{"title":"FIRE-LITE","description":null,"products":[{"product_id":"fire-lite-h365-addressable-heat-detector-with-base","title":"Fire-lite h365 Addressable Heat Detector with Base","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE h365 is an addressable heat detector designed for use in intelligent fire alarm systems. It monitors for abnormal temperature conditions using both fixed temperature and rate-of-rise detection technologies, providing reliable response to rapid and gradual heat buildup scenarios. The detector communicates with the control panel over a two-wire signaling line circuit and occupies a single device address, enabling precise alarm location identification across the protected area. A low-profile housing keeps the unit unobtrusive in finished interiors, and the sensing chamber is designed to resist contamination for stable long-term performance. The unit ships with its mounting base included.\u003c\/p\u003e\n\u003cp\u003eThe h365 is suited for commercial and light industrial applications where intelligent heat detection is required. Typical installations include office buildings, educational facilities, hospitality environments, and industrial spaces. It integrates into intelligent life safety infrastructures that use addressable signaling line circuits, allowing the control panel to pinpoint the exact device location at alarm. The detector fits into a standard base that supports secure locking and straightforward removal during routine inspection or maintenance cycles.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDual detection technology: fixed temperature and rate-of-rise sensing for response to both slow and fast heat buildup\u003c\/li\u003e\n  \u003cli\u003eAddressable operation over a two-wire signaling line circuit with single device address assignment\u003c\/li\u003e\n  \u003cli\u003eLow-profile housing suitable for finished commercial and institutional interiors\u003c\/li\u003e\n  \u003cli\u003eContamination-resistant sensing chamber supports stable long-term operation\u003c\/li\u003e\n  \u003cli\u003eIntegrated status indicator provides clear standby and alarm state visibility\u003c\/li\u003e\n  \u003cli\u003eIncludes mounting base with secure locking and tool-assisted removal for maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style addressable heat detector for use with intelligent fire alarm control panels that support two-wire signaling line circuit devices.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician in accordance with NFPA 72 and all applicable local codes. De-energize the signaling line circuit at the control panel before connecting or removing the detector. Assign the device address according to the system documentation before mounting the detector into the base. Verify normal standby status on the control panel after installation and before returning the system to service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection Technology\u003c\/strong\u003e: Fixed temperature and rate-of-rise\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Type\u003c\/strong\u003e: Two-wire signaling line circuit (SLC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing\u003c\/strong\u003e: Single device address, addressable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Profile\u003c\/strong\u003e: Low-profile\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase\u003c\/strong\u003e: Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: h365\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51524572053810,"sku":"H365","price":100.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/d020a6cf0f3ddf9ab8c439e0d533c0ec.jpg?v=1785452045"},{"product_id":"fire-lite-sd365r-addressable-photoelectric-smoke-detector","title":"Fire-lite sd365r Addressable Photoelectric Smoke Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE sd365r is an addressable, plug-in photoelectric smoke detector with remote test capability, designed for use with DNR and DNRW remote test accessories. It is part of the SD365 Series, which features an enhanced optical sensing chamber engineered to detect smoke from a wide range of combustion sources in compliance with current fire code standards. The sd365r is suited for installation in commercial and residential life-safety systems where addressable detection and remote testing access are required. Licensed fire alarm technicians and low-voltage contractors handle installation and commissioning.\u003c\/p\u003e\u003cp\u003eThe sd365r fits into addressable fire alarm systems using the LiteSpeed protocol or CLIP protocol depending on the finish selected. The white finish version supports LiteSpeed protocol only, while the ivory finish version supports both CLIP and LiteSpeed protocols. This makes the sd365r adaptable across a range of addressable fire alarm control panel configurations. It is typically installed in ceilings of commercial buildings, schools, healthcare facilities, and multi-unit residential structures where code requires addressable detection with remote test functionality.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAddressable plug-in design for compatibility with addressable fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eEnhanced optical sensing chamber for detection of smoke from a broad range of combustion sources\u003c\/li\u003e\n\u003cli\u003eRemote test capability for use with DNR and DNRW remote test accessories\u003c\/li\u003e\n\u003cli\u003eAvailable in white (LiteSpeed protocol only) and ivory (CLIP and LiteSpeed protocols)\u003c\/li\u003e\n\u003cli\u003eContemporary low-profile design suitable for visible installation in finished spaces\u003c\/li\u003e\n\u003cli\u003ePart of the SD365 Series, which includes photo-only and photo-thermal variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eThe sd365r is designed for use with DNR and DNRW remote test accessories and is compatible with addressable fire alarm systems supporting LiteSpeed protocol (white finish) or both CLIP and LiteSpeed protocols (ivory finish).\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. De-energize the fire alarm control panel circuit before connecting or removing the detector head from its base. Verify protocol compatibility between the detector finish selected and the addressable control panel before installation. Follow the manufacturer wiring and address-setting documentation provided with the panel and detector.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Type\u003c\/strong\u003e: Photoelectric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: LiteSpeed (white); CLIP and LiteSpeed (ivory)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-in addressable base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Test\u003c\/strong\u003e: Compatible with DNR and DNRW accessories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SD365\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sd365r\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525244584242,"sku":"SD365R","price":120.37,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/e00e0851f0b393109f975b9ca0c7fbea.jpg?v=1785468311"},{"product_id":"fire-lite-sb-io-surface-back-box-for-bg-12-pull-station","title":"Fire-lite sb-io Surface Back Box for BG-12 Pull Station","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe FIRE-LITE sb-io is a surface-mount back box designed for use with the BG-12 manual pull station. This enclosure provides a proper mounting surface for the pull station in locations where flush or recessed installation is not practical. Constructed as a plastic enclosure, the sb-io supports both indoor and outdoor installation environments. Fire alarm technicians and life safety contractors install this back box as part of a code-compliant pull station assembly, ensuring the BG-12 is securely mounted and properly positioned for occupant access.\u003c\/p\u003e\n\u003cp\u003eThe sb-io is suited for surface-mount applications in commercial and light industrial facilities where the BG-12 manual pull station is part of the fire alarm system. Typical installations include locations with exposed conduit runs or masonry walls where recessed mounting is not feasible. The enclosure accommodates indoor and outdoor environments, making it a practical solution for covered exterior locations such as building egress points, stairwells, and covered walkways.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSurface-mount design for locations where flush installation is not practical\u003c\/li\u003e\n  \u003cli\u003eCompatible with the BG-12 manual pull station\u003c\/li\u003e\n  \u003cli\u003eRated for both indoor and outdoor installation environments\u003c\/li\u003e\n  \u003cli\u003ePlastic construction for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eSupports code-compliant pull station mounting per NFPA 72 installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with the FIRE-LITE BG-12 manual pull station as a surface-mount back box enclosure.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a licensed fire alarm technician or qualified life safety contractor in accordance with NFPA 72 and applicable local codes. Disable the fire alarm control panel or place it in test mode before beginning installation to prevent unwanted alarms. Secure the back box to the mounting surface before attaching the BG-12 pull station, and verify all conduit entries are properly sealed for outdoor installations.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Type\u003c\/strong\u003e: Surface mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment Rating\u003c\/strong\u003e: Indoor and outdoor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Plastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Device\u003c\/strong\u003e: BG-12 manual pull station\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sb-io\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525369168178,"sku":"SB-IO","price":30.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/17efe2c218509eb855bac4768204dba9.jpg?v=1785471915"},{"product_id":"fire-lite-flt-mdf-300-dual-addressable-monitor-module","title":"Fire-lite flt-mdf-300 Dual Addressable Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE flt-mdf-300 is a dual addressable monitor module designed for intelligent, two-wire fire alarm systems. It supervises and monitors initiating device circuits (IDCs), supporting dry-contact input devices such as conventional heat detectors, manual pull stations, and two-wire smoke detectors. The module provides two independent IDCs at two separate, consecutive addresses on the signaling line circuit. A single panel-controlled LED provides local status indication. Licensed fire alarm technicians and low-voltage contractors install this module as part of addressable system expansions or new construction fire alarm installations.\u003c\/p\u003e\u003cp\u003eThis module is suited for commercial and light industrial fire alarm applications where intelligent addressable control panels are specified. It is used to bring conventional initiating devices into an addressable system architecture, allowing each circuit to report independently to the fire alarm control panel. Typical installations include office buildings, schools, healthcare facilities, and other occupancies requiring addressable detection with multiple supervised input zones.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTwo independent two-wire initiating device circuits (IDCs) at two consecutive addresses\u003c\/li\u003e\n\u003cli\u003eMonitors normally open contact fire alarm and supervisory devices\u003c\/li\u003e\n\u003cli\u003eCompatible with intelligent, two-wire addressable fire alarm control panels\u003c\/li\u003e\n\u003cli\u003eSupports conventional heat detectors, manual pull stations, and two-wire smoke detectors\u003c\/li\u003e\n\u003cli\u003eSingle panel-controlled LED for local status indication\u003c\/li\u003e\n\u003cli\u003eDual-address architecture allows each IDC to report independently to the panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use with intelligent, two-wire addressable fire alarm control panels that accept dual monitor module devices. Consult the fire alarm control panel listing and system design documents to confirm address capacity and module compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician or low-voltage contractor in accordance with NFPA 72 and all applicable local codes. Disconnect power from the fire alarm control panel and verify the signaling line circuit is de-energized before wiring the module. Follow the manufacturer wiring diagram for correct IDC and SLC connections. After installation, perform a full point-to-point test to verify both addresses report correctly to the control panel.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: Dual Addressable Monitor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitiating Device Circuits\u003c\/strong\u003e: 2 independent two-wire IDCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Configuration\u003c\/strong\u003e: Two separate, consecutive addresses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Input Type\u003c\/strong\u003e: Normally open dry-contact devices and two-wire smoke detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e: Single panel-controlled LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003e: Intelligent two-wire addressable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: flt-mdf-300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51525490868530,"sku":"FLT-MDF-300","price":223.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/adcb0c21df469ca11159587af9e43dc9.jpg?v=1785475467"},{"product_id":"fire-lite-sd365-addressable-photoelectric-smoke-detector","title":"Fire-lite sd365 Addressable Photoelectric Smoke Detector","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe FIRE-LITE sd365 is an addressable, plug-in photoelectric smoke detector built for LiteSpeed-compatible fire alarm systems. It uses an enhanced optical sensing chamber engineered to detect smoke from a wide range of combustion sources, meeting more stringent code standards than previous-generation devices. The low-profile, contemporary housing is designed to blend into commercial ceiling environments while maintaining reliable detection performance. Licensed fire alarm technicians and life-safety contractors are the typical installing trades for this device.\u003c\/p\u003e\u003cp\u003eThe sd365 is intended for addressable fire alarm systems running the LiteSpeed protocol. Its intelligent plug-in design simplifies field replacement and reduces installation time on new construction and retrofit projects alike. The detector is suited for commercial and light industrial occupancies where addressable loop architecture is specified by the authority having jurisdiction.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eAddressable plug-in design for fast field replacement without rewiring\u003c\/li\u003e\n\u003cli\u003eEnhanced optical sensing chamber detects smoke from a wide range of combustion sources\u003c\/li\u003e\n\u003cli\u003eCompatible with LiteSpeed addressable fire alarm systems only\u003c\/li\u003e\n\u003cli\u003eModern, low-profile housing engineered for aesthetic and functional fit in commercial environments\u003c\/li\u003e\n\u003cli\u003eEngineered to meet more stringent smoke detection code standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for LiteSpeed-compatible addressable fire alarm systems. This detector replaces the SD355.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed fire alarm technician in accordance with NFPA 72 and local authority having jurisdiction requirements. Power down and isolate the addressable loop before removing or inserting the detector base. Do not install in environments outside the detector's rated operating conditions, and verify address programming matches the panel configuration before returning the system to service.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Technology\u003c\/strong\u003e: Photoelectric optical sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: LiteSpeed addressable only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: FIRE-LITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: sd365\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":51620983570738,"sku":"SD365","price":99.22,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/voomisupply.com\/collections\/fire-lite.oembed","provider":"Voomi Supply","version":"1.0","type":"link"}