independent IDCs at two separate, consecutive addresses on the signaling line circuit. A single panel-controlled LED provides local status indication. Licensed fire alarm technicians and low-voltage contractors install this module as part of addressable system expansions or new construction fire alarm installations.\u003c\/p\u003e\u003cp\u003eThis module is suited for commercial and light industrial fire alarm applications where intelligent addressable control panels are specified. It is used to bring conventional initiating devices into an addressable system architecture, allowing each circuit to report independently to the fire alarm control panel. Typical installations include office buildings, schools, healthcare facilities, and other occupancies requiring addressable detection with multiple supervised input zones.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTwo independent two-wire initiating device circuits (IDCs) at two consecutive addresses\u003c\/li\u003e\n\u003cli\u003eMonitors normally open contact fire alarm and supervisory devices\u003c\/li\u003e\n\u003cli\u003eCompatible with intelligent, two-wire addressable fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eSupports conventional heat detectors, manual pull stations, and two-wire smoke detectors\u003c\/li\u003e\n\u003cli\u003eSingle panel-controlled LED for local status indication\u003c\/li\u003e\n\u003cli\u003eDual-address architecture allows each IDC to report independently to the panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use with intelligent, two-wire addressable fire alarm control panels that accept dual monitor module devices. Consult the fire alarm control panel listing and system design documents to confirm address capacity and module compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. Disconnect power from the fire alarm control panel and verify the signaling line circuit is de-energized before wiring the module. Follow the manufacturer wiring diagram for correct IDC and SLC connections. After installation, perform a full point-to-point test to verify both addresses report correctly to the control panel.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: Dual Addressable Monitor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitiating Device Circuits\u003c\/strong\u003e: 2 independent two-wire IDCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Configuration\u003c\/strong\u003e: Two separate, consecutive addresses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Input Type\u003c\/strong\u003e: Normally open dry-contact devices and two-wire smoke detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e: Single panel-controlled LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003e: Intelligent two-wire addressable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: flt-mdf-300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525490868530,"sku":"FLT-MDF-300","price":209.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/adcb0c21df469ca11159587af9e43dc9.jpg?v=1785475467"},{"product_id":"fire-lite-sd365-addressable-photoelectric-smoke-detector","title":"Fire-lite sd365 Addressable Photoelectric Smoke Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE sd365 is an addressable, plug-in photoelectric smoke detector built for LiteSpeed-compatible fire alarm systems. It uses an enhanced optical sensing chamber engineered to detect smoke from a wide range of combustion sources, meeting more stringent code standards than previous-generation devices. The low-profile, contemporary housing is designed to blend into commercial ceiling environments while maintaining reliable detection performance. Licensed fire alarm technicians and life-safety contractors are the typical installing trades for this device.\u003c\/p\u003e\u003cp\u003eThe sd365 is intended for addressable fire alarm systems running the LiteSpeed protocol. Its intelligent plug-in design simplifies field replacement and reduces installation time on new construction and retrofit projects alike. The detector is suited for commercial and light industrial occupancies where addressable loop architecture is specified by the authority having jurisdiction.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAddressable plug-in design for fast field replacement without rewiring\u003c\/li\u003e\n\u003cli\u003eEnhanced optical sensing chamber detects smoke from a wide range of combustion sources\u003c\/li\u003e\n\u003cli\u003eCompatible with LiteSpeed addressable fire alarm systems only\u003c\/li\u003e\n\u003cli\u003eModern, low-profile housing engineered for aesthetic and functional fit in commercial environments\u003c\/li\u003e\n\u003cli\u003eEngineered to meet more stringent smoke detection code standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for LiteSpeed-compatible addressable fire alarm systems. This detector replaces the SD355.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and local authority having jurisdiction requirements. Power down and isolate the addressable loop before removing or inserting the detector base. Do not install in environments outside the detector's rated operating conditions, and verify address programming matches the panel configuration before returning the system to service.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Technology\u003c\/strong\u003e: Photoelectric optical sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: LiteSpeed addressable only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sd365\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51620983570738,"sku":"SD365","price":92.22,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-chg-120f-battery-charging-system","title":"Fire-lite Alarms by Honeywell CHG-120F Battery Charging System","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL CHG-120F is a remote battery charging system designed to maintain and charge backup batteries in fire alarm control panel installations. This unit serves as a dedicated charging accessory, ensuring that standby battery power remains at the capacity required by life-safety system codes. It is typically installed by licensed fire alarm technicians or low-voltage electricians working on commercial or light-commercial fire detection systems.\u003c\/p\u003e\n\u003cp\u003eThe CHG-120F is used in fire alarm system installations where remote or supplemental battery charging capability is required. It supports configurations where the main control panel cannot handle battery charging on its own, or where code compliance demands a dedicated charging source. Typical installations are found in commercial buildings, multi-tenant facilities, and other occupancies requiring NFPA 72-compliant fire detection systems.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote battery charging function for fire alarm control system backup power\u003c\/li\u003e\n  \u003cli\u003eDesigned as a fire control accessory for life-safety system applications\u003c\/li\u003e\n  \u003cli\u003eSupports standby battery maintenance in NFPA 72-compliant installations\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit for straightforward procurement and replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style fire control accessory for use in compatible fire alarm panel installations requiring remote battery charging support.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage electrician in accordance with NFPA 72 and all applicable local codes. Disconnect and de-energize the fire alarm control panel and isolate the battery circuit before servicing or connecting this unit. Follow the manufacturer wiring documentation for proper connection sequencing. Do not restore power to the system until all connections are verified and the panel has been tested per the authority having jurisdiction.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: CHG-120F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67906187067698,"sku":"CHG-120F","price":4251.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/a245758bd5356b0cd51e9076e1182f36.jpg?v=1791165900"},{"product_id":"fire-lite-alarms-h365r-iv-rate-of-rise-heat-detector","title":"Fire-lite Alarms H365R-IV Rate-of-rise Heat Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL H365R-IV is a rate-of-rise heat detector designed for fixed-temperature and rate-of-rise thermal detection in fire alarm systems. This device monitors ambient temperature changes and triggers an alarm when temperature rises rapidly or exceeds a set threshold, providing early warning in environments where smoke detectors are not suitable. It ships in an ivory finish and is sold as a single unit. Licensed fire alarm technicians and low-voltage contractors install this detector as part of a conventional or addressable fire alarm system.\u003c\/p\u003e\n\u003cp\u003eRate-of-rise heat detectors like the H365R-IV are commonly used in residential and light commercial applications where cooking vapors, dust, or steam would cause nuisance alarms with standard smoke detectors. Typical installation locations include kitchens, garages, utility rooms, and attics. The ivory finish blends with standard ceiling surfaces in residential and commercial construction. This unit is suited for new construction wiring as well as retrofit installations into existing fire alarm circuits.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRate-of-rise thermal detection triggers alarm on rapid temperature increase\u003c\/li\u003e\n  \u003cli\u003eFixed-temperature backup threshold provides redundant detection\u003c\/li\u003e\n  \u003cli\u003eIvory finish suits standard residential and commercial ceiling applications\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit for precise quantity ordering\u003c\/li\u003e\n  \u003cli\u003eDesigned for environments where smoke-based detection is not appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-install thermal detector for conventional fire alarm systems requiring rate-of-rise heat detection devices.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local fire codes. De-energize the fire alarm control panel circuit before making any wiring connections to this detector. Follow the manufacturer wiring diagram and mounting instructions for correct base and detector orientation. Do not install in locations subject to freezing temperatures or outside the detector's rated environmental limits.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection Type\u003c\/strong\u003e: Rate-of-Rise and Fixed Temperature\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\/Finish\u003c\/strong\u003e: Ivory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Thermal Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: H365R-IV\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67906283307314,"sku":"H365R-IV","price":566.54,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-w-mmf-wireless-monitor-module","title":"Fire-lite Alarms by Honeywell W-MMF Wireless Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL W-MMF is a wireless monitor module designed to integrate conventional dry-contact initiating devices into a compatible wireless fire alarm system. The module transmits supervised signals from connected devices  -  such as pull stations, heat detectors, or waterflow switches  -  back to the main fire alarm control panel without the need for hardwired circuit runs between the device and the panel. It is intended for installation by licensed fire alarm technicians in applications where running new wiring is impractical or cost-prohibitive.\u003c\/p\u003e\n\u003cp\u003eThe W-MMF is suited for use in both retrofit and new-construction fire alarm projects where a wireless architecture is specified. Typical applications include commercial buildings, multi-tenant properties, and facilities where structural constraints limit conduit or cable installation. The module provides a supervised wireless link, supporting system integrity monitoring as required by fire alarm standards. It ships as a single unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eWireless signal transmission eliminates the need for dedicated initiating device circuit wiring runs\u003c\/li\u003e\n  \u003cli\u003eMonitors dry-contact initiating devices including pull stations, heat detectors, and waterflow switches\u003c\/li\u003e\n  \u003cli\u003eSupervised wireless communication supports tamper and trouble detection\u003c\/li\u003e\n  \u003cli\u003eDesigned for retrofit and new-construction wireless fire alarm installations\u003c\/li\u003e\n  \u003cli\u003eSingle-unit packaging for straightforward field deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style wireless monitor module for use within compatible FIRE-LITE ALARMS BY HONEYWELL wireless fire alarm systems. Confirm panel and wireless network compatibility with system documentation before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. Disable or isolate the affected fire alarm zone at the control panel before connecting or servicing the module. Verify wireless signal strength and supervision intervals meet the authority having jurisdiction requirements after installation. Do not place the module in locations that exceed its rated environmental limits or that cause RF interference with the wireless network.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: W-MMF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67906689794354,"sku":"W-MMF","price":777.59,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-302-aw-135-heat-detector","title":"Fire-lite Alarms by Honeywell 302-AW-135 Heat Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL 302-AW-135 is a fixed-temperature heat detector rated for 135 degrees F activation, designed for all-weather vertical mount installations. It is built for environments where standard detectors would be exposed to moisture, dust, or temperature extremes that exceed typical indoor ratings. The unit triggers at a set thermal threshold, signaling the fire alarm control panel when ambient heat reaches the rated activation point. Licensed fire alarm technicians and electricians install this device as part of a life-safety detection system in applications where smoke detectors are not suitable.\u003c\/p\u003e\n\u003cp\u003eThis detector is suited for commercial and industrial environments where outdoor or semi-outdoor conditions demand a ruggedized sensing device. Typical installation scenarios include loading docks, covered parking structures, unheated storage areas, and similar locations subject to weather exposure. Its vertical mount orientation suits junction-box mounting on walls or structural members. The 135 degrees F fixed-temperature rating makes it appropriate for spaces that do not experience normal ambient temperatures approaching that threshold during non-fire conditions.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eFixed-temperature detection activates at 135 degrees F\u003c\/li\u003e\n  \u003cli\u003eAll-weather construction rated for exposure to moisture and environmental contaminants\u003c\/li\u003e\n  \u003cli\u003eVertical mount design for wall or structural-member installation\u003c\/li\u003e\n  \u003cli\u003eExplosion-proof detector category suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit (each)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation heat detector for fire alarm systems requiring a fixed-temperature, all-weather vertical-mount sensing device at the 135 degrees F threshold.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or qualified electrician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel circuit before wiring the detector, and follow the control panel manufacturer's wiring and end-of-line resistor requirements. Explosion-proof applications may require conduit sealing fittings per NEC Article 501. Do not apply power to the circuit until all connections are inspected and the enclosure is properly secured.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActivation Temperature\u003c\/strong\u003e: 135 degrees F (fixed)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMount Orientation\u003c\/strong\u003e: Vertical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e: All-weather\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetector Category\u003c\/strong\u003e: Explosion Proof\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 302-AW-135\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67906960654642,"sku":"302-AW-135","price":257.07,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bb-6f-floor-mount-cabinet-6-module","title":"Fire-lite Alarms by Honeywell BB-6F Floor Mount Cabinet 6 Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BB-6F is a floor-mounting cabinet designed to house up to six mult modules in a fire alarm control system. The cabinet provides a dedicated enclosure for organizing and protecting fire control accessory modules, keeping wiring and components secure in commercial and light industrial installations. Licensed fire alarm technicians and low-voltage contractors install this cabinet as part of a larger fire detection and notification system build-out. Its capacity for up to six modules makes it well suited for mid-size panel expansions where multiple input, output, or relay modules must be physically co-located and protected.\u003c\/p\u003e\n\u003cp\u003eThis cabinet is intended for floor-mounted installations in fire alarm system environments. It is used where panel expansions require additional module housing beyond what a primary control enclosure can accommodate. Typical applications include commercial buildings, institutional facilities, and industrial sites where fire alarm systems require modular expansion. Fire alarm installers integrate this cabinet into new system installations or retrofit projects that need additional module capacity without replacing the primary control panel.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eFloor-mounting design for stable, freestanding installation in equipment rooms or corridors\u003c\/li\u003e\n  \u003cli\u003eHouses up to six mult modules, supporting mid-scale fire alarm system expansion\u003c\/li\u003e\n  \u003cli\u003eDedicated enclosure keeps fire control accessory modules organized and protected\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit, compatible with Fire-Lite Alarms modular system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style enclosure for use with FIRE-LITE ALARMS BY HONEYWELL fire control accessory modules in floor-mounted fire alarm system configurations.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local fire codes. De-energize the fire alarm control panel and any associated power supplies before making connections inside the cabinet. Verify that all module wiring is routed and secured per the system manufacturer documentation and local authority having jurisdiction requirements. Do not install this cabinet in locations subject to moisture, excessive heat, or physical damage without appropriate environmental protection.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Capacity\u003c\/strong\u003e: Up to 6 modules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Floor mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BB-6F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67907147989298,"sku":"BB-6F","price":1177.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/e7b127a68e2ea04eb950dcb6759d2dcd.jpg?v=1791174978"},{"product_id":"fire-lite-alarms-b200sr-lf-wh-low-frequency-sounder-base","title":"Fire-lite Alarms B200SR-LF-WH Low Frequency Sounder Base","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL B200SR-LF-WH is a low frequency sounder base designed for use in commercial and residential fire alarm systems. This detection accessory mounts beneath compatible smoke detector heads and produces a low frequency audible alarm tone, which is particularly effective at waking sleeping occupants and meeting code requirements for sleeping areas. Licensed fire alarm technicians and low-voltage electricians install this device as part of addressable or conventional detection systems. The white finish suits standard ceiling and wall installations where a neutral appearance is required.\u003c\/p\u003e\n\u003cp\u003eThe B200SR-LF-WH is used in fire alarm installations where low frequency sounder capability is required at the detector mounting point. This is common in sleeping areas of hotels, dormitories, assisted living facilities, and residential occupancies where NFPA 72 mandates low frequency 520 Hz signaling for occupant notification. The sounder base integrates directly with compatible detector heads, eliminating the need for a separate notification appliance at each detection point.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eLow frequency sounder output suited for sleeping area notification compliance\u003c\/li\u003e\n  \u003cli\u003eBase-mount design integrates with compatible detector heads for a compact installation footprint\u003c\/li\u003e\n  \u003cli\u003eWhite finish for clean, unobtrusive ceiling or wall appearance\u003c\/li\u003e\n  \u003cli\u003eSold individually, allowing installation on a per-point basis\u003c\/li\u003e\n  \u003cli\u003eClassified as a detection accessory for fire alarm system applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style detection accessory sounder base for use with compatible FIRE-LITE ALARMS BY HONEYWELL detector heads in fire alarm system applications. Consult the manufacturer installation documentation to confirm compatible detector models before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage electrician in accordance with NFPA 72 and all applicable local codes. Disable and lock out the fire alarm control panel circuit before connecting or removing the sounder base. Verify detector head compatibility with this base before mounting. After installation, conduct a full system functional test per the authority having jurisdiction requirements.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Low Frequency Sounder Base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: White\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Detection Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: B200SR-LF-WH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67907291545906,"sku":"B200SR-LF-WH","price":323.82,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bg-12l-pull-station","title":"Fire-lite Alarms by Honeywell BG-12L Pull Station","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BG-12L is a dual-action manual pull station with a key lock mechanism, designed for use in commercial and institutional fire alarm systems. Dual-action operation requires two deliberate physical steps to trigger the alarm, reducing the risk of accidental activation. The key lock allows authorized personnel to reset and service the station after activation without removing the unit from the wall. Licensed fire alarm technicians and life safety contractors are the primary installers of this device.\u003c\/p\u003e\u003cp\u003eThe BG-12L is suited for commercial buildings, schools, healthcare facilities, and other occupancies requiring manual fire alarm initiating devices. It mounts at standard pull station height per applicable codes and integrates with conventional or addressable fire alarm control panels where compatible initiating device circuits are present. Its dual-action design meets common code requirements for manual stations in high-traffic or vandalism-prone environments.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDual-action pull mechanism reduces risk of accidental or malicious false alarms\u003c\/li\u003e\n\u003cli\u003eKey lock allows authorized reset and servicing without full removal from the wall\u003c\/li\u003e\n\u003cli\u003eDesigned for wall-mount installation at code-required heights in commercial occupancies\u003c\/li\u003e\n\u003cli\u003eSold as a single unit for straightforward replacement or new installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style manual pull station for use in commercial fire alarm systems requiring a dual-action initiating device with key lock reset capability.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. Disconnect and lock out the fire alarm control panel circuit before wiring or replacing the device. Mount at the height specified by NFPA 72 and the authority having jurisdiction. After installation, perform a functional test per system commissioning requirements before returning the system to service.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Pull Stations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BG-12L\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67907323167026,"sku":"BG-12L","price":128.64,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-pwrmod24-nac-power-booster","title":"Fire-lite Alarms by Honeywell PWRMOD24 Nac Power Booster","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL PWRMOD24 is a 3-amp NAC power booster module designed to expand the notification appliance circuit capacity of fire alarm control panels. NAC booster modules supplement the output current available to notification appliances such as horns, strobes, and horn-strobe combinations when the base panel cannot supply sufficient current on its own. This module is installed by licensed fire alarm technicians as part of a compliant fire alarm system layout. At 3 amps of output current, it provides meaningful additional drive capacity for larger or more complex notification zones.\u003c\/p\u003e\n\u003cp\u003eThe PWRMOD24 is suited for commercial and light industrial fire alarm installations where notification appliance circuits require supplemental power beyond what the primary fire alarm control panel delivers. Typical applications include multi-zone systems, expanded floor layouts, or retrofits where additional notification appliances have been added to an existing system. It is categorized under fire surge protection components and is sold as an individual unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e3-amp NAC output current for supplemental notification appliance circuit power\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate with fire alarm control panels requiring additional NAC capacity\u003c\/li\u003e\n  \u003cli\u003eSupports horns, strobes, and combination horn-strobe notification appliances\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit for straightforward procurement and replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style NAC power booster for use with compatible fire alarm control panel systems requiring supplemental notification appliance circuit current. No specific compatible panel models were provided in the available product data.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and follow lockout-tagout procedures before making any wiring connections. Verify that the total NAC load does not exceed the rated output of the booster module. All wiring methods and circuit supervision must comply with the authority having jurisdiction requirements.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e: 3 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Surge Protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: PWRMOD24\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67908546593074,"sku":"PWRMOD24","price":483.76,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bg12tr-trim-ring-assembly","title":"Fire-lite Alarms by Honeywell BG12TR Trim Ring Assembly","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BG12TR is a trim ring assembly designed for use with the BG12 series manual pull station. This component provides a finished, professional appearance around the pull station faceplate where surface-mounted installations require a clean transition between the device and the wall or backbox. Fire alarm system installers and low-voltage contractors install this part during new construction or retrofit projects to complete the pull station assembly. The trim ring is sold as an individual unit and is a direct accessory for the BG12 pull station line.\u003c\/p\u003e\u003cp\u003eThis trim ring assembly is suited for commercial and institutional fire alarm installations where BG12 series manual pull stations are deployed. Typical applications include offices, schools, healthcare facilities, and other occupancies requiring manual fire alarm initiation devices. It is used when the installation conditions call for a surface-mount configuration that benefits from a trim ring to cover gaps or rough wall edges around the pull station mounting location.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDesigned specifically for the BG12 series manual pull station\u003c\/li\u003e\n\u003cli\u003eProvides a clean, finished appearance in surface-mount installations\u003c\/li\u003e\n\u003cli\u003eSold individually as a single unit replacement or add-on accessory\u003c\/li\u003e\n\u003cli\u003eCompatible with standard fire alarm pull station backbox configurations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style accessory trim ring for use with the BG12 series manual pull station fire alarm devices.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel notification appliance circuit or place the panel in test mode before servicing any pull station components. Ensure the backbox is properly secured before attaching the trim ring. Verify that the trim ring seats flush against the wall surface before completing the installation.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BG12TR\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67909231182130,"sku":"BG12TR","price":85.55,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-chs-6-fire-control-chassis","title":"Fire-lite Alarms by Honeywell CHS-6 Fire Control Chassis","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL CHS-6 is a fire control chassis designed to fit into the BB-6 cabinet enclosure. It serves as the structural mounting framework for fire alarm control components, providing the internal support structure required to house and secure control electronics within the BB-6 cabinet assembly. This chassis is a fire control accessory sold as an individual unit and is installed by licensed fire alarm technicians during system build-out, expansion, or service replacement work.\u003c\/p\u003e\u003cp\u003eThe CHS-6 is intended for use in fire alarm control panel installations where the BB-6 cabinet is specified. It is suited for commercial and light industrial fire detection and notification system applications. Installers integrating or servicing FIRE-LITE ALARMS BY HONEYWELL fire alarm systems will find this chassis is the correct internal mounting component to pair with the BB-6 enclosure.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDesigned to fit directly into the BB-6 cabinet enclosure\u003c\/li\u003e\n\u003cli\u003eProvides internal structural support for fire alarm control electronics\u003c\/li\u003e\n\u003cli\u003eSold as a single unit for targeted replacement or new installation use\u003c\/li\u003e\n\u003cli\u003eFire control accessory category component for FIRE-LITE ALARMS BY HONEYWELL systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eThe CHS-6 chassis is designed to fit into the BB-6 cabinet enclosure as specified by the manufacturer.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and applicable local fire codes. De-energize the fire alarm control panel and follow lockout\/tagout procedures before servicing or replacing internal chassis components. Verify proper seating and secure mounting of the chassis within the BB-6 cabinet before restoring power and conducting a full system functional test.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: CHS-6\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67910031671602,"sku":"CHS-6","price":220.54,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-b200s-lf-wh-sounder-base","title":"Fire-lite Alarms by Honeywell B200S-LF-WH Sounder Base","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL B200S-LF-WH is a low frequency addressable sounder base designed for use in fire alarm notification systems. It mounts beneath compatible addressable smoke or heat detector heads and provides an integrated audible alert directly at the device location. Low frequency output is intended for applications where code or building design requires tones below the standard 3 kHz range, such as sleeping areas covered under NFPA 72 requirements. This base is finished in white to blend with standard ceiling installations. Licensed fire alarm technicians and system integrators are the primary installers for this type of device.\u003c\/p\u003e\n\u003cp\u003eThe B200S-LF-WH is suited for addressable fire alarm systems in residential and commercial occupancies where low frequency sounder bases are required at detector locations. Typical installations include dormitories, hotel guest rooms, apartment buildings, and assisted living facilities where NFPA 72 mandates low frequency signaling in sleeping areas. It serves as a notification accessory within a larger addressable loop, reducing the need for separate wall-mounted horn or sounder devices at each detector point.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eLow frequency audible output suitable for sleeping area notification compliance\u003c\/li\u003e\n  \u003cli\u003eAddressable design integrates directly into addressable fire alarm control panel loops\u003c\/li\u003e\n  \u003cli\u003eSounder base eliminates the need for a separate notification appliance at the detector location\u003c\/li\u003e\n  \u003cli\u003eWhite finish for standard ceiling aesthetics\u003c\/li\u003e\n  \u003cli\u003eSold individually as a single unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style notification accessory for use with compatible addressable detector heads in low frequency fire alarm sounder base applications. Consult the FIRE-LITE ALARMS BY HONEYWELL installation documentation to confirm compatible detector head models before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize and isolate the affected addressable loop at the fire alarm control panel before removing or installing any device on the loop. Do not force the detector head onto the base; follow the manufacturer torque and alignment guidance in the product installation sheet. After installation, perform a full functional test of the sounder base and verify proper address programming at the control panel.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Low Frequency Audible\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDevice Type\u003c\/strong\u003e: Addressable Sounder Base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: White\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Notification Accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: B200S-LF-WH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67910766952754,"sku":"B200S-LF-WH","price":424.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/c58878a2f2db11ad8a0e7b5410957210.jpg?v=1791200165"},{"product_id":"fire-lite-alarms-by-honeywell-w-h355-wireless-heat-detector","title":"Fire-lite Alarms by Honeywell W-H355 Wireless Heat Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL W-H355 is a wireless fixed heat detector designed for use in fire alarm systems where smoke-based detection is not suitable. Fixed heat detectors activate when ambient temperature reaches a predetermined threshold, making them appropriate for environments such as dusty utility spaces, kitchens, and garages where smoke detectors would generate nuisance alarms. The W-H355 communicates wirelessly, eliminating the need to run dedicated detection wiring to the device location. Licensed fire alarm technicians and system integrators are the primary installers of this device.\u003c\/p\u003e\u003cp\u003eThe W-H355 is suited for residential and light commercial applications where a wired heat detector installation is impractical or cost-prohibitive. It integrates into compatible FIRE-LITE ALARMS BY HONEYWELL wireless fire alarm panel ecosystems. Typical installation scenarios include retrofit projects in existing structures where open-ceiling wiring is not feasible, as well as new construction where wireless system architecture has been specified by the engineer of record.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eWireless design eliminates the need for dedicated detection circuit wiring\u003c\/li\u003e\n\u003cli\u003eFixed heat detection responds when temperature reaches a set threshold\u003c\/li\u003e\n\u003cli\u003eSuitable for environments where smoke detection is prone to nuisance alarms\u003c\/li\u003e\n\u003cli\u003eSold as a single unit (each)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use within compatible FIRE-LITE ALARMS BY HONEYWELL wireless fire alarm panel systems. Consult the panel documentation and the W-H355 installation guide to confirm specific panel compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize and lock out the fire alarm control panel before adding or removing any system devices. Verify wireless signal strength and device registration with the control panel after installation. Do not install in locations that exceed the rated environmental parameters specified in the product documentation.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Type\u003c\/strong\u003e: Fixed Heat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e: Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: W-H355\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67911252705586,"sku":"W-H355","price":709.47,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-dp-es-r-dress-panel-evolution-red","title":"Fire-lite Alarms by Honeywell DP-ES-R Dress Panel Evolution Red","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL DP-ES-R is a dress panel designed for the Evolution series fire alarm control system. Dress panels provide the finished exterior enclosure face that covers the internal control board assembly, giving the installation a clean, professional appearance. This red-colored panel is a fire control accessory sold as an individual unit and is installed by licensed fire alarm technicians during new installations or when replacing a damaged or worn exterior panel on an existing Evolution series cabinet.\u003c\/p\u003e\n\u003cp\u003eThis dress panel is intended for use with Evolution series fire alarm control panels in commercial fire alarm applications. It serves as the front-facing cosmetic and structural cover for the control panel enclosure. Installations are typically found in commercial buildings, light industrial facilities, and similar occupancies where Evolution series fire alarm systems are deployed. The red finish is consistent with standard fire alarm equipment identification requirements.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRed finish for standard fire alarm equipment identification\u003c\/li\u003e\n  \u003cli\u003eDesigned for Evolution series fire alarm control panel enclosures\u003c\/li\u003e\n  \u003cli\u003eOEM-style replacement or new installation dress panel\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new installation dress panel for Evolution series fire alarm control panel enclosures by FIRE-LITE ALARMS BY HONEYWELL.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation and replacement of fire alarm control panel components should be performed by a licensed fire alarm technician in accordance with NFPA 72 and applicable local codes. De-energize and fully power down the fire alarm control panel before removing or installing any enclosure panels. Verify the dress panel model is correct for the specific Evolution series cabinet variant before installation. Coordinate with the authority having jurisdiction if the panel is in an active monitored system before taking it offline for service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: Red\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: Evolution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: DP-ES-R\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67912011481394,"sku":"DP-ES-R","price":436.81,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-ecc-50-100-emergency-command-center","title":"Fire-lite Alarms ECC-50\/100 Emergency Command Center","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL ECC-50\/100 is a voice evacuation emergency command center designed for fire alarm and life safety systems. It provides amplified audio output for emergency notification, enabling clear voice messaging and tone signals throughout a protected facility. The unit is rated at 50 watts of output power, making it suitable for mid-size installations requiring reliable, intelligible emergency communications. Licensed fire alarm technicians and low-voltage contractors are the primary installers of this equipment.\u003c\/p\u003e\u003cp\u003eThe ECC-50\/100 is applied in voice evacuation fire alarm systems, typically in commercial, institutional, or multi-story residential buildings where code-mandated voice notification is required. It serves as the central audio control point for distributing emergency and evacuation messages to speaker circuits throughout the building. Installations commonly follow NFPA 72 requirements for emergency communications systems.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e50-watt amplified output for voice evacuation and emergency tone signaling\u003c\/li\u003e\n\u003cli\u003eDesigned for integration into fire alarm and life safety system architectures\u003c\/li\u003e\n\u003cli\u003eSupports voice messaging and coded tone distribution to speaker circuits\u003c\/li\u003e\n\u003cli\u003eSold as an individual unit (each)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style component for use in voice evacuation fire alarm systems. No specific compatible model numbers or system families were provided in the available product data.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. Disconnect and lock out all power to the fire alarm control panel before servicing or wiring any components. Follow the manufacturer's wiring diagrams precisely and verify proper grounding before restoring power. A full system functional test is required after installation to confirm voice and tone output on all connected speaker circuits.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power\u003c\/strong\u003e: 50 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Voice Evacuation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ECC-50\/100\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67913280520498,"sku":"ECC-50\/100","price":7901.16,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-b300-6-6-inch-detector-base","title":"Fire-lite Alarms by Honeywell B300-6 6 Inch Detector Base","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL B300-6 is a 6-inch detector mounting base finished in white, designed for use in fire detection systems. This base provides a secure, standardized mounting point for compatible smoke or heat detectors, allowing for clean installation on standard junction boxes or ceiling surfaces. It is a detection accessory typically installed by licensed fire alarm technicians or electrical contractors during new construction or system upgrade projects. The white finish blends with standard ceiling surfaces for a professional appearance in commercial and residential fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eThe B300-6 is intended for use in fire alarm detection system installations where a 6-inch base is required. It suits commercial buildings, office spaces, schools, healthcare facilities, and residential structures requiring code-compliant detector mounting. This base is sold individually and is appropriate for projects requiring a single replacement or small-quantity installation alongside compatible Fire-Lite detection devices.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e6-inch base diameter for standard detector mounting applications\u003c\/li\u003e\n  \u003cli\u003eWhite finish suitable for typical ceiling and wall surfaces\u003c\/li\u003e\n  \u003cli\u003eDetection accessory category  -  designed for fire alarm system use\u003c\/li\u003e\n  \u003cli\u003eSold individually (quantity of one per unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style mounting base for use within compatible fire detection systems. Consult the Fire-Lite Alarms product documentation to confirm detector head compatibility before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or qualified electrical contractor in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel circuit before connecting or disconnecting any detector base wiring. Verify junction box size and mounting hole pattern are compatible with the B300-6 before final installation. Do not energize the system until all wiring connections are inspected and the detector head is properly seated in the base.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Diameter\u003c\/strong\u003e: 6 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: White\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Detection Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: B300-6\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67914112008498,"sku":"B300-6","price":79.82,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bat-1270-bp-12v-7-0ah-battery","title":"Fire-lite Alarms by Honeywell BAT-1270-BP 12V 7.0ah Battery","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BAT-1270-BP is a sealed lead acid backup battery rated at 12 volts and 7.0 amp-hours (Ah), packaged in a bulk pack of 5 units. It is designed to provide standby power to fire alarm control panels and related life-safety equipment during primary power interruptions. This battery is a standard replacement component used in commercial and residential fire alarm systems. Licensed fire alarm technicians and licensed electricians are the typical installers for this type of battery in life-safety applications.\u003c\/p\u003e\n\u003cp\u003eThis battery is suited for use in fire alarm control panels, annunciators, and other low-voltage fire power accessory applications where a 12-volt sealed lead acid backup source is required. The bulk pack of 5 pieces is intended for contractors and service companies that maintain multiple panels or perform scheduled battery replacements across several installations. It falls under the fire power accessories category and is sold per each unit within the pack.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e12-volt, 7.0 Ah sealed lead acid chemistry for reliable standby power\u003c\/li\u003e\n  \u003cli\u003eBulk pack of 5 units supports multi-panel service calls and scheduled maintenance contracts\u003c\/li\u003e\n  \u003cli\u003eSealed construction requires no electrolyte maintenance\u003c\/li\u003e\n  \u003cli\u003eFire power accessory category  -  suitable for life-safety panel backup applications\u003c\/li\u003e\n  \u003cli\u003eStandard form factor commonly used in commercial fire alarm control equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement battery for fire alarm control panels and life-safety systems requiring a 12-volt, 7.0 Ah sealed lead acid backup power source.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or qualified electrician in accordance with NFPA 72 and applicable local codes. Disconnect AC power and disable the panel before replacing the battery to avoid false alarms or system faults. Observe correct polarity when connecting the battery leads, and verify the replacement battery meets the panel manufacturer's specified voltage and capacity requirements. Dispose of spent lead acid batteries in compliance with local environmental regulations.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 12 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity\u003c\/strong\u003e: 7.0 Ah\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Type\u003c\/strong\u003e: Sealed Lead Acid\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePack Quantity\u003c\/strong\u003e: 5 pieces\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Power Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BAT-1270-BP\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67915176902962,"sku":"BAT-1270-BP","price":1074.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/6331d7ceeef096acc69b457c03c4d8a2.jpg?v=1791252564"},{"product_id":"fire-lite-alarms-by-honeywell-mdf-300-dual-monitor-module","title":"Fire-lite Alarms by Honeywell MDF-300 Dual Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL MDF-300 is an addressable dual monitor module designed for use in fire alarm control systems. It monitors two separate supervised circuits, allowing a fire alarm panel to detect open or short conditions on connected initiating device circuits. The MDF-300 communicates its status back to the main control panel over an addressable loop, giving system technicians precise fault and alarm location data. Licensed fire alarm contractors and low-voltage technicians are the primary installers of this device.\u003c\/p\u003e\n\u003cp\u003eThe MDF-300 is used in commercial and institutional fire alarm installations where dual-circuit monitoring is required at a single addressable address. It is suited for retrofit and new-construction projects where panel loop capacity and wiring economy matter. The module fits within fire alarm control panel accessory applications and is categorized as a fire control accessory sold as an individual unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eAddressable dual monitor function provides two supervised circuit inputs from a single loop address\u003c\/li\u003e\n  \u003cli\u003eDesigned for integration with addressable fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eSupports detection of open and short fault conditions on monitored circuits\u003c\/li\u003e\n  \u003cli\u003eSold as an individual unit for flexible system expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style addressable module for use with compatible FIRE-LITE ALARMS BY HONEYWELL addressable fire alarm control panel systems. Verify panel loop protocol compatibility before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm contractor or qualified low-voltage technician in accordance with NFPA 72 and all applicable local codes. Power down and isolate the addressable loop before connecting or removing the module. Follow the panel manufacturer documentation for address programming and end-of-line resistor requirements. Do not install in environments outside the module rated operating conditions.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MDF-300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67916201853234,"sku":"MDF-300","price":421.94,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-h365ht-heat-detector","title":"Fire-lite Alarms by Honeywell H365HT Heat Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL H365HT is a high-temperature heat detector designed for fixed-temperature thermal detection in fire alarm systems. It responds to elevated ambient temperatures that exceed the detector's set threshold, triggering an alarm signal to the connected fire alarm control panel. Thermal detectors of this type are well suited for environments where smoke detectors would produce nuisance alarms, such as areas with dust, steam, or combustion byproducts. Installation is typically performed by licensed fire alarm technicians or low-voltage contractors working under applicable local and national fire codes.\u003c\/p\u003e\n\u003cp\u003eThe H365HT is a thermal detector unit sold individually. It is intended for use in commercial and light industrial fire alarm installations where high-temperature rated detection is required. Typical applications include mechanical rooms, kitchens, laundry areas, garages, and other spaces subject to elevated ambient temperatures where a standard-rate heat or smoke detector would not be appropriate. The detector integrates into conventional or compatible addressable fire alarm systems as part of a broader life-safety network.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-temperature fixed-threshold thermal detection for challenging environments\u003c\/li\u003e\n  \u003cli\u003eDesigned to minimize nuisance alarms in dusty, steamy, or high-heat areas\u003c\/li\u003e\n  \u003cli\u003eCompact detector form factor for straightforward ceiling or wall mounting\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit for targeted replacement or new installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation thermal detector for compatible fire alarm control panels and initiating device circuits requiring a high-temperature heat detector.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and applicable local codes. Disconnect and lock out power to the fire alarm control panel and the initiating device circuit before removing or connecting any detector. Follow the control panel manufacturer's wiring and zone configuration instructions. Do not bypass or short any initiating device circuit terminals during service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Thermal Detectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: H365HT\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67916296716594,"sku":"H365HT","price":339.29,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-sd365t-photo-thermal-detector","title":"Fire-lite Alarms by Honeywell SD365T Photo Thermal Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL SD365T is a multicriteria fire detector combining photoelectric smoke sensing with thermal detection in a single unit. This type of detector uses scattered-light technology to identify slow-smoldering fires while the integrated thermal element responds to rapid temperature rise, reducing nuisance alarms and improving detection accuracy. It is designed for installation on compatible fire alarm control panels in commercial and light commercial life-safety systems. Licensed fire alarm technicians and low-voltage contractors are the primary installers of this device.\u003c\/p\u003e\u003cp\u003eThe SD365T is suited for commercial occupancies where code requires multicriteria detection, including offices, hotels, schools, and healthcare facilities. Its combination sensing approach addresses environments where either smoke-only or heat-only detectors may produce false activations or miss early fire signatures. Where local Authority Having Jurisdiction requires compliance with NFPA 72, this detector type is a common solution for challenging detection zones.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eCombines photoelectric smoke detection with thermal sensing in one head\u003c\/li\u003e\n\u003cli\u003eMulticriteria detection logic reduces nuisance alarm rates\u003c\/li\u003e\n\u003cli\u003eSingle unit replaces separate smoke and heat detector installations\u003c\/li\u003e\n\u003cli\u003eSold individually (unit of measure: each)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style replacement or new-installation detector for use with compatible FIRE-LITE ALARMS BY HONEYWELL fire alarm control panels and initiating device circuits. Consult the panel compatibility documentation to confirm supported detector addresses and wiring configurations.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. De-energize the initiating device circuit at the fire alarm control panel before mounting or removing any detector head. Follow the control panel installation manual for proper address programming and end-of-line resistor placement. Do not substitute field-fabricated wiring for listed components.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Multicriteria Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SD365T\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67916747276594,"sku":"SD365T","price":358.12,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bb-26-battery-back-box","title":"Fire-lite Alarms by Honeywell BB-26 Battery Back Box","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BB-26 is a battery back box designed to house standby batteries for compatible fire alarm control panels. It provides a dedicated, code-compliant enclosure that keeps backup power components organized and protected within a fire alarm system installation. The BB-26 is a fire control accessory sold as a single unit and is typically installed by licensed fire alarm technicians as part of a complete fire alarm system setup.\u003c\/p\u003e\n\u003cp\u003eThe BB-26 is used in commercial and residential fire alarm applications where a separate battery enclosure is required to meet installation or code requirements. It is designed to mount alongside or near a fire alarm control panel, keeping standby batteries secured and accessible for inspection and service. This type of accessory is standard in installations where the primary control panel enclosure does not have sufficient internal space for backup batteries.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDedicated enclosure for standby backup batteries used in fire alarm systems\u003c\/li\u003e\n  \u003cli\u003eDesigned as a fire control accessory for use with compatible fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eSingle-unit configuration for straightforward installation alongside a control panel\u003c\/li\u003e\n  \u003cli\u003eSupports code-compliant battery backup arrangements in fire alarm system installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style accessory for use with compatible FIRE-LITE ALARMS BY HONEYWELL fire alarm control panels that require an external battery enclosure.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. Disconnect and lock out power to the fire alarm control panel before connecting or servicing battery components. Follow the control panel manufacturer's documentation for proper battery wiring and enclosure mounting procedures. Do not energize the system until all connections have been verified and inspected.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BB-26\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67917325828402,"sku":"BB-26","price":591.33,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-mmf-302-monitor-module","title":"Fire-lite Alarms by Honeywell MMF-302 Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL MMF-302 is an addressable 2-wire monitor module designed for use in fire alarm control systems. It provides supervised monitoring of conventional 2-wire initiating device circuits, allowing a fire alarm panel to receive status signals from connected devices. The MMF-302 integrates into addressable loop wiring, enabling precise point identification within a fire alarm network. Licensed fire alarm technicians and low-voltage electricians are the primary installers of this module in both new construction and retrofit fire alarm projects.\u003c\/p\u003e\n\u003cp\u003eThe MMF-302 is used in commercial and institutional fire alarm installations where conventional initiating devices must be connected to an addressable signaling line circuit. Typical applications include monitoring pull stations, heat detectors, and other 2-wire initiating devices that feed into an addressable fire alarm control panel. It is suited for installations requiring zone-level monitoring with addressable point resolution in facilities such as office buildings, schools, and healthcare environments.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eAddressable design allows individual point identification on a signaling line circuit\u003c\/li\u003e\n  \u003cli\u003eMonitors conventional 2-wire initiating device circuits for supervisory and alarm conditions\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit, suitable for single-zone or multi-zone installations\u003c\/li\u003e\n  \u003cli\u003eDesigned as a fire control accessory for integration with compatible fire alarm control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style addressable monitor module for use with compatible FIRE-LITE ALARMS BY HONEYWELL addressable fire alarm control panels and signaling line circuits. Consult the fire alarm control panel documentation to confirm loop compatibility before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or qualified low-voltage electrician in accordance with NFPA 72 and all applicable local codes. De-energize and isolate the signaling line circuit before connecting or removing the module. Follow the manufacturer wiring diagrams for proper supervisory end-of-line resistor placement on the initiating device circuit. After installation, perform a full point-level functional test to confirm proper addressing and alarm response at the panel.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: Addressable 2-Wire Monitor Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MMF-302\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67917732348210,"sku":"MMF-302","price":416.5,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-ecc-ce6-circuit-expander-module","title":"Fire-lite Alarms by Honeywell ECC-CE6 Circuit Expander Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL ECC-CE6 is a circuit expander module designed to extend the capacity of compatible fire alarm control systems. It adds supplemental circuit outputs to a fire alarm panel, allowing installers to connect additional notification appliances, initiating devices, or control functions beyond the base panel's native capacity. Fire alarm technicians and licensed life-safety contractors are the primary installers of this type of module. It is sold as a single unit and is classified as a fire control accessory.\u003c\/p\u003e\n\u003cp\u003eThe ECC-CE6 is intended for use in commercial and institutional fire alarm installations where base panel circuit capacity must be expanded to meet the demands of larger or more complex protected premises. Typical applications include multi-zone commercial buildings, schools, healthcare facilities, and other occupancies requiring distributed fire alarm notification or detection coverage. Installation is performed during new system commissioning or as part of a system expansion project.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eExpands circuit capacity of compatible fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eSupports additional notification appliance or initiating device circuits\u003c\/li\u003e\n  \u003cli\u003eClassified as a fire control accessory for life-safety system integration\u003c\/li\u003e\n  \u003cli\u003eSold individually as a single unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style circuit expander accessory for compatible FIRE-LITE ALARMS BY HONEYWELL fire alarm control panels and systems. Consult the panel's installation documentation to confirm circuit expander support before ordering.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. The fire alarm control panel must be powered down and the system placed out of service following proper authority having jurisdiction (AHJ) notification procedures before any module is installed or removed. Do not perform wiring work on an energized panel. After installation, a full system functional test is required before returning the system to service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ECC-CE6\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918190510386,"sku":"ECC-CE6","price":1461.14,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-4xtmf-reverse-polarity-module","title":"Fire-lite Alarms by Honeywell 4XTMF Reverse Polarity Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL 4XTMF is a reverse polarity module designed for use in fire alarm and life safety control systems. This accessory monitors or switches polarity on a supervised circuit, allowing the fire alarm control panel to trigger compatible notification or ancillary devices that require a polarity reversal signal. It is a single-unit component sold individually and is typically installed by licensed fire alarm technicians during new system installation or system upgrades.\u003c\/p\u003e\n\u003cp\u003eThe 4XTMF is used as a fire control accessory in commercial and residential fire alarm systems where reverse polarity signaling is required. It integrates into the fire alarm control panel wiring to extend or relay polarity-based control signals to compatible devices downstream. This module is well suited for retrofit applications where existing equipment requires a polarity-switching interface to communicate with newer control panels.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides reverse polarity switching for fire alarm control circuit applications\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit for straightforward inventory and installation management\u003c\/li\u003e\n  \u003cli\u003eDesigned as a fire control accessory compatible with supervised alarm circuits\u003c\/li\u003e\n  \u003cli\u003eCompact module form factor suited for panel or enclosure mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style fire control accessory for use in supervised fire alarm panel circuits requiring reverse polarity signal switching.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize and isolate the fire alarm control panel before making any wiring connections to this module. Verify polarity and circuit supervision requirements from the panel documentation before wiring. Do not restore system power until all connections are confirmed and the panel has been tested per manufacturer guidelines.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 4XTMF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918367359282,"sku":"4XTMF","price":402.54,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-osi-r-ss-beam-detector","title":"Fire-lite Alarms by Honeywell OSI-R-SS Beam Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL OSI-R-SS is a conventional beam detector designed for smoke detection across open or large-area spaces. Beam detectors work by projecting an infrared beam between a transmitter and receiver  -  when smoke interrupts or attenuates the beam, the unit triggers an alarm signal on the conventional detection circuit. This style of detector is well-suited for applications where point-type detectors are impractical due to ceiling height, airflow patterns, or architectural constraints. Installation and commissioning are typically performed by licensed fire alarm technicians familiar with conventional panel wiring and detector alignment procedures.\u003c\/p\u003e\n\u003cp\u003eConventional beam detectors like the OSI-R-SS are commonly deployed in warehouses, atriums, gymnasiums, auditoriums, aircraft hangars, and other large open-volume structures where ceiling heights make spot-type smoke detection difficult or cost-prohibitive. The unit connects to a conventional fire alarm control panel zone and is sold individually as a single unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eConventional beam-style smoke detection suitable for large open-area installations\u003c\/li\u003e\n  \u003cli\u003eInfrared beam attenuation detection principle for reliable smoke sensing across wide spans\u003c\/li\u003e\n  \u003cli\u003eDesigned for integration with conventional fire alarm control panel zones\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit (each)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation component for conventional fire alarm systems using duct and beam detector circuits.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel zone before wiring the detector. Precise optical alignment between the transmitter and receiver is critical for proper operation  -  follow the manufacturer alignment procedure before final commissioning. Do not obstruct the beam path with structural elements, equipment, or HVAC supply diffusers.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Duct\/Beam Detectors and Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: OSI-R-SS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918488437042,"sku":"OSI-R-SS","price":2976.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/ee7a11daaf66cb3e263a2185da8cfb12.jpg?v=1791270321"},{"product_id":"fire-lite-alarms-by-honeywell-4xzmf-zone-function-relay-module","title":"Fire-lite Alarms by Honeywell 4XZMF Zone Function Relay Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL 4XZMF is a zone and function relay module designed for use in fire alarm control systems. It provides a relay output that can be mapped to a specific zone or system function, allowing the fire alarm panel to trigger auxiliary devices or control sequences in response to alarm, supervisory, or trouble conditions. Licensed fire alarm technicians and system integrators typically install and configure this module as part of a listed fire alarm system installation.\u003c\/p\u003e\n\u003cp\u003eThe 4XZMF is suited for commercial and light industrial fire alarm applications where zone-level relay outputs are needed to interface with external equipment such as door holders, HVAC shutdown systems, elevator recall circuits, or notification appliance circuits. It is categorized as a fire control accessory and is sold as a single unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRelay output configurable for zone or system function assignments\u003c\/li\u003e\n  \u003cli\u003eDesigned for integration with compatible fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eSupports auxiliary device control including HVAC shutdown and door holder release\u003c\/li\u003e\n  \u003cli\u003eSold as a single module unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or expansion module for compatible fire alarm control panel systems. No specific panel model numbers were provided in the product data; verify compatibility with the fire alarm control panel documentation before ordering.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and follow lockout\/tagout procedures before installing or replacing any module. Verify that the relay module is properly addressed and configured within the panel programming before returning the system to service. Do not install this module in a wet or unprotected environment unless the enclosure is rated for such conditions.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 4XZMF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918589886770,"sku":"4XZMF","price":379.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/40dd2678acfd62adb64555f8f8105c8d.jpg?v=1791271318"},{"product_id":"fire-lite-alarms-by-honeywell-411ud-fire-communicator","title":"Fire-lite Alarms by Honeywell 411UD Fire Communicator","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL 411UD is a digital fire communicator designed for commercial and residential fire alarm systems. It features 4 input channels and Form-C relay output, allowing it to transmit alarm, supervisory, and trouble signals to a central monitoring station. The 411UD serves as a critical communication link between the fire alarm control panel and off-site monitoring infrastructure. Licensed fire alarm technicians and low-voltage electricians typically install and service this type of device as part of a complete fire detection and notification system.\u003c\/p\u003e\n\u003cp\u003eThe 411UD is suited for use in commercial buildings, multi-family residential properties, and institutional facilities where code-compliant fire alarm communication is required. It is installed in conjunction with fire alarm control panels and reporting systems that require a dedicated digital communicator for signal transmission to a UL-listed central station. The Form-C relay configuration supports standard supervised circuit wiring typical in fire alarm applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e4 input channels for monitoring multiple alarm zones or signal types\u003c\/li\u003e\n  \u003cli\u003eForm-C relay output for compatibility with supervised fire alarm wiring configurations\u003c\/li\u003e\n  \u003cli\u003eDesigned for digital signal transmission to central monitoring stations\u003c\/li\u003e\n  \u003cli\u003eSuitable for commercial and residential fire alarm system integration\u003c\/li\u003e\n  \u003cli\u003eSold individually as a single unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or direct installation unit for fire alarm control systems requiring a digital communicator with Form-C relay output and 4 input channels.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage electrician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and disconnect all power sources before wiring or replacing the communicator. Ensure all input channel and relay connections are verified and supervised per system design documentation before restoring power and conducting a full system test.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Digital Fire Communicator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Form-C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 411UD\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918604534066,"sku":"411UD","price":1705.25,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-fm996-l8-magnetic-door-holder","title":"Fire-lite Alarms by Honeywell FM996-L8 Magnetic Door Holder","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL FM996-L8 is a surface-mounted, wall-type magnetic door holder designed for fire alarm and life safety systems. This unit holds fire-rated doors in the open position during normal building operation and releases them automatically when the fire alarm system activates, allowing the door to close and contain the spread of smoke and fire. The quad-voltage design accommodates multiple input voltage configurations, making it a flexible choice for both new installations and retrofit applications. It is installed by licensed fire alarm technicians and electrical contractors following applicable life safety codes.\u003c\/p\u003e\n\u003cp\u003eThis magnetic door holder is intended for commercial and institutional applications where fire-rated corridor and stairwell doors must remain held open during normal use. The surface wall-mount configuration suits locations where a flush or floor-mount installation is not practical. When the fire alarm control panel sends a release signal, the electromagnet de-energizes and the door closes under spring or closer pressure. Typical install locations include office buildings, schools, healthcare facilities, and multi-family residential corridors.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSurface wall-mount design for straightforward installation on door frames or adjacent walls\u003c\/li\u003e\n  \u003cli\u003eQuad-voltage input compatibility reduces the need for separate power supplies across different system configurations\u003c\/li\u003e\n  \u003cli\u003eElectromagnetic hold-open mechanism releases automatically upon fire alarm activation\u003c\/li\u003e\n  \u003cli\u003eSold as a single unit, suitable for individual door applications\u003c\/li\u003e\n  \u003cli\u003ePart of the FIRE-LITE ALARMS BY HONEYWELL fire alarm accessory line for system-matched performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-install magnetic door holder for commercial fire alarm systems requiring a surface wall-mount quad-voltage electromagnetic hold-open device.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a qualified fire alarm technician or licensed electrician in accordance with NFPA 72, NFPA 80, and local Authority Having Jurisdiction requirements. Disconnect power to the fire alarm control panel circuit feeding the door holder before making any wiring connections. Verify door closer operation and door alignment before commissioning the holder. Do not bypass or disable the releasing circuit during testing without coordinating with the facility fire alarm system.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Magnetic Door Holders\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMount Type\u003c\/strong\u003e: Surface Wall Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Configuration\u003c\/strong\u003e: Quad Voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: FM996-L8\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918748385586,"sku":"FM996-L8","price":292.57,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-bg-12lra-pull-station","title":"Fire-lite Alarms by Honeywell BG-12LRA Pull Station","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BG-12LRA is a dual-action pull station designed for agent release applications in fire suppression systems. Dual-action operation requires two separate physical motions to activate, reducing the risk of accidental discharge. This type of device is typically wired into a fire alarm control panel and serves as a manual initiation point for suppression agent release in protected spaces. Installation and commissioning are performed by licensed fire alarm technicians or life safety contractors familiar with NFPA codes and local authority having jurisdiction requirements.\u003c\/p\u003e\u003cp\u003eThe BG-12LRA is suited for commercial and industrial environments where manual agent release pull stations are required as part of a total fire suppression system. Common install scenarios include server rooms, commercial kitchens, paint booths, and other occupancies protected by gaseous or chemical suppression agents. The dual-action design meets code requirements in applications where a single inadvertent pull must be prevented from triggering agent discharge.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDual-action activation reduces risk of accidental agent release\u003c\/li\u003e\n\u003cli\u003eDesigned for manual initiation in agent release fire suppression systems\u003c\/li\u003e\n\u003cli\u003eSold as a single unit (each)\u003c\/li\u003e\n\u003cli\u003eCompatible with fire alarm control panel wiring configurations standard to suppression release circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style manual pull station for use in commercial fire suppression agent release systems. No specific compatible panel model numbers or system families were provided in the available product data.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72, NFPA 17, NFPA 17A, and applicable local codes. Shut down and isolate the fire alarm control panel circuit before wiring or replacing the device. Coordinate with the suppression system designer or AHJ before final commissioning to confirm proper placement height and zone assignment. Do not test agent release circuits without confirming suppression agent discharge prevention measures are in place.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Pull Station\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivation Type\u003c\/strong\u003e: Dual Action\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Agent Release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BG-12LRA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918785577266,"sku":"BG-12LRA","price":691.49,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-w-gate-wireless-gateway","title":"Fire-lite Alarms by Honeywell W-GATE Wireless Gateway","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL W-GATE is a Litespeed wireless gateway designed for use in fire alarm and life safety systems. It serves as a communication bridge, enabling wireless signal transmission between compatible Litespeed devices and a fire alarm control panel. Licensed fire alarm technicians and low-voltage contractors are the primary installers of this component. The W-GATE is sold as a single unit and is classified as a fire control accessory, making it a key infrastructure component in wireless fire detection installations.\u003c\/p\u003e\u003cp\u003eThe W-GATE is suited for commercial and residential fire alarm applications where a wireless network architecture is required. It is typically installed in environments where running traditional wired signal paths is impractical or cost-prohibitive. The gateway integrates into a Litespeed wireless system topology, relaying device status and alarm data to the control panel. Installation scenarios include retrofit projects in existing structures and new construction where wireless zoning is specified by the system designer.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFunctions as a wireless gateway within the Litespeed fire alarm ecosystem\u003c\/li\u003e\n\u003cli\u003eEnables wireless communication between field devices and a fire alarm control panel\u003c\/li\u003e\n\u003cli\u003eClassified as a fire control accessory for system infrastructure use\u003c\/li\u003e\n\u003cli\u003eSold as a single unit for precise project quantity management\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use within FIRE-LITE ALARMS BY HONEYWELL Litespeed wireless fire alarm systems as a fire control accessory.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or qualified low-voltage contractor in accordance with NFPA 72 and applicable local codes. Power down or disconnect the fire alarm control panel before connecting or servicing the gateway. Follow the manufacturer wiring and placement diagrams for correct network registration and signal range. Do not install in locations subject to excessive moisture, vibration, or electromagnetic interference without verifying suitability.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: W-GATE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918835351858,"sku":"W-GATE","price":1233.14,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-ecc-50w-25v-audio-amplifier-module","title":"Fire-lite Alarms by Honeywell ECC-50W-25V Audio Amplifier Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL ECC-50W-25V is an audio amplifier module rated at 25 Vrms, designed for use in voice evacuation systems. It amplifies audio signals to drive speaker circuits in life-safety notification networks, delivering clear, intelligible audio output across covered zones. This module is a component-level device intended for installation by licensed fire alarm technicians working on commercial or institutional emergency communication systems. Its 25 Vrms output rating makes it suited for distributed speaker loads in standard voice evacuation configurations.\u003c\/p\u003e\u003cp\u003eThe ECC-50W-25V is applied in voice evacuation and emergency communication systems, typically found in commercial buildings, schools, healthcare facilities, and other occupancies requiring mass notification capability. It fits into panel-based architectures where audio amplification is handled at the module level, allowing technicians to match amplifier capacity to speaker load requirements zone by zone. Installation is performed during new construction or system upgrades where code-compliant voice evacuation is mandated.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e25 Vrms audio output for distributed speaker circuit compatibility\u003c\/li\u003e\n\u003cli\u003eDesigned for voice evacuation and emergency communication system applications\u003c\/li\u003e\n\u003cli\u003eModule-level amplification supports zone-by-zone system configuration\u003c\/li\u003e\n\u003cli\u003eSold as a single unit for precise capacity planning\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style replacement or expansion module for compatible voice evacuation panel systems requiring 25 Vrms audio amplification. No specific compatible model numbers were provided in the available product data.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and follow the panel manufacturer's lockout procedure before inserting or removing any module. Verify speaker circuit load calculations against the amplifier's rated output prior to commissioning. Do not exceed the rated Vrms output when connecting speaker loads.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 25 Vrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Category\u003c\/strong\u003e: Voice Evacuation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ECC-50W-25V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918849605938,"sku":"ECC-50W-25V","price":1547.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/06fe779a0f74824ba9956298e71a13e5.jpg?v=1791273828"},{"product_id":"fire-lite-alarms-by-honeywell-bb-55f-battery-back-box","title":"Fire-lite Alarms by Honeywell BB-55F Battery Back Box","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL BB-55F is a red battery back box designed to house backup battery assemblies in fire alarm control panel installations. This enclosure provides a dedicated, code-appropriate mounting solution for standby batteries, keeping the power source organized, protected, and separate from the main panel interior when additional battery capacity is required. Fire alarm system technicians and low-voltage electricians install this back box as part of a compliant fire alarm system build-out or retrofit. The red finish identifies the enclosure as part of the fire alarm system infrastructure at a glance.\u003c\/p\u003e\u003cp\u003eThe BB-55F is suited for use in commercial and residential fire alarm system applications where the primary control panel enclosure does not have sufficient internal space to accommodate standby batteries. It serves as an auxiliary enclosure that mounts adjacent to or near the main fire alarm control panel, extending the system's battery capacity housing. This is a common requirement on larger fire alarm systems or during panel upgrades where battery sizing increases beyond the original enclosure capacity.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eRed enclosure finish for quick visual identification as fire alarm system equipment\u003c\/li\u003e\n\u003cli\u003eDesigned to house standby backup batteries for fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eSold as an individual unit for flexible installation planning\u003c\/li\u003e\n\u003cli\u003eFunctions as a fire control accessory compatible with panel battery expansion needs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style battery back box accessory for fire alarm control panel installations requiring external standby battery housing.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or low-voltage electrician in accordance with NFPA 72 and applicable local codes. De-energize the fire alarm control panel and disconnect battery leads before working on battery connections or mounting the enclosure. Mount the back box securely to a structural surface using appropriate hardware rated for the enclosure weight when loaded. Verify battery polarity before reconnecting leads to avoid damage to the control panel or batteries.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Control Accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: Red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Package\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: BB-55F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67918998700338,"sku":"BB-55F","price":1276.89,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-alarms-by-honeywell-fhs-f-fireman-telephone-handset","title":"Fire-lite Alarms by Honeywell FHS-F Fireman Telephone Handset","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL FHS-F is a fireman telephone handset designed for use with fire alarm communication systems. It provides dedicated voice communication between building occupants, firefighters, and fire command centers during emergency operations. The FHS-F is a hardwired handset intended for installation at designated firefighter telephone jack stations throughout a structure. Licensed fire alarm technicians and life-safety contractors are the primary installers of this device. It is sold as a single unit and is classified as a fire alarm accessory.\u003c\/p\u003e\u003cp\u003eThe FHS-F is suited for commercial and high-rise residential buildings where fire codes require a firefighter telephone system as part of the overall fire alarm and emergency communication infrastructure. It is typically installed at elevator lobbies, stairwells, fire command centers, and other code-mandated locations. This handset plugs into or connects to a compatible telephone jack module wired back to the fire alarm control panel or dedicated firefighter telephone panel.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDedicated firefighter telephone handset for emergency voice communication\u003c\/li\u003e\n\u003cli\u003eDesigned for use with fire alarm telephone communication systems\u003c\/li\u003e\n\u003cli\u003eSingle-unit configuration suitable for jack-station deployment\u003c\/li\u003e\n\u003cli\u003eClassified as a fire alarm accessory for life-safety applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style replacement or supplemental handset for use with firefighter telephone systems in commercial fire alarm installations. Refer to the fire alarm panel or telephone module documentation to confirm handset compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and applicable local fire codes. Disconnect and de-energize the fire alarm system at the control panel before servicing any telephone jack stations or handset connections. Consult the system documentation and authority having jurisdiction (AHJ) for approved installation locations and wiring requirements. Do not substitute this handset in systems where it has not been listed or approved.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Fire Accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: FHS-F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67948614746418,"sku":"FHS-F","price":490.73,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-sd365t-iv-addressable-smoke-detector-with-thermostat-b300-6-b501-compatible","title":"Fire-Lite SD365T-IV Addressable Smoke Detector with Thermostat (B300-6\/B501 Compatible)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eFire-Lite SD365T-IV is an addressable photoelectric smoke detector with integrated thermostat and fixed-temperature heat sensing for use on compatible fire alarm control panels. The device operates from 15 to 32 VDC, transmits an analog representation of smoke density on the loop with one communication every five seconds, and has low quiescent and alarm currents for efficient loop loading. It fits B300 and B501 bases and tolerates wide humidity and air velocity ranges.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined photoelectric chamber and fixed 135Â°F (57.2Â°C) heat detector for multi-criteria detection\u003c\/li\u003e\n  \u003cli\u003eInput voltage 15â32 VDC; standby current 200 ÂµA @ 24 VDC; alarm current 2 mA @ 24 VDC; maximum current 4.5 mA @ 24 VDC\u003c\/li\u003e\n  \u003cli\u003eAddressable analog communications (one communication every 5 seconds), panel-controlled tri-color LEDs, tamper-resistance option, supports LiteSpeed and CLIP protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eAddressable photoelectric and fixed-temperature (135Â°F) heat sensor, 15â32 VDC operation, low standby current, compatible with B300 and B501 bases, supports LiteSpeed and CLIP\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SD365T-IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: SD365T-IV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Fire-Lite\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Addressable photoelectric smoke detector with integrated thermostat \/ fixed-temperature heat detector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat detector rating\u003c\/strong\u003e: 135Â°F (57.2Â°C) fixed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 15 to 32 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandby Current\u003c\/strong\u003e: 200 ÂµA @ 24 VDC (one communication every 5 seconds)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm Current\u003c\/strong\u003e: 2 mA @ 24 VDC (one communication every 5 seconds)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Current\u003c\/strong\u003e: 4.5 mA @ 24 VDC (one communication every 5 seconds)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e: One communication every 5 seconds (analog representation of smoke density)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtocols\u003c\/strong\u003e: LiteSpeed and CLIP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Panel-controlled tri-color LEDs (red\/green\/amber), steady or blinking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 32Â°F to 115Â°F (0Â°C to 47Â°C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e: 10% to 93% relative humidity, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Velocity\u003c\/strong\u003e: 0 to 4000 ft\/min (0 to 1219.2 m\/min)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstalled Height\u003c\/strong\u003e: 2.0 in (51 mm) installed on B300-6 base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiameter (on B300-6)\u003c\/strong\u003e: 6.2 in (156 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiameter (on B501)\u003c\/strong\u003e: 4.1 in (104 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 3.4 oz (95 g)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\/Base Compatibility\u003c\/strong\u003e: Fits B300 and B501 bases (plug-in)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eListings\u003c\/strong\u003e: UL 268 listed for open air protection; UL 521 listed for heat detectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTamper Resistance\u003c\/strong\u003e: Available (base dependent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Test\u003c\/strong\u003e: Magnet test supported (functional magnet)\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67949669908786,"sku":"SD365T-IV","price":614.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/6337894f7fe3bf6a112d2625520f7a70.png?v=1791697561"},{"product_id":"fire-lite-alarms-by-honeywell-ann-i-o-led-driver-module","title":"Fire-lite Alarms by Honeywell ANN-I\/O Led Driver Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE ALARMS BY HONEYWELL ANN-I\/O is an LED driver module designed for use as a remote annunciator in fire alarm systems. This module drives LED indicator circuits, allowing system status and alarm conditions to be displayed at a remote location away from the main fire alarm control panel. Licensed fire alarm technicians and low-voltage electrical contractors are the typical installers. The ANN-I\/O is sold individually as a single unit and is intended for integration into life-safety systems where remote status indication is required.\u003c\/p\u003e\u003cp\u003eThe ANN-I\/O is used in commercial and light commercial fire alarm installations where remote annunciation is necessary. Typical applications include buildings where the fire alarm control panel is not located at the primary point of entry or where code requires a remote annunciator at a monitored location. The module supports LED-based status displays, making it suitable for installations requiring clear visual indication of system conditions at secondary monitoring points.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFunctions as a remote annunciator LED driver module for fire alarm systems\u003c\/li\u003e\n\u003cli\u003eEnables remote LED status indication away from the main control panel\u003c\/li\u003e\n\u003cli\u003eSold as a single unit for straightforward procurement and replacement\u003c\/li\u003e\n\u003cli\u003eDesigned for integration into life-safety and fire alarm panel architectures\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style remote annunciator LED driver module for use with compatible FIRE-LITE ALARMS BY HONEYWELL fire alarm control panel systems.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or qualified low-voltage electrical contractor in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and follow lockout\/tagout procedures before servicing or connecting any modules. Verify all wiring connections are secure and that the module is properly seated before restoring power. Final commissioning and testing must comply with the authority having jurisdiction.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Remote Annunciator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e: Each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity Per Unit\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE ALARMS BY HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ANN-I\/O\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":67951513534770,"sku":"ANN-I\/O","price":1275.7,"currency_code":"USD","in_stock":false}]},{"product_id":"fire-lite-tl-1055-ir-test-lamp-heat-detector","title":"Fire-lite TL-1055 Ir Test Lamp Heat Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE TL-1055 is an infrared test lamp designed for field testing of heat detectors. It provides a controlled IR light source that allows fire alarm technicians to verify detector response without activating a live fire condition. The TL-1055 is a purpose-built service tool used during installation verification, periodic testing, and troubleshooting of compatible fixed-temperature and rate-of-rise heat detector units. Its compact lamp form factor makes it practical for use on elevated ceilings and in confined spaces where detector heads are typically mounted.\u003c\/p\u003e\n\u003cp\u003eThe TL-1055 is intended for use by licensed fire alarm technicians and fire protection contractors performing inspection, testing, and maintenance work on commercial and residential fire alarm systems. It is specifically referenced for testing the FS18X and FS20X series heat detectors. This tool supports compliance with NFPA 72 testing requirements that mandate periodic functional verification of all detection devices on a fire alarm system.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eInfrared light source designed to stimulate heat detector response during testing\u003c\/li\u003e\n  \u003cli\u003eCompatible with FS18X and FS20X series heat detectors per manufacturer specification\u003c\/li\u003e\n  \u003cli\u003eSupports NFPA 72 periodic inspection and testing requirements\u003c\/li\u003e\n  \u003cli\u003eCompact lamp form factor suited for overhead and ceiling-mounted detector access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eSpecified for testing the FS18X and FS20X series heat detectors as stated in manufacturer documentation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eThis device is a test instrument and should be operated by qualified fire alarm service technicians in accordance with NFPA 72 and applicable local codes. Before conducting detector tests, notify the monitoring station and building occupants to prevent accidental emergency response dispatch. Follow the detector manufacturer's testing procedure and document all test results as required by the authority having jurisdiction.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: IR Test Lamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: TL-1055\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68050205606194,"sku":"TL-1055","price":6546.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/5c33bc0d6dd3293fc21223a2e4328123.jpg?v=1792985408"},{"product_id":"fire-lite-mr-101-t-multi-voltage-relay-track-mounted","title":"Fire-Lite MR-101\/T Multi-Voltage Relay (Track Mounted)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eFire-Lite MR-101\/T is a multi-voltage SPDT relay module designed for track mounting in standard cabinets. The relay supports energizing from 18â35 VDC or VAC and from 120 VAC or 230 VAC, and provides an LED indicator for status. When used with an optional IP\/POTS communicator card it can report alarms, troubles, and AC loss and permit remote programming or interrogation of the control panel. The unit is UL recognized and rated for 10,000,000 mechanical operations.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSPDT relay with multi-voltage operation: 18â35 VDC\/VAC, 120 VAC, and 230 VAC\u003c\/li\u003e\n  \u003cli\u003eTrack-mounted module with hardware for installation in standard cabinets; single, dual, or triple modules split from a 4-position master\u003c\/li\u003e\n  \u003cli\u003eUL recognized and UL listed as a control unit accessory; relays rated for 10,000,000 mechanical operations with a red LED per relay position\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eTrack-mounted SPDT relay, multi-voltage operation, LED indicator, optional IP\/POTS communicator support, UL recognized\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MR-101\/T\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Fire-Lite\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell International, Inc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MR-101\/T\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eADI Part Number\u003c\/strong\u003e: 8K-MR101T\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSES Number\u003c\/strong\u003e: FL MR-101\/T\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: MR\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: SPDT relay, multi-voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact Type\u003c\/strong\u003e: SPDT (Single Pole Double Throw)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 18 to 35 VDC or VAC; 120 VAC; 230 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Track mounted\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Configuration\u003c\/strong\u003e: Single, dual, or triple modules split from 4-position master\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndicator\u003c\/strong\u003e: Red LED per relay position\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL Listing\u003c\/strong\u003e: Listed as control unit accessory; relays are UL recognized\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Operations Rating\u003c\/strong\u003e: 10,000,000 operations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuty Rating\u003c\/strong\u003e: Continuous duty\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Options\u003c\/strong\u003e: Dust-proof metal enclosure versions available (MR-101\/CR and MR-201\/CR)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 3.00 in (L) x 2.10 in (W) x 1.50 in (H)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: US\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSector\u003c\/strong\u003e: Fire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: HVAC systems, temperature control systems, fire alarm systems, security systems, energy management systems, lighting control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68055107731762,"sku":"MR-101\/T","price":118.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/e29c4f32bcc6eee88695e24856b4d370.jpg?v=1793003775"},{"product_id":"fire-lite-b224rb-iv-detector-base-with-relay-ivory","title":"Fire-lite B224RB-IV Detector Base with Relay Ivory","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE B224RB-IV is a plug-in detector relay base designed for use with 200 Series fire detection devices. It provides a single Form C contact relay that enables control of auxiliary functions tied to the fire alarm system. Common applications include door closure activation and elevator recall. The base accepts a plug-in detector and integrates directly into the wiring loop without additional hardware. Fire alarm technicians and life-safety contractors install this base as part of a compliant detection layout. Its relay output allows the system to trigger building control functions automatically upon alarm activation.\u003c\/p\u003e\n\u003cp\u003eThe B224RB-IV is suited for commercial and light-industrial fire alarm installations where auxiliary device control is required at the detector level. It is used in applications where door holders, elevator controls, or other building systems must respond to a fire alarm signal. The plug-in design simplifies installation and detector replacement without disturbing field wiring. The ivory finish is standard for commercial fire alarm installations.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle Form C contact relay for auxiliary function control\u003c\/li\u003e\n  \u003cli\u003eCompatible with 200 Series plug-in detectors\u003c\/li\u003e\n  \u003cli\u003eSupports door closure and elevator recall applications\u003c\/li\u003e\n  \u003cli\u003ePlug-in base design for simplified detector removal and replacement\u003c\/li\u003e\n  \u003cli\u003eIvory finish suited for standard commercial installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with FIRE-LITE 200 Series detectors. Consult the system documentation to confirm compatibility with the specific detector model and fire alarm control panel in use.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel and follow lockout procedures before wiring or mounting the base. Verify that the Form C relay output is wired correctly to the intended auxiliary device before restoring system power. Do not substitute wiring or bypass the relay contact without engineering review.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Detector Base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Type\u003c\/strong\u003e: Single Form C contact\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: Ivory\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: MX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: B224RB-IV\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68055621108018,"sku":"B224RB-IV","price":160.22,"currency_code":"USD","in_stock":false}]},{"product_id":"fire-lite-osp-001-ftdi-cable-1-5-m","title":"Fire-Lite OSP-001 FTDI Cable (1.5 m)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eFire-Lite OSP-001 is an FTDI USB-to-serial programming and data cable by Fire-Lite, featuring a 1.5 m length for device communication. The cable uses an FTDI chipset to provide USB-to-serial conversion for programming and data transfer with Fire-Lite alarm system devices. It is documented as compatible with Fire-Lite alarm communication and referenced with use on Xtralis devices and smoke detector interfaces.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFTDI USB-to-serial cable with FTDI chipset for programming and data transfer\u003c\/li\u003e\n  \u003cli\u003eCable length: 1.5 m (approximately 5 feet \/ ~59.06 in) for convenient device connection\u003c\/li\u003e\n  \u003cli\u003eIntended for communication and programming of Fire-Lite alarm system devices; referenced as compatible with Xtralis devices and smoke detector interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eFTDI USB-to-serial programming\/data cable, 1.5 m length, for Fire-Lite alarm system communication\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: OSP-001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Fire-Lite\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: OSP-001\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: FTDI USB-to-serial cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length\u003c\/strong\u003e: 1.5 m (approximately 59.06 in)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChipset\u003c\/strong\u003e: FTDI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 884965002633\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlternate Part Numbers\u003c\/strong\u003e: FILOSP001; OSP001; FL OSP-001\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e: Fire-Lite alarm system devices; referenced compatibility with Xtralis devices and smoke detector interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68067653386546,"sku":"OSP-001","price":215.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/4d992fe510afc34a9117aeb3d5961d6d.jpg?v=1793079157"},{"product_id":"fire-lite-mcbl-7-phone-cable-ms-9050-series","title":"Fire-lite MCBL-7 Phone Cable MS-9050 Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE MCBL-7 is a replacement phone cable designed for use with Fire-Lite MS-9050 series fire alarm control panels. This 7-foot cord provides the physical connection between the control panel and a remote phone handset or ancillary communication device. It is a straightforward, OEM-specified cable intended for use by licensed fire alarm technicians during installation, service, or replacement work on compatible Fire-Lite systems. Having the correct cable on hand reduces downtime during panel commissioning or field service calls.\u003c\/p\u003e\n\u003cp\u003eThis cable is used in commercial fire alarm installations where the MS-9050 series panel is deployed. It supports phone device connectivity within the panel's communication infrastructure. The MCBL-7 is typically installed or replaced by fire alarm technicians during initial system setup or routine maintenance. Its 7-foot length suits standard panel-to-handset distances found in typical fire alarm closet or riser room installations.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e7-foot cable length suits standard MS-9050 series panel installations\u003c\/li\u003e\n  \u003cli\u003eOEM-specified phone cable for Fire-Lite MS-9050 series fire alarm control panels\u003c\/li\u003e\n  \u003cli\u003eSupports phone device connectivity at the panel\u003c\/li\u003e\n  \u003cli\u003eDomestic product  -  country of origin: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with the Fire-Lite MS-9050 series fire alarm control panels as specified by the manufacturer.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with applicable NFPA 72 requirements and local authority having jurisdiction (AHJ) guidelines. Power down or place the panel in test mode before disconnecting or replacing any cables to avoid nuisance alarms or panel faults. Verify cable seating at both connection points before restoring panel operation.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length\u003c\/strong\u003e: 7 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Phone Cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDevice Supported\u003c\/strong\u003e: Phone\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: MS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MCBL-7\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68075449090354,"sku":"MCBL-7","price":38.17,"currency_code":"USD","in_stock":true}]},{"product_id":"fire-lite-ecc-loc-local-operator-console-pack-1","title":"Fire-Lite ECC-LOC Local Operator Console (Pack 1)","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Fire-Lite ECC-LOC is a local operator console (MPN ECC-LOC) for Fire-Lite fire alarm systems, manufactured by Honeywell International, Inc. It provides on-site control and status interface for compatible alarm panels. The unit is suitable for integration in building fire alarm installations and maintenance workflows.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLocal operator console for Fire-Lite fire alarm systems, model ECC-LOC\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell International, Inc; MPN: ECC-LOC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eLocal operator interface for Fire-Lite alarm systems, model ECC-LOC, manufactured by Honeywell.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ECC-LOC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Fire-Lite\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell International, Inc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ECC-LOC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 783008112035\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEAN\u003c\/strong\u003e: 0783008112035\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eASIN\u003c\/strong\u003e: B00IPQX91I\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Fire alarm local operator console (accessory)\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":68075670700338,"sku":"ECC-LOC","price":6547.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/109e1c0b843360f010d750b1b74b5526.jpg?v=1793107565"}],"url":"https:\/\/voomisupply.com\/collections\/fire-lite.oembed?page=3","provider":"Voomi Supply","version":"1.0","type":"link"}